Numerical and experimental investigations on thermal management for data center with cold aisle containment configuration
Author
Abstract
Suggested Citation
DOI: 10.1016/j.apenergy.2021.118213
Download full text from publisher
As the access to this document is restricted, you may want to search for a different version of it.
References listed on IDEAS
- Han, Zongwei & Zhang, Yanqing & Meng, Xin & Liu, Qiankun & Li, Weiliang & Han, Yu & Zhang, Yanhong, 2016. "Simulation study on the operating characteristics of the heat pipe for combined evaporative cooling of computer room air-conditioning system," Energy, Elsevier, vol. 98(C), pages 15-25.
- Han, Zongwei & Xue, Da & Wei, Haotian & Ji, Qiang & Sun, Xiaoqing & Li, Xiuming, 2021. "Study on operation strategy of evaporative cooling composite air conditioning system in data center," Renewable Energy, Elsevier, vol. 177(C), pages 1147-1160.
- Gupta, Rohit & Asgari, Sahar & Moazamigoodarzi, Hosein & Pal, Souvik & Puri, Ishwar K., 2020. "Cooling architecture selection for air-cooled Data Centers by minimizing exergy destruction," Energy, Elsevier, vol. 201(C).
- Han, Zongwei & Ji, Qiang & Wei, Haotian & Xue, Da & Sun, Xiaoqing & Zhang, Xueping & Li, Xiuming, 2020. "Simulation study on performance of data center air-conditioning system with novel evaporative condenser," Energy, Elsevier, vol. 210(C).
- Sun, Xiaoqin & Zhang, Quan & Medina, Mario A. & Liao, Shuguang, 2015. "Performance of a free-air cooling system for telecommunications base stations using phase change materials (PCMs): In-situ tests," Applied Energy, Elsevier, vol. 147(C), pages 325-334.
- Tradat, Mohammad I. & Manaserh, Yaman “Mohammad Ali” & Sammakia, Bahgat G. & Hoang, Cong Hiep & Alissa, Husam A., 2021. "An experimental and numerical investigation of novel solution for energy management enhancement in data centers using underfloor plenum porous obstructions," Applied Energy, Elsevier, vol. 289(C).
- Mitchell-Jackson, J. & Koomey, J.G. & Nordman, B. & Blazek, M., 2003. "Data center power requirements: measurements from Silicon Valley," Energy, Elsevier, vol. 28(8), pages 837-850.
- Bulut, Hüsamettin & Aktacir, Mehmet Azmi, 2011. "Determination of free cooling potential: A case study for Istanbul, Turkey," Applied Energy, Elsevier, vol. 88(3), pages 680-689, March.
- Harby, K. & Gebaly, Doaa R. & Koura, Nader S. & Hassan, Mohamed S., 2016. "Performance improvement of vapor compression cooling systems using evaporative condenser: An overview," Renewable and Sustainable Energy Reviews, Elsevier, vol. 58(C), pages 347-360.
- Rong, Huigui & Zhang, Haomin & Xiao, Sheng & Li, Canbing & Hu, Chunhua, 2016. "Optimizing energy consumption for data centers," Renewable and Sustainable Energy Reviews, Elsevier, vol. 58(C), pages 674-691.
- Liu, Yuting & Yang, Xu & Li, Junming & Zhao, Xudong, 2018. "Energy savings of hybrid dew-point evaporative cooler and micro-channel separated heat pipe cooling systems for computer data centers," Energy, Elsevier, vol. 163(C), pages 629-640.
- Cho, Jinkyun & Kim, Yundeok, 2016. "Improving energy efficiency of dedicated cooling system and its contribution towards meeting an energy-optimized data center," Applied Energy, Elsevier, vol. 165(C), pages 967-982.
Citations
Citations are extracted by the CitEc Project, subscribe to its RSS feed for this item.
Cited by:
- Xiaofei Huang & Junwei Yan & Xuan Zhou & Yixin Wu & Shichen Hu, 2023. "Cooling Technologies for Internet Data Center in China: Principle, Energy Efficiency, and Applications," Energies, MDPI, vol. 16(20), pages 1-31, October.
- Weijian Ding & Behzad Ebrahimi & Byoung-Do Kim & Connie L. Devenport & Amy E. Childress, 2024. "Analysis of Anthropogenic Waste Heat Emission from an Academic Data Center," Energies, MDPI, vol. 17(8), pages 1-20, April.
Most related items
These are the items that most often cite the same works as this one and are cited by the same works as this one.- Li, Chao & Mao, Ruiyong & Wang, Yong & Zhang, Jun & Lan, Jiang & Zhang, Zujing, 2024. "Experimental study on direct evaporative cooling for free cooling of data centers," Energy, Elsevier, vol. 288(C).
- Han, Zongwei & Ji, Qiang & Wei, Haotian & Xue, Da & Sun, Xiaoqing & Zhang, Xueping & Li, Xiuming, 2020. "Simulation study on performance of data center air-conditioning system with novel evaporative condenser," Energy, Elsevier, vol. 210(C).
- Sun, Xiaoqing & Zhang, Ce & Han, Zongwei & Dong, Jiaxiang & Zhang, Yiqi & Li, Mengyi & Li, Xiuming & Wang, Qinghai & Wen, Zhenwu & Zheng, Baoli, 2023. "Experimental study on a novel pump-driven heat pipe/vapor compression system for rack-level cooling of data centers," Energy, Elsevier, vol. 274(C).
- Shao, Shuangquan & Liu, Haichao & Zhang, Hainan & Tian, Changqing, 2019. "Experimental investigation on a loop thermosyphon with evaporative condenser for free cooling of data centers," Energy, Elsevier, vol. 185(C), pages 829-836.
- Hu, Zhi-Hua & Zheng, Yu-Xin & Wang, You-Gan, 2022. "Packing computing servers into the vessel of an underwater data center considering cooling efficiency," Applied Energy, Elsevier, vol. 314(C).
- Habibi Khalaj, Ali & Scherer, Thomas & K. Halgamuge, Saman, 2016. "Energy, environmental and economical saving potential of data centers with various economizers across Australia," Applied Energy, Elsevier, vol. 183(C), pages 1528-1549.
- Cho, Jinkyun & Park, Beungyong & Jang, Seungmin, 2022. "Development of an independent modular air containment system for high-density data centers: Experimental investigation of row-based cooling performance and PUE," Energy, Elsevier, vol. 258(C).
- Selorm Kwaku Anka & Nicholas Lamptey Boafo & Kwesi Mensah & Samuel Boahen & Kwang Ho Lee & Jong Min Choi, 2022. "Study on the Performance of a Newly Designed Cooling System Utilizing Dam Water for Internet Data Centers," Energies, MDPI, vol. 15(24), pages 1-19, December.
- Cheng Liu & Hang Yu, 2021. "Evaluation and Optimization of a Two-Phase Liquid-Immersion Cooling System for Data Centers," Energies, MDPI, vol. 14(5), pages 1-21, March.
- Hadeed Ashraf & Muhammad Sultan & Uzair Sajjad & Muhammad Wakil Shahzad & Muhammad Farooq & Sobhy M. Ibrahim & Muhammad Usman Khan & Muhammad Ahmad Jamil, 2022. "Potential Investigation of Membrane Energy Recovery Ventilators for the Management of Building Air-Conditioning Loads," Energies, MDPI, vol. 15(6), pages 1-23, March.
- Zhang, Yiqi & Li, Mengyi & Dong, Jiaxiang & Zhang, Ce & Li, Xiuming & Han, Zongwei, 2023. "Study on the impacts of refrigerant leakage on the performance and reliability of datacenter composite air conditioning system," Energy, Elsevier, vol. 284(C).
- Zhang, Xueping & Li, Gui & Han, Zongwei & Yang, Ziwei & Bi, Weiqiang & Li, Xiuming & Yang, Lingyan, 2023. "Study on the influence of buried pipe fault on the operation of ground source heat pump system," Renewable Energy, Elsevier, vol. 210(C), pages 12-25.
- Cui, Yuanlong & Zhu, Jie & Zoras, Stamatis & Liu, Lin, 2021. "Review of the recent advances in dew point evaporative cooling technology: 3E (energy, economic and environmental) assessments," Renewable and Sustainable Energy Reviews, Elsevier, vol. 148(C).
- Heran Jing & Zhenhua Quan & Yaohua Zhao & Lincheng Wang & Ruyang Ren & Ruixue Dong & Yuting Wu, 2022. "Experimental Investigation of Heat Transfer and Flow Characteristics of Split Natural Cooling System for Data Center Based on Micro Heat Pipe Array," Energies, MDPI, vol. 15(12), pages 1-22, June.
- Zhou, Jing & Kanbur, Baris Burak & Le, Duc Van & Tan, Rui & Duan, Fei, 2023. "Multi-criteria assessments of increasing supply air temperature in tropical data center," Energy, Elsevier, vol. 271(C).
- Manaserh, Yaman M. & Tradat, Mohammad I. & Bani-Hani, Dana & Alfallah, Aseel & Sammakia, Bahgat G. & Nemati, Kourosh & Seymour, Mark J., 2022. "Machine learning assisted development of IT equipment compact models for data centers energy planning," Applied Energy, Elsevier, vol. 305(C).
- He, Wei & Ding, Su & Zhang, Jifang & Pei, Chenchen & Zhang, Zhiheng & Wang, Yulin & Li, Hailong, 2021. "Performance optimization of server water cooling system based on minimum energy consumption analysis," Applied Energy, Elsevier, vol. 303(C).
- Cho, Jinkyun & Kim, Youngmo, 2021. "Development of modular air containment system: Thermal performance optimization of row-based cooling for high-density data centers," Energy, Elsevier, vol. 231(C).
- Kim, Donghun & Braun, James E., 2020. "Model predictive control for supervising multiple rooftop unit economizers to fully leverage free cooling energy resource," Applied Energy, Elsevier, vol. 275(C).
- Guizzi, Giuseppe Leo & Manno, Michele, 2012. "Fuel cell-based cogeneration system covering data centers’ energy needs," Energy, Elsevier, vol. 41(1), pages 56-64.
More about this item
Keywords
Data center; Airflow management; Rack cooling index; Return temperature index; Supply heat index; CFD simulation;All these keywords.
Statistics
Access and download statisticsCorrections
All material on this site has been provided by the respective publishers and authors. You can help correct errors and omissions. When requesting a correction, please mention this item's handle: RePEc:eee:appene:v:307:y:2022:i:c:s030626192101480x. See general information about how to correct material in RePEc.
If you have authored this item and are not yet registered with RePEc, we encourage you to do it here. This allows to link your profile to this item. It also allows you to accept potential citations to this item that we are uncertain about.
If CitEc recognized a bibliographic reference but did not link an item in RePEc to it, you can help with this form .
If you know of missing items citing this one, you can help us creating those links by adding the relevant references in the same way as above, for each refering item. If you are a registered author of this item, you may also want to check the "citations" tab in your RePEc Author Service profile, as there may be some citations waiting for confirmation.
For technical questions regarding this item, or to correct its authors, title, abstract, bibliographic or download information, contact: Catherine Liu (email available below). General contact details of provider: http://www.elsevier.com/wps/find/journaldescription.cws_home/405891/description#description .
Please note that corrections may take a couple of weeks to filter through the various RePEc services.