IDEAS home Printed from https://ideas.repec.org/a/eee/rensus/v192y2024ics1364032123010675.html
   My bibliography  Save this article

High-efficiency heating and cooling technology with embedded pipes in buildings and underground structures: A review

Author

Listed:
  • Chen, Zhaoxin
  • Li, Jiaxuan
  • Tang, Guoqiang
  • Zhang, Jiahao
  • Zhang, Donghai
  • Gao, Penghui

Abstract

The thermally activated system utilizes heat exchange pipes embedded in buildings and underground structures to efficiently and stably regulate thermal and humidity environment of building and underground spaces by fully utilizing low-grade energy and heat storage characteristics of the embedded pipe structure. In this review, a comprehensive summary and analysis of the research on embedded pipe heat exchange system are provided, including TABS classification, influencing factors, enhancement strategies, system integration and optimization, application potential, and development trends. The three forms of embedded pipe structures in building enclosures, namely floors, walls, and ceilings, are thoroughly explored. Specifically, to address the demand for environmental regulation in underground spaces, embedding pipes within underground infrastructures is proposed to cater to heating needs in cold region tunnels, cooling requirements in urban tunnels, and deicing/snow melting on road pavements. Various enhancement methods for TABS are suggested to improve operational effectiveness, including utilizing phase change materials, implementing reasonable and effective intermittent operation schemes and control strategies, and integrating with auxiliary air conditioning and dehumidification systems. Future research directions are identified, such as strengthening the prefabrication of embedded pipe thermal activation systems, introducing machine learning algorithms to enhance system intelligence, and combining new technologies to improve system integration as well as integrating the thermo-active system into the fifth-generation district heating and cooling networks. This review work of thermal activation systems with embedded heat transfer pipes will be of some significance in guiding future research and application of embedded pipes heating and cooling of buildings and underground spaces.

Suggested Citation

  • Chen, Zhaoxin & Li, Jiaxuan & Tang, Guoqiang & Zhang, Jiahao & Zhang, Donghai & Gao, Penghui, 2024. "High-efficiency heating and cooling technology with embedded pipes in buildings and underground structures: A review," Renewable and Sustainable Energy Reviews, Elsevier, vol. 192(C).
  • Handle: RePEc:eee:rensus:v:192:y:2024:i:c:s1364032123010675
    DOI: 10.1016/j.rser.2023.114209
    as

    Download full text from publisher

    File URL: http://www.sciencedirect.com/science/article/pii/S1364032123010675
    Download Restriction: Full text for ScienceDirect subscribers only

    File URL: https://libkey.io/10.1016/j.rser.2023.114209?utm_source=ideas
    LibKey link: if access is restricted and if your library uses this service, LibKey will redirect you to where you can use your library subscription to access this item
    ---><---

    As the access to this document is restricted, you may want to search for a different version of it.

    References listed on IDEAS

    as
    1. Ji, Yongming & Wu, Wenze & Qi, Haoyu & Wang, Wenqiang & Hu, Songtao, 2022. "Heat transfer performance analysis of front-end capillary heat exchanger of a subway source heat pump system," Energy, Elsevier, vol. 246(C).
    2. Weidong Lyu & Hefu Pu & Jiannan (Nick) Chen & Zelei Gao, 2020. "Numerical Study on Optimal Scheme of the Geothermally Heated Bridge Deck System," Energies, MDPI, vol. 13(24), pages 1-21, December.
    3. Ibrahim, Mohamad & Wurtz, Etienne & Biwole, Pascal Henry & Achard, Patrick, 2014. "Transferring the south solar energy to the north facade through embedded water pipes," Energy, Elsevier, vol. 78(C), pages 834-845.
    4. Lehmann, B. & Dorer, V. & Gwerder, M. & Renggli, F. & Tödtli, J., 2011. "Thermally activated building systems (TABS): Energy efficiency as a function of control strategy, hydronic circuit topology and (cold) generation system," Applied Energy, Elsevier, vol. 88(1), pages 180-191, January.
    5. Gwerder, M. & Tödtli, J. & Lehmann, B. & Dorer, V. & Güntensperger, W. & Renggli, F., 2009. "Control of thermally activated building systems (TABS) in intermittent operation with pulse width modulation," Applied Energy, Elsevier, vol. 86(9), pages 1606-1616, September.
    6. Yan, Tian & Zhou, Xuan & Xu, Xinhua & Yu, Jinghua & Li, Xianting, 2022. "Parametric analysis on performances of the pipe-encapsulated PCM (PenPCM) wall system coupled with gravity heat-pipe and nocturnal radiant cooler," Renewable Energy, Elsevier, vol. 196(C), pages 161-180.
    7. Wu, Wei & You, Tian & Wang, Baolong & Shi, Wenxing & Li, Xianting, 2014. "Simulation of a combined heating, cooling and domestic hot water system based on ground source absorption heat pump," Applied Energy, Elsevier, vol. 126(C), pages 113-122.
    8. Woong June Chung & Sang Hoon Park & Myoung Souk Yeo & Kwang Woo Kim, 2017. "Control of Thermally Activated Building System Considering Zone Load Characteristics," Sustainability, MDPI, vol. 9(4), pages 1-14, April.
    9. Antonopoulos, K.A. & Tzivanidis, C., 1997. "Numerical solution of unsteady three-dimensional heat transfer during space cooling using ceiling-embedded piping," Energy, Elsevier, vol. 22(1), pages 59-67.
    10. Yu, Cairui & Shen, Dongmei & He, Wei & Hu, Zhongting & Zhang, Sheng & Chu, Wenfeng, 2021. "Parametric analysis of the phase change material wall combining with micro-channel heat pipe and sky radiative cooling technology," Renewable Energy, Elsevier, vol. 178(C), pages 1057-1069.
    11. Zhou, D. & Zhao, C.Y. & Tian, Y., 2012. "Review on thermal energy storage with phase change materials (PCMs) in building applications," Applied Energy, Elsevier, vol. 92(C), pages 593-605.
    12. Barzin, Reza & Chen, John J.J. & Young, Brent R. & Farid, Mohammed M., 2015. "Application of PCM energy storage in combination with night ventilation for space cooling," Applied Energy, Elsevier, vol. 158(C), pages 412-421.
    13. María M. Villar-Ramos & Iván Hernández-Pérez & Karla M. Aguilar-Castro & Ivett Zavala-Guillén & Edgar V. Macias-Melo & Irving Hernández-López & Juan Serrano-Arellano, 2022. "A Review of Thermally Activated Building Systems (TABS) as an Alternative for Improving the Indoor Environment of Buildings," Energies, MDPI, vol. 15(17), pages 1-31, August.
    14. Liu, Jiang & Liu, Yan & Yang, Liu & Liu, Tang & Zhang, Chen & Dong, Hong, 2020. "Climatic and seasonal suitability of phase change materials coupled with night ventilation for office buildings in Western China," Renewable Energy, Elsevier, vol. 147(P1), pages 356-373.
    15. Joanna Sinacka & Edward Szczechowiak, 2021. "An Experimental Study of a Thermally Activated Ceiling Containing Phase Change Material for Different Cooling Load Profiles," Energies, MDPI, vol. 14(21), pages 1-16, November.
    16. Meibodi, Saleh S. & Loveridge, Fleur, 2022. "The future role of energy geostructures in fifth generation district heating and cooling networks," Energy, Elsevier, vol. 240(C).
    17. Ji, Yongming & Wu, Wenze & Hu, Songtao, 2023. "Long-term performance of a front-end capillary heat exchanger for a metro source heat pump system," Applied Energy, Elsevier, vol. 335(C).
    18. Han, Chanjuan & Yu, Xiong (Bill), 2017. "Feasibility of geothermal heat exchanger pile-based bridge deck snow melting system: A simulation based analysis," Renewable Energy, Elsevier, vol. 101(C), pages 214-224.
    19. Zhou, Guobing & He, Jing, 2015. "Thermal performance of a radiant floor heating system with different heat storage materials and heating pipes," Applied Energy, Elsevier, vol. 138(C), pages 648-660.
    Full references (including those not matched with items on IDEAS)

    Most related items

    These are the items that most often cite the same works as this one and are cited by the same works as this one.
    1. Yan, Tian & Zhou, Xuan & Xu, Xinhua & Yu, Jinghua & Li, Xianting, 2022. "Parametric analysis on performances of the pipe-encapsulated PCM (PenPCM) wall system coupled with gravity heat-pipe and nocturnal radiant cooler," Renewable Energy, Elsevier, vol. 196(C), pages 161-180.
    2. Jia, Hongyuan & Pang, Xiufeng & Haves, Philip, 2018. "Experimentally-determined characteristics of radiant systems for office buildings," Applied Energy, Elsevier, vol. 221(C), pages 41-54.
    3. Krzaczek, M. & Florczuk, J. & Tejchman, J., 2019. "Improved energy management technique in pipe-embedded wall heating/cooling system in residential buildings," Applied Energy, Elsevier, vol. 254(C).
    4. Nie, Binjian & She, Xiaohui & Du, Zheng & Xie, Chunping & Li, Yongliang & He, Zhubing & Ding, Yulong, 2019. "System performance and economic assessment of a thermal energy storage based air-conditioning unit for transport applications," Applied Energy, Elsevier, vol. 251(C), pages 1-1.
    5. Hawks, M.A. & Cho, S., 2024. "Review and analysis of current solutions and trends for zero energy building (ZEB) thermal systems," Renewable and Sustainable Energy Reviews, Elsevier, vol. 189(PB).
    6. Heier, Johan & Bales, Chris & Martin, Viktoria, 2015. "Combining thermal energy storage with buildings – a review," Renewable and Sustainable Energy Reviews, Elsevier, vol. 42(C), pages 1305-1325.
    7. Piotr Michalak, 2021. "Selected Aspects of Indoor Climate in a Passive Office Building with a Thermally Activated Building System: A Case Study from Poland," Energies, MDPI, vol. 14(4), pages 1-22, February.
    8. Schmelas, Martin & Feldmann, Thomas & Bollin, Elmar, 2017. "Savings through the use of adaptive predictive control of thermo-active building systems (TABS): A case study," Applied Energy, Elsevier, vol. 199(C), pages 294-309.
    9. Wu, Minqiang & Li, Tingxian & He, Qifan & Du, Ruxue & Wang, Ruzhu, 2022. "Thermally conductive and form-stable phase change composite for building thermal management," Energy, Elsevier, vol. 239(PA).
    10. He, Xianya & Huang, Jingzhi & Liu, Zekun & Lin, Jian & Jing, Rui & Zhao, Yingru, 2023. "Topology optimization of thermally activated building system in high-rise building," Energy, Elsevier, vol. 284(C).
    11. Gohar Gholamibozanjani & Mohammed Farid, 2021. "A Critical Review on the Control Strategies Applied to PCM-Enhanced Buildings," Energies, MDPI, vol. 14(7), pages 1-39, March.
    12. Lim, Jae-Han & Song, Jin-Hee & Song, Seung-Yeong, 2014. "Development of operational guidelines for thermally activated building system according to heating and cooling load characteristics," Applied Energy, Elsevier, vol. 126(C), pages 123-135.
    13. Ma, Peizheng & Wang, Lin-Shu & Guo, Nianhua, 2013. "Modeling of TABS-based thermally manageable buildings in Simulink," Applied Energy, Elsevier, vol. 104(C), pages 791-800.
    14. Ma, Peizheng & Wang, Lin-Shu & Guo, Nianhua, 2014. "Modeling of hydronic radiant cooling of a thermally homeostatic building using a parametric cooling tower," Applied Energy, Elsevier, vol. 127(C), pages 172-181.
    15. Wenqiang Sun & Zuquan Zhao & Yanhui Wang, 2017. "Thermal Analysis of a Thermal Energy Storage Unit to Enhance a Workshop Heating System Driven by Industrial Residual Water," Energies, MDPI, vol. 10(2), pages 1-19, February.
    16. Lydon, G.P. & Hofer, J. & Svetozarevic, B. & Nagy, Z. & Schlueter, A., 2017. "Coupling energy systems with lightweight structures for a net plus energy building," Applied Energy, Elsevier, vol. 189(C), pages 310-326.
    17. Woong June Chung & Sang Hoon Park & Myoung Souk Yeo & Kwang Woo Kim, 2017. "Control of Thermally Activated Building System Considering Zone Load Characteristics," Sustainability, MDPI, vol. 9(4), pages 1-14, April.
    18. Liu, Jiang & Liu, Yan & Yang, Liu & Liu, Tang & Zhang, Chen & Dong, Hong, 2020. "Climatic and seasonal suitability of phase change materials coupled with night ventilation for office buildings in Western China," Renewable Energy, Elsevier, vol. 147(P1), pages 356-373.
    19. Ahmad Hasan & Khaled A. Al-Sallal & Hamza Alnoman & Yasir Rashid & Shaimaa Abdelbaqi, 2016. "Effect of Phase Change Materials (PCMs) Integrated into a Concrete Block on Heat Gain Prevention in a Hot Climate," Sustainability, MDPI, vol. 8(10), pages 1-14, October.
    20. Yu, Tao & Heiselberg, Per & Lei, Bo & Zhang, Chen & Pomianowski, Michal & Jensen, Rasmus, 2016. "Experimental study on the dynamic performance of a novel system combining natural ventilation with diffuse ceiling inlet and TABS," Applied Energy, Elsevier, vol. 169(C), pages 218-229.

    Corrections

    All material on this site has been provided by the respective publishers and authors. You can help correct errors and omissions. When requesting a correction, please mention this item's handle: RePEc:eee:rensus:v:192:y:2024:i:c:s1364032123010675. See general information about how to correct material in RePEc.

    If you have authored this item and are not yet registered with RePEc, we encourage you to do it here. This allows to link your profile to this item. It also allows you to accept potential citations to this item that we are uncertain about.

    If CitEc recognized a bibliographic reference but did not link an item in RePEc to it, you can help with this form .

    If you know of missing items citing this one, you can help us creating those links by adding the relevant references in the same way as above, for each refering item. If you are a registered author of this item, you may also want to check the "citations" tab in your RePEc Author Service profile, as there may be some citations waiting for confirmation.

    For technical questions regarding this item, or to correct its authors, title, abstract, bibliographic or download information, contact: Catherine Liu (email available below). General contact details of provider: http://www.elsevier.com/wps/find/journaldescription.cws_home/600126/description#description .

    Please note that corrections may take a couple of weeks to filter through the various RePEc services.

    IDEAS is a RePEc service. RePEc uses bibliographic data supplied by the respective publishers.