Author
Listed:
- Yang, Yang
- Chen, Sarula
- Li, Shuying
- Xiao, Xiuyi
- Chen, Tianhang
Abstract
Pipe-embedded walls (CnPWs) are structural and energy composite building components that can resist external disturbances by forming stealth thermal shielding layers. To tackle the mismatch between the heat charging rate and heat diffusion rate during energy charging processes, as well as the unsatisfactory robustness of stealth thermal shielding layers, the single-level tree-shaped metal finnd pipe-embedded walls (TfPWs) are proposed. To verify the effectiveness of TfPWs and obtain dynamic performances, a simulation study is conducted on 8 risk variables in 4 pairs through the validated numerical model. Results showed that the improved design was effective in obtaining more robust thermal shielding layers in auxiliary energy supply mode, the effect gained prominence as both the injection temperature and pipe spacing were augmented. In room heat load reduction mode, favorable benefits arise when pipe spacing exceeds 400 mm. The maximum increase rate of total injected energy under different reduction ratios of external insulation layer was 11.83%–31.91 %, while the maximum extra total heat loss was 5.33 %. Secondly, the trunk fins and branch fins played different roles in minimizing the excessive heat accumulation surrounding pipes, and the vertical and horizontal sizes of heat accumulation region mainly increased with the increase in trunk fin size and branch fin size respectively. Meanwhile, the utilization efficiency of fin material was higher when trunk fin size was smaller, and parameter combinations with trunk fin size of 0.2b and branch fin size of 0.4a/0.6a could achieve a better balance between material input and performance increase. Thirdly, the improvement effect of single left branch fin schemes was close to that of double branch fin schemes and significantly better than that of single right branch fin schemes. It was recommended to use single left branch fin schemes with an inclination angle of 60°. Finally, even if the reduction ratio of external insulation layer in different cities increased to 80 %, the inside surface temperature of TfPWs was still greater than room air. Taking CnPWs with standard external insulation layer as references, the TfPWs applied in Harbin, Beijing, and Shanghai could achieve similar or better results even when the reduction ratio of external insulation layer increased to 60 %, while TfPWs applied in Guangzhou could exhibit better performance even when the reduction ratio of external insulation layer increases to 80 %.
Suggested Citation
Yang, Yang & Chen, Sarula & Li, Shuying & Xiao, Xiuyi & Chen, Tianhang, 2024.
"Comprehensive analysis of thermal performance and low-grade energy charging efficiency of pipe-embedded building envelopes enhanced with single-level tree-shaped fin structures,"
Renewable Energy, Elsevier, vol. 237(PB).
Handle:
RePEc:eee:renene:v:237:y:2024:i:pb:s0960148124016847
DOI: 10.1016/j.renene.2024.121616
Download full text from publisher
As the access to this document is restricted, you may want to search for a different version of it.
Corrections
All material on this site has been provided by the respective publishers and authors. You can help correct errors and omissions. When requesting a correction, please mention this item's handle: RePEc:eee:renene:v:237:y:2024:i:pb:s0960148124016847. See general information about how to correct material in RePEc.
If you have authored this item and are not yet registered with RePEc, we encourage you to do it here. This allows to link your profile to this item. It also allows you to accept potential citations to this item that we are uncertain about.
We have no bibliographic references for this item. You can help adding them by using this form .
If you know of missing items citing this one, you can help us creating those links by adding the relevant references in the same way as above, for each refering item. If you are a registered author of this item, you may also want to check the "citations" tab in your RePEc Author Service profile, as there may be some citations waiting for confirmation.
For technical questions regarding this item, or to correct its authors, title, abstract, bibliographic or download information, contact: Catherine Liu (email available below). General contact details of provider: http://www.journals.elsevier.com/renewable-energy .
Please note that corrections may take a couple of weeks to filter through
the various RePEc services.