IDEAS home Printed from https://ideas.repec.org/a/eee/renene/v143y2019icp1865-1876.html
   My bibliography  Save this article

Parametric study on a wall-mounted attached ventilation system for night cooling with different supply air conditions

Author

Listed:
  • Ji, Wenhui
  • Wang, Houhua
  • Du, Tao
  • Zhang, Zili

Abstract

Night ventilation is a sustainable approach to achieve comfortable built environment with relatively low energy consumption in summer. However, the cooling performance of conventional night ventilation in the hot summer climate zone is unsatisfactory due to the insignificant climatic potential. Considering that a large proportion of the heat gains is stored in the building envelope, particularly in the external wall, we propose a novel wall-mounted attached night ventilation (WANV) for night cooling. This novel system is capable of generating a downward air jet that directly flows over the internal surface of the west-external wall to achieve enhanced convective cooling performance on the west wall during the nighttime. The present paper numerically investigates the air flow patterns and temperature field distributions in the test chamber with WANV under different supply air conditions (air velocity and temperature). The shear-stress transport k–omega turbulence model, a blending two-equation eddy-viscosity turbulence model which is suitable to capture airflows with strong streamline curvature and separation, is employed in the numerical study. Comparisons between the experimental data and the simulation results are carried out, and the good agreement suggests that the numerical model is able to predict the air velocity and temperature profiles of the chamber with WANV. The simulation results show that intensive air recirculation and enhanced convection are achieved due to the high turbulent air momentum in the scenario with WANV. A similar tendency of the decay of air velocities in the near-wall region is observed regardless of the supply air velocity. Furthermore, a correlation between the air velocity and the height above the floor is proposed. The cooling performance of WANV is significantly improved by decreasing the supply air temperature. Additionally, the impact of supply air conditions on the cooling performance is quantified using the relative heat releasing effectiveness index, which suggests that the optimal supply air velocity is approximately 4 m/s in hot summer at Chongqing or locations with similar climate conditions.

Suggested Citation

  • Ji, Wenhui & Wang, Houhua & Du, Tao & Zhang, Zili, 2019. "Parametric study on a wall-mounted attached ventilation system for night cooling with different supply air conditions," Renewable Energy, Elsevier, vol. 143(C), pages 1865-1876.
  • Handle: RePEc:eee:renene:v:143:y:2019:i:c:p:1865-1876
    DOI: 10.1016/j.renene.2019.06.022
    as

    Download full text from publisher

    File URL: http://www.sciencedirect.com/science/article/pii/S0960148119308432
    Download Restriction: Full text for ScienceDirect subscribers only

    File URL: https://libkey.io/10.1016/j.renene.2019.06.022?utm_source=ideas
    LibKey link: if access is restricted and if your library uses this service, LibKey will redirect you to where you can use your library subscription to access this item
    ---><---

    As the access to this document is restricted, you may want to search for a different version of it.

    References listed on IDEAS

    as
    1. Artmann, N. & Manz, H. & Heiselberg, P., 2007. "Climatic potential for passive cooling of buildings by night-time ventilation in Europe," Applied Energy, Elsevier, vol. 84(2), pages 187-201, February.
    2. Barzin, Reza & Chen, John J.J. & Young, Brent R. & Farid, Mohammed M., 2015. "Application of PCM energy storage in combination with night ventilation for space cooling," Applied Energy, Elsevier, vol. 158(C), pages 412-421.
    3. Chen, Xiaoming & Zhang, Quan & Zhai, Zhiqiang John & Ma, Xiaowei, 2019. "Potential of ventilation systems with thermal energy storage using PCMs applied to air conditioned buildings," Renewable Energy, Elsevier, vol. 138(C), pages 39-53.
    4. Imessad, K. & Derradji, L. & Messaoudene, N.Ait & Mokhtari, F. & Chenak, A. & Kharchi, R., 2014. "Impact of passive cooling techniques on energy demand for residential buildings in a Mediterranean climate," Renewable Energy, Elsevier, vol. 71(C), pages 589-597.
    5. Saffari, Mohammad & de Gracia, Alvaro & Ushak, Svetlana & Cabeza, Luisa F., 2017. "Passive cooling of buildings with phase change materials using whole-building energy simulation tools: A review," Renewable and Sustainable Energy Reviews, Elsevier, vol. 80(C), pages 1239-1255.
    6. Artmann, N. & Manz, H. & Heiselberg, P., 2008. "Parameter study on performance of building cooling by night-time ventilation," Renewable Energy, Elsevier, vol. 33(12), pages 2589-2598.
    7. Solgi, Ebrahim & Fayaz, Rima & Kari, Behrouz Mohammad, 2016. "Cooling load reduction in office buildings of hot-arid climate, combining phase change materials and night purge ventilation," Renewable Energy, Elsevier, vol. 85(C), pages 725-731.
    Full references (including those not matched with items on IDEAS)

    Citations

    Citations are extracted by the CitEc Project, subscribe to its RSS feed for this item.
    as


    Cited by:

    1. Guo, Rui & Hu, Yue & Heiselberg, Per & Johra, Hicham & Zhang, Chen & Peng, Pei, 2021. "Simulation and optimization of night cooling with diffuse ceiling ventilation and mixing ventilation in a cold climate," Renewable Energy, Elsevier, vol. 179(C), pages 488-501.

    Most related items

    These are the items that most often cite the same works as this one and are cited by the same works as this one.
    1. Liu, Jiang & Liu, Yan & Yang, Liu & Liu, Tang & Zhang, Chen & Dong, Hong, 2020. "Climatic and seasonal suitability of phase change materials coupled with night ventilation for office buildings in Western China," Renewable Energy, Elsevier, vol. 147(P1), pages 356-373.
    2. Yan, Tian & Xu, Xinhua & Gao, Jiajia & Luo, Yongqiang & Yu, Jinghua, 2020. "Performance evaluation of a PCM-embedded wall integrated with a nocturnal sky radiator," Energy, Elsevier, vol. 210(C).
    3. Guo, Rui & Gao, Yafeng & Zhuang, Chaoqun & Heiselberg, Per & Levinson, Ronnen & Zhao, Xia & Shi, Dachuan, 2020. "Optimization of cool roof and night ventilation in office buildings: A case study in Xiamen, China," Renewable Energy, Elsevier, vol. 147(P1), pages 2279-2294.
    4. Hossein Bakhtiari & Jan Akander & Mathias Cehlin & Abolfazl Hayati, 2020. "On the Performance of Night Ventilation in a Historic Office Building in Nordic Climate," Energies, MDPI, vol. 13(16), pages 1-26, August.
    5. Gohar Gholamibozanjani & Mohammed Farid, 2021. "A Critical Review on the Control Strategies Applied to PCM-Enhanced Buildings," Energies, MDPI, vol. 14(7), pages 1-39, March.
    6. Wijesuriya, Sajith & Brandt, Matthew & Tabares-Velasco, Paulo Cesar, 2018. "Parametric analysis of a residential building with phase change material (PCM)-enhanced drywall, precooling, and variable electric rates in a hot and dry climate," Applied Energy, Elsevier, vol. 222(C), pages 497-514.
    7. Alizadeh, M. & Sadrameli, S.M., 2016. "Development of free cooling based ventilation technology for buildings: Thermal energy storage (TES) unit, performance enhancement techniques and design considerations – A review," Renewable and Sustainable Energy Reviews, Elsevier, vol. 58(C), pages 619-645.
    8. Guo, Rui & Hu, Yue & Heiselberg, Per & Johra, Hicham & Zhang, Chen & Peng, Pei, 2021. "Simulation and optimization of night cooling with diffuse ceiling ventilation and mixing ventilation in a cold climate," Renewable Energy, Elsevier, vol. 179(C), pages 488-501.
    9. Yan, Tian & Sun, Zhongwei & Gao, Jiajia & Xu, Xinhua & Yu, Jinghua & Gang, Wenjie, 2020. "Simulation study of a pipe-encapsulated PCM wall system with self-activated heat removal by nocturnal sky radiation," Renewable Energy, Elsevier, vol. 146(C), pages 1451-1464.
    10. Kuczyński, Tadeusz & Staszczuk, Anna, 2023. "Experimental study of the thermal behavior of PCM and heavy building envelope structures during summer in a temperate climate," Energy, Elsevier, vol. 279(C).
    11. Ramponi, Rubina & Angelotti, Adriana & Blocken, Bert, 2014. "Energy saving potential of night ventilation: Sensitivity to pressure coefficients for different European climates," Applied Energy, Elsevier, vol. 123(C), pages 185-195.
    12. Anna Dudzińska & Tomasz Kisilewicz, 2020. "Alternative Ways of Cooling a Passive School Building in Order to Maintain Thermal Comfort in Summer," Energies, MDPI, vol. 14(1), pages 1-20, December.
    13. Qu, Yue & Chen, Jiayu & Liu, Lifang & Xu, Tao & Wu, Huijun & Zhou, Xiaoqing, 2020. "Study on properties of phase change foam concrete block mixed with paraffin / fumed silica composite phase change material," Renewable Energy, Elsevier, vol. 150(C), pages 1127-1135.
    14. Lei Tang & Zhengtao Ai & Chunyan Song & Guoqiang Zhang & Zhengxuan Liu, 2021. "A Strategy to Maximally Utilize Outdoor Air for Indoor Thermal Environment," Energies, MDPI, vol. 14(13), pages 1-13, July.
    15. de Gracia, Alvaro, 2019. "Dynamic building envelope with PCM for cooling purposes – Proof of concept," Applied Energy, Elsevier, vol. 235(C), pages 1245-1253.
    16. Piselli, Cristina & Prabhakar, Mohit & de Gracia, Alvaro & Saffari, Mohammad & Pisello, Anna Laura & Cabeza, Luisa F., 2020. "Optimal control of natural ventilation as passive cooling strategy for improving the energy performance of building envelope with PCM integration," Renewable Energy, Elsevier, vol. 162(C), pages 171-181.
    17. Rathore, Pushpendra Kumar Singh & Shukla, Shailendra Kumar, 2020. "An experimental evaluation of thermal behavior of the building envelope using macroencapsulated PCM for energy savings," Renewable Energy, Elsevier, vol. 149(C), pages 1300-1313.
    18. Montazeri, H. & Montazeri, F., 2018. "CFD simulation of cross-ventilation in buildings using rooftop wind-catchers: Impact of outlet openings," Renewable Energy, Elsevier, vol. 118(C), pages 502-520.
    19. Nie, Binjian & She, Xiaohui & Du, Zheng & Xie, Chunping & Li, Yongliang & He, Zhubing & Ding, Yulong, 2019. "System performance and economic assessment of a thermal energy storage based air-conditioning unit for transport applications," Applied Energy, Elsevier, vol. 251(C), pages 1-1.
    20. Ascione, Fabrizio & De Masi, Rosa Francesca & de Rossi, Filippo & Ruggiero, Silvia & Vanoli, Giuseppe Peter, 2016. "Optimization of building envelope design for nZEBs in Mediterranean climate: Performance analysis of residential case study," Applied Energy, Elsevier, vol. 183(C), pages 938-957.

    Corrections

    All material on this site has been provided by the respective publishers and authors. You can help correct errors and omissions. When requesting a correction, please mention this item's handle: RePEc:eee:renene:v:143:y:2019:i:c:p:1865-1876. See general information about how to correct material in RePEc.

    If you have authored this item and are not yet registered with RePEc, we encourage you to do it here. This allows to link your profile to this item. It also allows you to accept potential citations to this item that we are uncertain about.

    If CitEc recognized a bibliographic reference but did not link an item in RePEc to it, you can help with this form .

    If you know of missing items citing this one, you can help us creating those links by adding the relevant references in the same way as above, for each refering item. If you are a registered author of this item, you may also want to check the "citations" tab in your RePEc Author Service profile, as there may be some citations waiting for confirmation.

    For technical questions regarding this item, or to correct its authors, title, abstract, bibliographic or download information, contact: Catherine Liu (email available below). General contact details of provider: http://www.journals.elsevier.com/renewable-energy .

    Please note that corrections may take a couple of weeks to filter through the various RePEc services.

    IDEAS is a RePEc service. RePEc uses bibliographic data supplied by the respective publishers.