Content
May 2019, Volume 22, Issue 7
- 772-787 Pair-wise vs group-wise registration in statistical shape model construction: representation of physiological and pathological variability of bony surface morphology
by Pietro Cerveri & Antonella Belfatto & Alfonso Manzotti - 788-796 A study on relationship between pulsatile tinnitus and temporal bone pneumatization grade
by Shan Tian & Xingyu Fan & Yawei Wang & Zhaohui Liu & Lizhen Wang
April 2019, Volume 22, Issue 6
- 567-573 Numerical and experimental evaluation of TPMS Gyroid scaffolds for bone tissue engineering
by A. P. G. Castro & R. B. Ruben & S. B. Gonçalves & J. Pinheiro & J. M. Guedes & P. R. Fernandes - 574-584 Rigid-body modeling of knee cartilage and meniscus using experimental pressure-strain curves
by S. Wilson & J. Hausselle & T.M. Guess & R.V. Gonzalez - 585-594 Biomechanical comparison of implant inclinations and load times with the all-on-4 treatment concept: a three-dimensional finite element analysis
by Ting Liu & Zhixiang Mu & Ti Yu & Chao Wang & Yuanding Huang - 595-604 A musculoskeletal shoulder simulation of moment arms and joint reaction forces after medialization of the supraspinatus footprint in rotator cuff repair
by Tim Leschinger & Stefan Birgel & Michael Hackl & Manfred Staat & Lars Peter Müller & Kilian Wegmann - 605-619 Construction of a risk model through the fusion of experimental data and finite element modeling: Application to car crash-induced TBI
by Seyed Saeed Ahmadisoleymani & Samy Missoum - 620-630 Numerical simulation of two-phase non-Newtonian blood flow with fluid-structure interaction in aortic dissection
by Yonghui Qiao & Yujie Zeng & Ying Ding & Jianren Fan & Kun Luo & Ting Zhu - 631-643 The biomechanics of concussion for ice hockey head impact events
by Andrew Post & T. Blaine Hoshizaki & Clara Karton & J. Michio Clark & Lauren Dawson & Janie Cournoyer & Karen Taylor & R. Anna Oeur & Michael D. Gilchrist & Michael D. Cusimano - 644-657 Cascaded statistical shape model based segmentation of the full lower limb in CT
by Emmanuel A. Audenaert & Jan Van Houcke & Diogo F. Almeida & Lena Paelinck & M. Peiffer & Gunther Steenackers & Dirk Vandermeulen - 658-663 Physiological complexity of gait is decreased in individuals with chronic stroke
by Eric L. Dugan & Stephanie A. Combs-Miller - 664-675 Sensitivity of stress and strain calculations to passive material parameters in cardiac mechanical models using unloaded geometries
by S. Kallhovd & J. Sundnes & S. T. Wall - 676-684 Biomechanical and functional effects of shoulder kinesio taping® on cerebral palsy children interacting with virtual objects
by N. García-Hernández & J. Corona-Cortés & L. García-Fuentes & R. Díaz González-Santibañez & V. Parra-Vega
April 2019, Volume 22, Issue 5
- 451-464 Validation of an OpenSim full-body model with detailed lumbar spine for estimating lower lumbar spine loads during symmetric and asymmetric lifting tasks
by Erica Beaucage-Gauvreau & William S. P. Robertson & Scott C. E. Brandon & Robert Fraser & Brian J. C. Freeman & Ryan B. Graham & Dominic Thewlis & Claire F. Jones - 465-474 Effects of membrane reference state on shape memory of a red blood cell
by Zhe Gou & Xiaodong Ruan & Feng Huang & Xin Fu - 475-489 The effect of including increased arterial stiffness in the upper body when modelling Coarctation of the Aorta
by Dilan Pathirana & Barbara Johnston & Peter Johnston - 490-498 Biomechanical comparison of the effects of anterior, posterior and transforaminal lumbar interbody fusion on vibration characteristics of the human lumbar spine
by Wei Fan & Li-Xin Guo - 499-517 An integrated haptic-enabled virtual reality system for orthognathic surgery planning
by Jorge Zaragoza-Siqueiros & Hugo I. Medellin-Castillo & Héctor de la Garza-Camargo & Theodore Lim & James M. Ritchie - 518-532 A methodology for numerically analysing the hepatic artery haemodynamics during B-TACE: a proof of concept
by Jorge Aramburu & Raúl Antón & Alejandro Rivas & Juan Carlos Ramos & Gorka S. Larraona & Bruno Sangro & José Ignacio Bilbao - 533-546 Design and evaluation of the crimping of a hooked self-expandable caval valve stent for the treatment of tricuspid regurgitation
by Gideon Praveen Kumar & Hwa Liang Leo & Fangsen Cui - 547-566 Analysis of the volume of fluid (VOF) method for the simulation of the mucus clearance process with CFD
by Concepción Paz & Eduardo Suárez & Jesús Vence & Adrián Cabarcos
March 2019, Volume 22, Issue 4
- 341-351 Assessment of scapular morphology and bone quality with statistical models
by William S. Burton & Irene Sintini & Jason M. Chavarria & James R. Brownhill & Peter J. Laz - 352-363 Predictions of Birmingham hip resurfacing implant offset - In vitro and numerical models
by A. Ramos & Marco P. Soares dos Santos & M. Mesnard - 364-375 Computational investigations on the hemodynamic performance of a new swirl generator in bifurcated arteries
by B. Prashantha & S. Anish - 376-385 Non-rigid deformation to include subject-specific detail in musculoskeletal models of CP children with proximal femoral deformity and its effect on muscle and contact forces during gait
by Mariska Wesseling & Lode Bosmans & Christophe Van Dijck & Jos Vander Sloten & Roel Wirix-Speetjens & Ilse Jonkers - 386-395 The impact of arm-crank position on the drag of a paralympic hand-cyclist
by Paul Mannion & Yasin Toparlar & Eoghan Clifford & Magdalena Hajdukiewicz & Thomas Andrianne & Bert Blocken - 396-408 A pragmatic approach to understand peripheral artery lumen surface stiffness due to plaque heterogeneity
by Erica E. Neumann & Melissa Young & Ahmet Erdemir - 409-417 Influence of resin cement thickness and temperature variation on mechanical behavior of dental ceramic fragment restoration
by Ana Paula Martini & Fernando Isquierdo de Souza & Rodolfo Bruniera Anchieta & Erika Oliveira de Almeida & Amilcar Chagas Freitas Junior & Eduardo Passos Rocha - 418-425 Assessment of haemophilic arthropathy through balance analysis: a promising tool
by Xavier García-Massó & Yiyao Ye-Lin & Javier Garcia-Casado & Felipe Querol & Luis-Millan Gonzalez - 426-441 An in vivo parameter identification method for arteries: numerical validation for the human abdominal aorta
by Jan-Lucas Gade & Jonas Stålhand & Carl-Johan Thore - 442-449 Development and validation of a finite element model to simulate the opening of a medial opening wedge high tibial osteotomy
by Victor A. Carranza & Jacob Reeves & Alan Getgood & Timothy A. Burkhart
February 2019, Volume 22, Issue 3
- 229-242 Evaluation of helmet and goggle designs by modeling non-penetrating projectile impacts
by Rinat Friedman & Ayelet Haimy & Yoram Epstein & Amit Gefen - 243-250 Effects of medial collateral ligament release, limb correction, and soft tissue laxity on knee joint contact force distribution after medial opening wedge high tibial osteotomy: a computational study
by Tserenchimed Purevsuren & Batbayar Khuyagbaatar & Kyungsoo Kim & Yoon Hyuk Kim - 251-258 Comparison of stress distribution in dental crown with different cusp angles: 3D finite element analysis
by Han-Wool Kim & Byung-Ho Choi & Eun-Jeong Bae & Joong-Yeon Lim - 259-270 Musculoskeletal models with generic and subject-specific geometry estimate different joint biomechanics in dysplastic hips
by Ke Song & Andrew E. Anderson & Jeffrey A. Weiss & Michael D. Harris - 271-279 Polyethylene glenoid component fixation geometry influences stability in total shoulder arthroplasty
by Nikolas K. Knowles & G. Daniel G. Langohr & George S. Athwal & Louis M. Ferreira - 280-287 Evaluation of postoperative dental implant primary stability using 3D finite element analysis
by Dávid Pammer - 288-303 Fluid-structure interaction assessment of blood flow hemodynamics and leaflet stress during mitral regurgitation
by Saeed Adham Esfahani & Kamran Hassani & Daniel M. Espino - 304-312 A voxel-based method for designing a numerical biomechanical model patient-specific with an anatomical functional approach adapted to additive manufacturing
by Augustin Lerebours & Frederic Marin & Salima Bouvier & Christophe Egles & Alain-Charles Masquelet & Alain Rassineux - 313-323 Influence of energy absorbers on Malgaigne fracture mechanism in lumbar-pelvic system under vertical impact load
by K. Arkusz & T. Klekiel & G. Sławiński & R. Będziński - 324-330 Finite element analysis of titanium alloy-graphene based mandible plate
by Prashant Jindal & Frank Worcester & Kartikeya Walia & Anand Gupta & Philip Breedon - 331-339 Voxel-based modeling of airflow in the human nasal cavity
by Shinya Kimura & Takashi Sakamoto & Toshihiro Sera & Hideo Yokota & Kenji Ono & Denis J. Doorly & Robert C. Schroter & Gaku Tanaka
January 2019, Volume 22, Issue 2
- 113-129 Image-based multi-scale mechanical analysis of strain amplification in neurons embedded in collagen gel
by Victor W. L. Chan & William R. Tobin & Sijia Zhang & Beth A. Winkelstein & Victor H. Barocas & Mark S. Shephard & Catalin R. Picu - 130-138 Smart platform for the analysis of cupula deformation caused by otoconia presence within SCCs
by Radun Vulović & Milica Nikolić & Nenad Filipović - 139-148 The effects of the muscular contraction on the abdominal biomechanics: a numerical investigation
by Piero G. Pavan & Silvia Todros & Paola Pachera & Silvia Pianigiani & Arturo N. Natali - 149-158 Routine clinical motion analysis: comparison of a bespoke real-time protocol to current clinical methods
by Lindsay Jane Millar & Lin Meng & Philip John Rowe - 159-168 MusIC method enhancement by a sensitivity study of its performance: Application to a lower limbs musculoskeletal model
by A. Muller & C. Pontonnier & G. Dumont - 169-179 Creating a human head finite element model using a multi-block approach for predicting skull response and brain pressure
by Zhihua Cai & Yun Xia & Zheng Bao & Haojie Mao - 180-205 Numerical assessment of the human body response to a ground-level explosion
by Piotr W. Sielicki & Tomasz Gajewski - 206-216 Patellofemoral cartilage stresses are most sensitive to variations in vastus medialis muscle forces
by Saikat Pal & Thor F. Besier & Garry E. Gold & Michael Fredericson & Scott L. Delp & Gary S. Beaupre - 217-228 A fully coupled framework for in silico investigation of in-stent restenosis
by Shibo Li & Long Lei & Ying Hu & Yanfang Zhang & Shijia Zhao & Jianwei Zhang
January 2019, Volume 22, Issue 1
- 1-2 In memorium Christopher Rae Jacobs
by John Middleton - 3-10 An approach to generate noncontact ACL-injury prone situations on a computer using kinematic data of non-injury situations and Monte Carlo simulation
by R. Eberle & D. Heinrich & A. J. van den Bogert & M. Oberguggenberger & W. Nachbauer - 11-20 Performance criteria for generating predictive optimal control simulations of bicycle pedaling
by Alexis D. Gidley & Anthony P. Marsh & Brian R. Umberger - 21-24 A musculoskeletal model customized for squatting task
by Danilo S. Catelli & Mariska Wesseling & Ilse Jonkers & Mario Lamontagne - 25-37 Calibration of crushable foam plasticity models for synthetic bone material for use in finite element analysis of acetabular cup deformation and primary stability
by Christian Schulze & Danny Vogel & Manuela Sander & Rainer Bader - 38-46 Numerical evaluation of the efficacy of small-caliber colonoscopes in reducing patient pain during a colonoscopy
by Debao Zhou & Xuehuan He - 47-54 Implication of obesity on motion, posture and internal stress of the foot: an experimental and finite element analysis
by B. Kathirgamanathan & P. Silva & J. Fernandez - 55-63 Forward dynamic optimization of handle path and muscle activity for handle based isokinetic wheelchair propulsion: A simulation study
by Nithin Babu Rajendra Kurup & Markus Puchinger & Margit Gföhler - 64-70 Assessing the potential of the qualitative trajectory calculus to detect gait pathologies: a case study of children with developmental coordination disorder
by J. Beernaerts & R. Derie & B. Nguyen & P. Vansteenkiste & B. De Baets & F.J.A. Deconinck & M. Lenoir & D. De Clercq & N. Van de Weghe - 71-83 Investigating sensitivity coefficients characterizing the response of a model of tau protein transport in an axon to model parameters
by Ivan A. Kuznetsov & Andrey V. Kuznetsov - 84-93 A computational approach to investigate optimal cutting speed configurations in rotational needle biopsy cutting soft tissue
by Chi-Lun Lin & Guan-Jhong Lan - 94-99 A proposal for a kinetic summary measure: the Gait Kinetic Index
by Veronica Cimolin & Claudia Condoluci & Pier Francesco Costici & Manuela Galli - 100-111 A new numerical approach to mechanically analyse biological structures
by M. Marques & J. Belinha & L. M. J. S. Dinis & R. M. Natal Jorge
December 2018, Volume 21, Issue 16
- 813-823 A fully coupled fluid-structure interaction model of the secondary lymphatic valve
by John T. Wilson & Lowell T. Edgar & Saurabh Prabhakar & Marc Horner & Raoul van Loon & James E. Moore - 824-833 Hemodynamic investigation of a patient-specific abdominal aortic aneurysm with iliac artery tortuosity
by Yue Qiu & Ding Yuan & Ye Wang & Jun Wen & Tinghui Zheng - 834-844 Validation of a model-based inverse kinematics approach based on wearable inertial sensors
by L. Tagliapietra & L. Modenese & E. Ceseracciu & C. Mazzà & M. Reggiani - 845-851 Numerical study to evaluate the effect of a surface-based sensor on arterial tonometry
by Wookjin Lee & Jaiyoung Ryu & Hangsik Shin & Hong Sun Ryou & Seong Wook Cho
November 2018, Volume 21, Issue 15
- 771-779 Design of a resilient ring for middle ear’s chamber stapes prosthesis
by Emilia Anna Kiryk & Konrad Kamieniecki & Monika Kwacz - 780-783 Novel methods for segment-specific blood flow simulation for the liver
by N. Barléon & R. J. Clarke & H. Ho - 784-794 Development of a three-dimensional body shape model of young children for child restraint design
by Monica L. H. Jones & Sheila M. Ebert & Matthew P. Reed & Kathleen D. Klinich - 795-802 Unloaded shape identification of human cornea by variational shape optimization
by Tomohiro Otani & Masao Tanaka - 803-811 Boundary layer considerations in a multi-layer model for LDL accumulation
by Marcello Iasiello & Kambiz Vafai & Assunta Andreozzi & Nicola Bianco
October 2018, Volume 21, Issue 14
- 731-739 Influence of morphology and material properties on the range of motion of the costovertebral joint – a probabilistic finite element analysis
by Benedikt Schlager & Frank Niemeyer & Christian Liebsch & Fabio Galbusera & Julius Boettinger & Daniel Vogele & Hans-Joachim Wilke - 740-749 Force feasible set prediction with artificial neural network and musculoskeletal model
by Vincent Hernandez & Nasser Rezzoug & Philippe Gorce & Gentiane Venture - 750-759 A two way fully coupled fluid structure simulation of human ureter peristalsis
by Ahmed Tasnub Takaddus & Abhilash J. Chandy - 760-769 MRI based 3D finite element modelling to investigate deep tissue injury
by Willeke A. Traa & Mark C. van Turnhout & Kevin M. Moerman & Jules L. Nelissen & Aart J. Nederveen & Gustav J. Strijkers & Dan L. Bader & Cees W. J. Oomens
October 2018, Volume 21, Issue 13
- 693-702 Preliminary simulation model toward the study of the effects caused by different mandibular advancement devices in OSAS treatment
by Agnese Brunzini & Antonio Gracco & Alida Mazzoli & Marco Mandolini & Steve Manieri & Michele Germani - 703-711 A multiscale investigation of mechanical properties of bio-inspired scaffolds
by Yucong Gu & Mohan Yasodharababu & Arun K. Nair - 712-721 The role of the facet capsular ligament in providing spinal stability
by Emily A. Bermel & Victor H. Barocas & Arin M. Ellingson - 722-729 Anterosuperior protraction of maxillae using the extraoral device, RAMPA; finite element method
by Yasushi Mitani & Bumkyoo Choi & Jaehyuk Choi
September 2018, Volume 21, Issue 12
- 655-662 Finite element analysis of peri-implant bone volume affected by stresses around Morse taper implants: effects of implant positioning to the bone crest
by J. Paulo Macedo & Jorge Pereira & João Faria & Júlio C. M. Souza & J. Luis Alves & José López-López & Bruno Henriques - 663-672 Towards a patient-specific estimation of intra-operative femoral fracture risk
by L. Esposito & P. Bifulco & P. Gargiulo & M.K. Gíslason & M. Cesarelli & L. Iuppariello & H. Jónsson & A. Cutolo & M. Fraldi - 673-683 Uncertainty analysis of material properties and morphology parameters in numerical models regarding the motion of lumbar vertebral segments
by Benedikt Schlager & Frank Niemeyer & Fabio Galbusera & David Volkheimer & René Jonas & Hans-Joachim Wilke - 684-692 A computational study of the EN 1078 impact test for bicycle helmets using a realistic subject-specific finite element head model
by Michael Sandberg & Kwong Ming Tse & Long Bin Tan & Heow Pueh Lee
August 2018, Volume 21, Issue 11
- 617-624 The Biomechanical Effects of Sagittal Split Ramus Osteotomy on Temporomandibular Joint
by Zhan Liu & Jingheng Shu & Yuanli Zhang & Yubo Fan - 625-634 A versatile approach to determine instantaneous co-activation: Development, implementation and comparison to existing measures
by Daniel Viggiani & Jeff M Barrett & Kayla M Fewster & Jack Callaghan - 635-644 Effect of the anisotropic permeability in the frequency dependent properties of the superficial layer of articular cartilage
by D. Gastaldi & M. Taffetani & R. Raiteri & P. Vena - 645-653 Gait variability analysis through phase portrait estimated from the Hilbert transform
by Gustavo Souto de Sá e Souza & Adriano O. Andrade & Marcus Fraga Vieira
July 2018, Volume 21, Issue 10
- 579-584 Patient-specific guides improve hip arthroplasty surgical accuracy
by Adeel Aqil & Sanya Patel & Anatole Wiik & Gareth Jones & Alex Bridle & Justin P. Cobb - 585-592 Estimation of mechanical power and energy cost in elite wheelchair racing by analytical procedures and numerical simulations
by Pedro Forte & Daniel A. Marinho & Jorge E. Morais & Pedro G. Morouço & Tiago M. Barbosa - 593-600 Effectiveness and recovery action of a perturbation balance test – a comparison of single-leg and bipedal stances
by Bálint Petró & Judit T Nagy & Rita M Kiss - 601-615 Analysis of the influence of modelling assumptions on the prediction of the elastic properties of cardiac fibres
by Jacobo Córdova Aquino & Hugo I. Medellín-Castillo
July 2018, Volume 21, Issue 9
- 541-547 Numerical studies of the influence of various geometrical features of a multispiked connecting scaffold prototype on mechanical stresses in peri-implant bone
by Ryszard Uklejewski & Mariusz Winiecki & Adam Patalas & Piotr Rogala - 548-557 A musculoskeletal model of the hand and wrist: model definition and evaluation
by M. Mirakhorlo & N. Van Beek & M. Wesseling & H. Maas & H. E. J. Veeger & I. Jonkers - 558-567 Hemodynamic simulation of intracranial aneurysm growth with virtual silk stent implantation
by Xiao Mo & Qianqian Meng & Xiangyu Ma & Qianqian Zhang & Hongyu Yu & Bin Jing & Han Liu & Qi Yan & Zhizheng Zhuo & Xinjian Yang & Haiyun Li - 568-578 Statistical shape model-based prediction of tibiofemoral cartilage
by Christophe Van Dijck & Roel Wirix-Speetjens & Ilse Jonkers & Jos Vander Sloten
June 2018, Volume 21, Issue 8
- 503-511 Numerical model proposed for a temporomandibular joint prosthesis based on the recovery of the healthy movement
by Henrique Takashi Idogava & Pedro Yoshito Noritomi & Gregory Bregion Daniel - 512-520 Modelling the fracture-healing process as a moving-interface problem using an interface-capturing approach
by M. Pietsch & F. Niemeyer & U. Simon & A. Ignatius & K. Urban - 521-531 A metabolic energy expenditure model with a continuous first derivative and its application to predictive simulations of gait
by Anne D. Koelewijn & Eva Dorschky & Antonie J. van den Bogert - 532-540 Numerical analysis and comparison of flow fields in normal larynx and larynx with unilateral vocal fold paralysis
by Amirhossein Bagheri Sarvestani & Ebrahim Goshtasbi Rad & Kamyar Iravani
May 2018, Volume 21, Issue 7
- 471-478 Foot internal stress distribution during impact in barefoot running as function of the strike pattern
by Enrique Morales-Orcajo & Ricardo Becerro de Bengoa Vallejo & Marta Losa Iglesias & Javier Bayod & Estevam Barbosa de Las Casas - 479-487 Pulsatile flow through a constricted tube: effect of stenosis morphology on hemodynamic parameters
by Panagiotis Kelidis & Efstathios Konstantinidis - 488-497 Does the angulation of the mandibular third molar influence the fragility of the mandibular angle after trauma to the mandibular body? A three-dimensional finite-element study
by Yeliz Kılınç & Zeynep Fatma Zor & Mehmet Kemal Tümer & Erkan Erkmen & Ahmet Kurt - 498-502 Point-cloud registration using adaptive radial basis functions
by Ju Zhang & David Ackland & Justin Fernandez
April 2018, Volume 21, Issue 6
- 437-443 Optimal pressure comfort design for pilot helmets
by Ying Xu & Lian Yun Chen & Hai Bo Zhang & Xin Zhao & Yin Sheng Tian & Li Ding - 444-452 FEBio finite element models of the human lumbar spine
by Sean M. Finley & Darrel S. Brodke & Nicholas T. Spina & Christine A. DeDen & Benjamin J. Ellis - 453-460 A novel computational method to determine subject-specific bite force and occlusal loading during mastication
by Oliver Röhrle & Harnoor Saini & Peter V. S. Lee & David C. Ackland - 461-469 A computational framework to simulate the endolymph flow due to vestibular rehabilitation maneuvers assessed from accelerometer data
by Carla F. Santos & Jorge Belinha & Fernanda Gentil & Marco Parente & Bruno Areias & Renato Natal Jorge
April 2018, Volume 21, Issue 5
- 399-407 Corrugated diaphragm shape design study for hemocompatible pulsatile ventricular assist devices
by C. Loosli & L. Moy & G. Kress & E. Mazza & P. Ermanni - 408-412 Subject specific finite element mesh generation of the pelvis from biplanar x-ray images: application to 120 clinical cases
by Nolwenn Fougeron & Pierre-Yves Rohan & Aurélien Macron & Christophe Travert & Hélène Pillet & Wafa Skalli - 413-426 A two-step procedure for coupling development and usage of a pair of human neck models
by Y. W. Wang & L. Z. Wang & S. Y. Liu & Y. B. Fan - 427-435 Computational biomechanical analysis of postoperative inferior tibiofibular syndesmosis: a modified modeling method
by Haobo Li & Yanxi Chen & Minfei Qiang & Kun Zhang & Yuchen Jiang & Yijie Zhang & Xiaoyang Jia
March 2018, Volume 21, Issue 4
- 297-324 Morphing the feature-based multi-blocks of normative/healthy vertebral geometries to scoliosis vertebral geometries: development of personalized finite element models
by Prasannaah Hadagali & James R. Peters & Sriram Balasubramanian - 325-331 Changes of human movement complexity during maturation: quantitative assessment using multiscale entropy
by M. C. Bisi & R. Stagni - 332-343 Towards patient-specific medializing calcaneal osteotomy for adult flatfoot: a finite element study
by Zhongkui Wang & Masamitsu Kido & Kan Imai & Kazuya Ikoma & Shinichi Hirai - 344-358 Altered lower extremity joint mechanics occur during the star excursion balance test and single leg hop after ACL-reconstruction in a collegiate athlete
by Michael A. Samaan & Stacie I. Ringleb & Sebastian Y. Bawab & Eric K. Greska & Joshua T. Weinhandl - 359-369 Numerical investigation of bone remodelling around immediately loaded dental implants using sika deer (Cervus nippon) antlers as implant bed
by Yun He & Istabrak Hasan & Ludger Keilig & Dominik Fischer & Luisa Ziegler & Marcus Abboud & Gerhard Wahl & Christoph Bourauel - 370-378 An innovative appendage invagination procedure to reduce thrombus formation – a numerical model
by Ori Hazan & Leonid Sternik & Dar Waiss & Michael Eldar & Oshrit Hoffer & Orly Goitein & Rafael Kuperstein & Eli Konen & Zehava Ovadia-Blechman - 379-388 Finite element models of the thigh-buttock complex for assessing static sitting discomfort and pressure sore risk: a literature review
by Léo Savonnet & Xuguang Wang & Sonia Duprey - 389-397 1D simulation of blood flow characteristics in the circle of Willis using THINkS
by George P. Huang & Hongtao Yu & Zifeng Yang & Ryan Schwieterman & Bryan Ludwig
February 2018, Volume 21, Issue 3
- () Corrigendum
by The Editors - 201-207 The effect of Knee-Ankle-Foot orthosis stiffness on the parameters of walking
by Sayed Mohammad Ali Abtahi & Nima Jamshidi & Aram Ghaziasgar - 208-218 Simulating localised cellular inflammation and substrate properties in a strain energy density based bone remodelling algorithm for use in modelling trauma
by Naomi Rosenberg & Anthony M. J. Bull - 219-231 Fluid-structure interaction modeling of aneurysmal arteries under steady-state and pulsatile blood flow: a stability analysis
by Mohammadali Sharzehee & Seyed Saeid Khalafvand & Hai-Chao Han - 232-246 Predicting the cardiac toxicity of drugs using a novel multiscale exposure–response simulator
by Francisco Sahli Costabal & Jiang Yao & Ellen Kuhl - 247-254 Biomechanical analysis of lumbar interbody fusion cages with various lordotic angles: a finite element study
by Zhenjun Zhang & Guy R. Fogel & Zhenhua Liao & Yitao Sun & Weiqiang Liu - 255-263 Patient-specific CT-based 3D passive FSI model for left ventricle in hypertrophic obstructive cardiomyopathy
by Long Deng & Xueying Huang & Chun Yang & Yunhu Song & Dalin Tang - 264-277 Brain tissue analysis of impacts to American football helmets
by Andrew Post & Marshall Kendall & Janie Cournoyer & Clara Karton & R. Anna Oeur & Lauren Dawson & T. Blaine Hoshizaki - 278-286 Does the graft-tunnel friction influence knee joint kinematics and biomechanics after anterior cruciate ligament reconstruction? A finite element study
by Chao Wan & Zhixiu Hao - 287-296 Sensitivity of corneal biomechanical and optical behavior to material parameters using design of experiments method
by Mengchen Xu & Amy L. Lerner & Paul D. Funkenbusch & Ashutosh Richhariya & Geunyoung Yoon
January 2018, Volume 21, Issue 2
- 99-112 The influence of fiber dispersion on the mechanical response of aortic tissues in health and disease: a computational study
by Justyna A. Niestrawska & Daniel Ch. Haspinger & Gerhard A. Holzapfel - 113-128 Sub-millimetre accurate human hand kinematics: from surface to skeleton
by Jumana Ma’touq & Tingli Hu & Sami Haddadin - 129-138 A novel adaptive algorithm for 3D finite element analysis to model extracortical bone growth
by Vee San Cheong & Gordon W. Blunn & Melanie J. Coathup & Paul Fromme - 139-148 Model reduction methodology for computational simulations of endovascular repair
by V. A. Acosta Santamaría & G. Daniel & D. Perrin & J. N. Albertini & E. Rosset & S. Avril - 149-160 The MusIC method: a fast and quasi-optimal solution to the muscle forces estimation problem
by A. Muller & C. Pontonnier & G. Dumont - 161-168 The use of functionally graded dental crowns to improve biocompatibility: a finite element analysis
by Mojtaba Mahmoudi & Ali Reza Saidi & Maryam Alsadat Hashemipour & Parviz Amini - 169-176 Assessment of cortical bone fracture resistance curves by fusing artificial neural networks and linear regression
by Arso M. Vukicevic & Gordana R. Jovicic & Milos N. Jovicic & Vladimir L. Milicevic & Nenad D. Filipovic - 177-185 A three-dimensional topology optimization model for tooth-root morphology
by K.-F. Seitz & J. Grabe & T. Köhne - 186-193 Error reduction in the finite helical axis for knee kinematics
by Emily L. Bishop & Jessica C. Küpper & Ingrid R. Fjeld & Gregor Kuntze & Janet L. Ronsky - 194-200 The potential role of variations in juvenile hip geometry on the development of Legg-Calvé-Perthes disease: a biomechanical investigation
by Manuel da Silva Pinheiro & Catherine Dobson & Nicholas M. Clarke & Michael Fagan
January 2018, Volume 21, Issue 1
- 1-12 Numerical identification of the rupture locations in patient-specific abdominal aortic aneurysmsusing hemodynamic parameters
by Yue Qiu & Ding Yuan & Jun Wen & Yubo Fan & Tinghui Zheng - 13-21 Contribution to FE modeling for intraoperative pedicle screw strength prediction
by Maxim Van den Abbeele & Jean-Marc Valiadis & Lucas V. P. C. Lima & Pascal Khalifé & Philippe Rouch & Wafa Skalli - 22-32 A two-dimensional numerical study of peristaltic contractions in obstructed ureter flows
by Z. Najafi & B. F. Schwartz & A. J. Chandy & A. M. Mahajan - 33-46 A finite element model of myocardial infarction using a composite material approach
by Seyyed M. H. Haddad & Abbas Samani - 47-54 Path planning for minimally-invasive knee surgery using a hybrid optimization procedure
by Adam Ciszkiewicz & Grzegorz Milewski - 55-64 New method for estimating arterial pulse wave velocity at single site
by Khaled Ben Abdessalem & Patrice Flaud & Samir Zobaidi - 65-74 Optimization of three-dimensional modeling for geometric precision and efficiency for healthy and diseased aortas
by Christopher P. Cheng & Yufei D. Zhu & Ga-Young Suh - 75-82 Cross-bridge mechanism of residual force enhancement after stretching in a skeletal muscle
by Youjiro Tamura - 83-90 Using 3D finite element models verified the importance of callus material and microstructure in biomechanics restoration during bone defect repair
by Chentian Li & Rongwei Tan & Yuanjun Guo & Songjian Li - 91-97 Influence of transmucosal height in abutments of single and multiple implant-supported prostheses: a non-linear three-dimensional finite element analysis
by Eduardo Borie & Eduardo Leal & Iara Augusta Orsi & Carlos Salamanca & Fernando José Dias & Benjamin Weber
October 2017, Volume 20, Issue S1
- 1-2 Intervertebral efforts quantification using a multibody dynamics approach: application to scoliosis
by G. Abedrabbo & O. Cartiaux & P. Mahaudens & C. Detrembleur & M. Mousny & P. Fisette - 1-2 Intervertebral efforts quantification using a multibody dynamics approach: application to scoliosis
by G. Abedrabbo & O. Cartiaux & P. Mahaudens & C. Detrembleur & M. Mousny & P. Fisette - 3-4 Design and implementation of an electronic goniometer for gait analysis
by C. Adel & Y. Benabid & M. A. Louar - 3-4 Design and implementation of an electronic goniometer for gait analysis
by C. Adel & Y. Benabid & M. A. Louar - 5-6 Reducing the number of cameras and increasing the calibrated volume for motion capture
by A. Aissaoui & P. Pudlo & I. Aloui & A. Ouafi & A. Taleb-Ahmed - 5-6 Reducing the number of cameras and increasing the calibrated volume for motion capture
by A. Aissaoui & P. Pudlo & I. Aloui & A. Ouafi & A. Taleb-Ahmed - 7-8 Assessment of power losses due to ground contact forces during usual manual wheelchair movements
by J. Bascou & C. Fallot & H. Pillet & S. Hybois & F. Lavaste & C. Sauret - 7-8 Assessment of power losses due to ground contact forces during usual manual wheelchair movements
by J. Bascou & C. Fallot & H. Pillet & S. Hybois & F. Lavaste & C. Sauret - 9-10 Analysis of human-exoskeleton interactions: an elbow flexion/extension case study
by S. Bastide & N. Vignais & F. Geffard & B. Berret - 9-10 Analysis of human-exoskeleton interactions: an elbow flexion/extension case study
by S. Bastide & N. Vignais & F. Geffard & B. Berret - 11-12 Analysis of the effect of helmet shape and head position on performance during time-trial cycling
by F. Beaumont & R. Taiar & G. Polidori & H. Zaidi & F. Grappe - 11-12 Analysis of the effect of helmet shape and head position on performance during time-trial cycling
by F. Beaumont & R. Taiar & G. Polidori & H. Zaidi & F. Grappe - 13-14 Finite element analysis of mechanical behavior of stabilization techniques for tibial plateau fractures
by D. Belaid & A. Germaneau & A. Bouchoucha & F. Brémand & C. Brèque & P. Rigoard & T. Vendeuvre - 13-14 Finite element analysis of mechanical behavior of stabilization techniques for tibial plateau fractures
by D. Belaid & A. Germaneau & A. Bouchoucha & F. Brémand & C. Brèque & P. Rigoard & T. Vendeuvre - 15-16 Toward low cost system for real time monitoring of spine movement
by K. Ben Mansour & F. Crison & C. Trabelsi & C. Palazzo & A. Roren & E. Klinger - 15-16 Toward low cost system for real time monitoring of spine movement
by K. Ben Mansour & F. Crison & C. Trabelsi & C. Palazzo & A. Roren & E. Klinger - 17-18 Effects of foot progression angle on knee biomechanics during gait modification
by S. Bennour & B. Ulrich & T. Legrand & B. Jolles & J. Favre - 17-18 Effects of foot progression angle on knee biomechanics during gait modification
by S. Bennour & B. Ulrich & T. Legrand & B. Jolles & J. Favre - 19-20 Effects of shoe drop on running mechanics in women
by T. Besson & C. Morio & J. Rossi - 19-20 Effects of shoe drop on running mechanics in women
by T. Besson & C. Morio & J. Rossi - 21-22 Lung tissue modelling under non-penetrating impact: a comparative investigation on numerical injury criteria
by M. Bodo & S. Roth - 21-22 Lung tissue modelling under non-penetrating impact: a comparative investigation on numerical injury criteria
by M. Bodo & S. Roth - 23-24 Acute effect of biomechanical foot orthotics on gross efficiency in cyclists affected by an anatomic asymmetry in time trial position
by A. Bouillod & M. Retali & G. Soto-Romero & E. Brunet & M. Frémeaux & J. Cassirame & J. Maillot & F. Grappe - 23-24 Acute effect of biomechanical foot orthotics on gross efficiency in cyclists affected by an anatomic asymmetry in time trial position
by A. Bouillod & M. Retali & G. Soto-Romero & E. Brunet & M. Frémeaux & J. Cassirame & J. Maillot & F. Grappe - 25-26 Overcorrected glenoid implants to prevent recurrent glenohumeral subluxation after total shoulder arthroplasty: a patient-specific finite element analysis
by Y. Boulanaache & S. Bergamin & F. Becce & A. Farron & A. Terrier - 25-26 Overcorrected glenoid implants to prevent recurrent glenohumeral subluxation after total shoulder arthroplasty: a patient-specific finite element analysis
by Y. Boulanaache & S. Bergamin & F. Becce & A. Farron & A. Terrier - 27-28 Design process of custom-fitted interbody cage for lumbar spinal fusion
by M. Bounabi & Y. Benabid & A.C. Messellek & A. Azzouz & S. Abid - 27-28 Design process of custom-fitted interbody cage for lumbar spinal fusion
by M. Bounabi & Y. Benabid & A.C. Messellek & A. Azzouz & S. Abid - 29-30 Contribution of vertical and horizontal components of ground reaction forces on global motor moment during a golf swing: a preliminary study
by M. Bourgain & C. Sauret & O. Rouillon & P. Thoreux & P. Rouch - 29-30 Contribution of vertical and horizontal components of ground reaction forces on global motor moment during a golf swing: a preliminary study
by M. Bourgain & C. Sauret & O. Rouillon & P. Thoreux & P. Rouch - 31-32 Methodology for ballistic blunt trauma assessment
by A. Bracq & C. Maréchal & R. Delille & B. Bourel & S. Roth & O. Mauzac - 31-32 Methodology for ballistic blunt trauma assessment
by A. Bracq & C. Maréchal & R. Delille & B. Bourel & S. Roth & O. Mauzac - 33-34 Relationship between cerebral aneurysm wall stiffness and rupture risk
by H. Brunel & D. Ambard & H. Dufour & P. H. Roche & V. Costalat & F. Jourdan - 33-34 Relationship between cerebral aneurysm wall stiffness and rupture risk
by H. Brunel & D. Ambard & H. Dufour & P. H. Roche & V. Costalat & F. Jourdan - 35-36 Finite element model of a below-knee amputation: a feasibility study
by D. Campion & N. Dakhil & M. Llari & M. Evin & F. Mo & L. Thefenne & M. Behr - 35-36 Finite element model of a below-knee amputation: a feasibility study
by D. Campion & N. Dakhil & M. Llari & M. Evin & F. Mo & L. Thefenne & M. Behr - 37-38 Mechanical performance determinants in women’s vs men’s pole-vault
by J. Cassirame & H. Sanchez & S. Homo & J. Frère - 37-38 Mechanical performance determinants in women’s vs men’s pole-vault
by J. Cassirame & H. Sanchez & S. Homo & J. Frère - 39-40 Prediction of intervertebral disc mechanical response to axial load using isotropic and fiber reinforced FE models
by M. A. Chetoui & O. Boiron & A. Dogui & V. Deplano - 39-40 Prediction of intervertebral disc mechanical response to axial load using isotropic and fiber reinforced FE models
by M. A. Chetoui & O. Boiron & A. Dogui & V. Deplano - 41-42 Breathing through a spirometer perturbs balance
by L. Clavel & V. Attali & O. Jacq & MC. Nierat & T. Similowski & P. Rouch & B. Sandoz - 41-42 Breathing through a spirometer perturbs balance
by L. Clavel & V. Attali & O. Jacq & MC. Nierat & T. Similowski & P. Rouch & B. Sandoz - 43-44 Muscle Contraction and Pressure-Volume Loops in the Left-Heart
by J. I. Colorado-Cervantes & Valerio Varano & Luciano Teresi & Vittorio Sansalone - 43-44 Muscle Contraction and Pressure-Volume Loops in the Left-Heart
by J. I. Colorado-Cervantes & Valerio Varano & Luciano Teresi & Vittorio Sansalone - 45-46 Experimental Bench for Hemodynamic Study of Coronary Artery with Serial Stenoses: Fractional Flow Reserve Assessment
by R. Coppel & AL. Gomez & G. Finet & M. Mauro & RI. Pettigrew & J. Ohayon & M. Lagache - 45-46 Experimental Bench for Hemodynamic Study of Coronary Artery with Serial Stenoses: Fractional Flow Reserve Assessment
by R. Coppel & AL. Gomez & G. Finet & M. Mauro & RI. Pettigrew & J. Ohayon & M. Lagache