IDEAS home Printed from https://ideas.repec.org/a/eee/appene/v87y2010i5p1522-1528.html
   My bibliography  Save this article

Performance of a split-type air conditioner matched with coiled adiabatic capillary tubes using HCFC22 and HC290

Author

Listed:
  • Zhou, Guobing
  • Zhang, Yufeng

Abstract

This paper experimentally investigated the system performance of a split-type air conditioner matching with different coiled adiabatic capillary tubes for HCFC22 and HC290. Experiments were carried out in a room-type calorimeter. The results have shown that (1) similar cooling effects can be achieved by matching various capillary tubes of different inner diameters; (2) parallel capillary tubes presented better system performance and flow stability with weaker inlet pressure fluctuations than the single capillary tube; (3) with the coil diameter of the capillary tube increasing from 40Â mm to 120Â mm, the mass flow rate tended to increase slightly. But the cooling capacity, input power and energy efficiency ratio (EER) did not show evident tendency of change; (4) the refrigerant charge and mass flow rate for HC290 were only 44% and 47% of that for HCFC22, respectively, due to the much lower density. And HC290 had 4.7-6.7% lower cooling capacity and 12.1-12.3% lower input power with respect to HCFC22. However, the EER of HC290 can be 8.5% higher than that of HCFC22, which exhibits the advantage of using HC290. In addition, the experimental uncertainties were analyzed and some application concerns of HC290 were discussed.

Suggested Citation

  • Zhou, Guobing & Zhang, Yufeng, 2010. "Performance of a split-type air conditioner matched with coiled adiabatic capillary tubes using HCFC22 and HC290," Applied Energy, Elsevier, vol. 87(5), pages 1522-1528, May.
  • Handle: RePEc:eee:appene:v:87:y:2010:i:5:p:1522-1528
    as

    Download full text from publisher

    File URL: http://www.sciencedirect.com/science/article/pii/S0306-2619(09)00433-4
    Download Restriction: Full text for ScienceDirect subscribers only
    ---><---

    As the access to this document is restricted, you may want to search for a different version of it.

    References listed on IDEAS

    as
    1. Park, Ki-Jung & Jung, Dongsoo, 2009. "Performance of heat pumps charged with R170/R290 mixture," Applied Energy, Elsevier, vol. 86(12), pages 2598-2603, December.
    2. Park, Ki-Jung & Seo, Taebeom & Jung, Dongsoo, 2007. "Performance of alternative refrigerants for residential air-conditioning applications," Applied Energy, Elsevier, vol. 84(10), pages 985-991, October.
    3. Ge, Yunting & Cropper, Roy, 2004. "Air-cooled condensers in retail systems using R22 and R404A refrigerants," Applied Energy, Elsevier, vol. 78(1), pages 95-110, May.
    4. Park, Ki-Jung & Shim, Yun-Bo & Jung, Dongsoo, 2008. "Performance of R433A for replacing HCFC22 used in residential air-conditioners and heat pumps," Applied Energy, Elsevier, vol. 85(9), pages 896-900, September.
    Full references (including those not matched with items on IDEAS)

    Citations

    Citations are extracted by the CitEc Project, subscribe to its RSS feed for this item.
    as


    Cited by:

    1. Kasni Sumeru & Triaji Pangripto Pramudantoro & Andriyanto Setyawan & Rizki Muliawan & Toto Tohir & Mohamad Firdaus bin Sukri, 2022. "Effect of Compressor-Discharge-Cooler Heat-Exchanger Length Using Condensate Water on the Performance of a Split-Type Air Conditioner Using R32 as Working Fluid," Energies, MDPI, vol. 15(21), pages 1-16, October.
    2. Ziya Sogut, M., 2012. "Exergetic and environmental assessment of room air conditioners in Turkish market," Energy, Elsevier, vol. 46(1), pages 32-41.
    3. Yang, Zhao & Wu, Xi, 2013. "Retrofits and options for the alternatives to HCFC-22," Energy, Elsevier, vol. 59(C), pages 1-21.
    4. Yang, YauBin & Wu, Min-Der & Chang, Yu-Choung, 2014. "Temperature control of the four-zone split inverter air conditioners using LMI expression based on LQR for mixed H2/H∞," Applied Energy, Elsevier, vol. 113(C), pages 912-923.
    5. Bansal, Pradeep, 2015. "High efficiency novel window air conditioner," Applied Energy, Elsevier, vol. 156(C), pages 311-320.

    Most related items

    These are the items that most often cite the same works as this one and are cited by the same works as this one.
    1. Comakli, K. & Simsek, F. & Comakli, O. & Sahin, B., 2009. "Determination of optimum working conditions R22 and R404A refrigerant mixtures in heat-pumps using Taguchi method," Applied Energy, Elsevier, vol. 86(11), pages 2451-2458, November.
    2. Zhang, Shengjun & Wang, Huaixin & Guo, Tao, 2010. "Experimental investigation of moderately high temperature water source heat pump with non-azeotropic refrigerant mixtures," Applied Energy, Elsevier, vol. 87(5), pages 1554-1561, May.
    3. Guo, Hao & Gong, Maoqiong & Qin, Xiaoyu, 2019. "Performance analysis of a modified subcritical zeotropic mixture recuperative high-temperature heat pump," Applied Energy, Elsevier, vol. 237(C), pages 338-352.
    4. Yang, Zhao & Wu, Xi, 2013. "Retrofits and options for the alternatives to HCFC-22," Energy, Elsevier, vol. 59(C), pages 1-21.
    5. Harby, K., 2017. "Hydrocarbons and their mixtures as alternatives to environmental unfriendly halogenated refrigerants: An updated overview," Renewable and Sustainable Energy Reviews, Elsevier, vol. 73(C), pages 1247-1264.
    6. Zhang, Jing & Zhang, Hong-Hu & He, Ya-Ling & Tao, Wen-Quan, 2016. "A comprehensive review on advances and applications of industrial heat pumps based on the practices in China," Applied Energy, Elsevier, vol. 178(C), pages 800-825.
    7. Kutub Uddin & Bidyut Baran Saha, 2022. "An Overview of Environment-Friendly Refrigerants for Domestic Air Conditioning Applications," Energies, MDPI, vol. 15(21), pages 1-24, October.
    8. Wang, Q. & Li, D.H. & Wang, J.P. & Sun, T.F. & Han, X.H. & Chen, G.M., 2013. "Numerical investigations on the performance of a single-stage auto-cascade refrigerator operating with two vapor–liquid separators and environmentally benign binary refrigerants," Applied Energy, Elsevier, vol. 112(C), pages 949-955.
    9. Chua, K.J. & Chou, S.K. & Yang, W.M., 2010. "Advances in heat pump systems: A review," Applied Energy, Elsevier, vol. 87(12), pages 3611-3624, December.
    10. Hao, Xinyue & Wang, Lin & Wang, Zhanwei & Tan, Yingying & Yan, Xiaona, 2018. "Hybrid auto-cascade refrigeration system coupled with a heat-driven ejector cooling cycle," Energy, Elsevier, vol. 161(C), pages 988-998.
    11. Eleonora Ponticorvo & Mariagrazia Iuliano & Claudia Cirillo & Angelo Maiorino & Ciro Aprea & Maria Sarno, 2022. "Fouling Behavior and Dispersion Stability of Nanoparticle-Based Refrigeration Fluid," Energies, MDPI, vol. 15(9), pages 1-21, April.
    12. Chen, Lei & Yang, Lijun & Du, Xiaoze & Yang, Yongping, 2016. "A novel layout of air-cooled condensers to improve thermo-flow performances," Applied Energy, Elsevier, vol. 165(C), pages 244-259.
    13. Yu, Binbin & Yang, Jingye & Wang, Dandong & Shi, Junye & Guo, Zhikai & Chen, Jiangping, 2019. "Experimental energetic analysis of CO2/R41 blends in automobile air-conditioning and heat pump systems," Applied Energy, Elsevier, vol. 239(C), pages 1142-1153.
    14. David A. Morgott, 2018. "The Human Exposure Potential from Propylene Releases to the Environment," IJERPH, MDPI, vol. 15(1), pages 1-30, January.
    15. Jun Fan & Haotian Dong & Xiangyang Xu & De Teng & Bo Yan & Yuanbin Zhao, 2019. "Numerical Investigation on the Influence of Mechanical Draft Wet-Cooling Towers on the Cooling Performance of Air-Cooled Condenser with Complex Building Environment," Energies, MDPI, vol. 12(23), pages 1-16, November.
    16. Yang, L.J. & Wang, M.H. & Du, X.Z. & Yang, Y.P., 2012. "Trapezoidal array of air-cooled condensers to restrain the adverse impacts of ambient winds in a power plant," Applied Energy, Elsevier, vol. 99(C), pages 402-413.
    17. Megdouli, K. & Ejemni, N. & Nahdi, E. & Mhimid, A. & Kairouani, L., 2017. "Thermodynamic analysis of a novel ejector expansion transcritical CO2/N2O cascade refrigeration (NEETCR) system for cooling applications at low temperatures," Energy, Elsevier, vol. 128(C), pages 586-600.
    18. Chae, Kyu-Jung & Ren, Xianghao, 2016. "Flexible and stable heat energy recovery from municipal wastewater treatment plants using a fixed-inverter hybrid heat pump system," Applied Energy, Elsevier, vol. 179(C), pages 565-574.
    19. Vannoni, Alberto & Sorce, Alessandro & Traverso, Alberto & Fausto Massardo, Aristide, 2023. "Large size heat pumps advanced cost functions introducing the impact of design COP on capital costs," Energy, Elsevier, vol. 284(C).
    20. Park, Ki-Jung & Shim, Yun-Bo & Jung, Dongsoo, 2008. "Performance of R433A for replacing HCFC22 used in residential air-conditioners and heat pumps," Applied Energy, Elsevier, vol. 85(9), pages 896-900, September.

    Corrections

    All material on this site has been provided by the respective publishers and authors. You can help correct errors and omissions. When requesting a correction, please mention this item's handle: RePEc:eee:appene:v:87:y:2010:i:5:p:1522-1528. See general information about how to correct material in RePEc.

    If you have authored this item and are not yet registered with RePEc, we encourage you to do it here. This allows to link your profile to this item. It also allows you to accept potential citations to this item that we are uncertain about.

    If CitEc recognized a bibliographic reference but did not link an item in RePEc to it, you can help with this form .

    If you know of missing items citing this one, you can help us creating those links by adding the relevant references in the same way as above, for each refering item. If you are a registered author of this item, you may also want to check the "citations" tab in your RePEc Author Service profile, as there may be some citations waiting for confirmation.

    For technical questions regarding this item, or to correct its authors, title, abstract, bibliographic or download information, contact: Catherine Liu (email available below). General contact details of provider: http://www.elsevier.com/wps/find/journaldescription.cws_home/405891/description#description .

    Please note that corrections may take a couple of weeks to filter through the various RePEc services.

    IDEAS is a RePEc service. RePEc uses bibliographic data supplied by the respective publishers.