Trapezoidal array of air-cooled condensers to restrain the adverse impacts of ambient winds in a power plant
Author
Abstract
Suggested Citation
DOI: 10.1016/j.apenergy.2012.06.006
Download full text from publisher
As the access to this document is restricted, you may want to search for a different version of it.
References listed on IDEAS
- Yu, F.W. & Chan, K.T., 2006. "Improved condenser design and condenser-fan operation for air-cooled chillers," Applied Energy, Elsevier, vol. 83(6), pages 628-648, June.
- Barigozzi, G. & Perdichizzi, A. & Ravelli, S., 2011. "Wet and dry cooling systems optimization applied to a modern waste-to-energy cogeneration heat and power plant," Applied Energy, Elsevier, vol. 88(4), pages 1366-1376, April.
- Yu, F.W. & Chan, K.T., 2007. "Modelling of a condenser-fan control for an air-cooled centrifugal chiller," Applied Energy, Elsevier, vol. 84(11), pages 1117-1135, November.
- Ge, Yunting & Cropper, Roy, 2004. "Air-cooled condensers in retail systems using R22 and R404A refrigerants," Applied Energy, Elsevier, vol. 78(1), pages 95-110, May.
- Yu, F.W. & Chan, K.T., 2010. "Simulation and electricity savings estimation of air-cooled centrifugal chiller system with mist pre-cooling," Applied Energy, Elsevier, vol. 87(4), pages 1198-1206, April.
Citations
Citations are extracted by the CitEc Project, subscribe to its RSS feed for this item.
Cited by:
- Wenhui Huang & Lei Chen & Weijia Wang & Lijun Yang & Xiaoze Du, 2020. "Cooling Performance Optimization of Direct Dry Cooling System Based on Partition Adjustment of Axial Flow Fans," Energies, MDPI, vol. 13(12), pages 1-22, June.
- Wenhui Huang & Lei Chen & Lijun Yang & Xiaoze Du, 2021. "Energy-Saving Strategies of Axial Flow Fans for Direct Dry Cooling System," Energies, MDPI, vol. 14(11), pages 1-25, May.
- Hu, Hemin & Li, Zhigang & Jiang, Yuyan & Du, Xiaoze, 2018. "Thermodynamic characteristics of thermal power plant with hybrid (dry/wet) cooling system," Energy, Elsevier, vol. 147(C), pages 729-741.
- Haotian Dong & Dawei Wan & Minghua Liu & Tiefeng Chen & Shasha Gao & Yuanbin Zhao, 2020. "Evaluation of the Hot Air Recirculation Effect and Relevant Empirical Formulae Applicability for Mechanical Draft Wet Cooling Towers," Energies, MDPI, vol. 13(13), pages 1-20, June.
- Tarun Kumar Aseri & Chandan Sharma & Tara C. Kandpal, 2022. "Condenser cooling technologies for concentrating solar power plants: a review," Environment, Development and Sustainability: A Multidisciplinary Approach to the Theory and Practice of Sustainable Development, Springer, vol. 24(4), pages 4511-4565, April.
- Chen, Lei & Yang, Lijun & Du, Xiaoze & Yang, Yongping, 2016. "A novel layout of air-cooled condensers to improve thermo-flow performances," Applied Energy, Elsevier, vol. 165(C), pages 244-259.
- Yang, Lijun & Zhao, Xiaoli & Du, Xiaoze & Yang, Yongping, 2014. "Heat load capability matching principle and its applications to anti-freezing of air-cooled condenser," Applied Energy, Elsevier, vol. 127(C), pages 34-43.
- Zhang, Yi & Liu, Jinfeng & Yang, Tingting & Liu, Jianbang & Shen, Jiong & Fang, Fang, 2021. "Dynamic modeling and control of direct air-cooling condenser pressure considering couplings with adjacent systems," Energy, Elsevier, vol. 236(C).
- Butler, C. & Grimes, R., 2014. "The effect of wind on the optimal design and performance of a modular air-cooled condenser for a concentrated solar power plant," Energy, Elsevier, vol. 68(C), pages 886-895.
- Luceño, José A. & Martín, Mariano, 2018. "Two-step optimization procedure for the conceptual design of A-frame systems for solar power plants," Energy, Elsevier, vol. 165(PB), pages 483-500.
- Li, Xiaoen & Wang, Ningling & Wang, Ligang & Yang, Yongping & Maréchal, François, 2018. "Identification of optimal operating strategy of direct air-cooling condenser for Rankine cycle based power plants," Applied Energy, Elsevier, vol. 209(C), pages 153-166.
Most related items
These are the items that most often cite the same works as this one and are cited by the same works as this one.- Chen, Lei & Yang, Lijun & Du, Xiaoze & Yang, Yongping, 2016. "A novel layout of air-cooled condensers to improve thermo-flow performances," Applied Energy, Elsevier, vol. 165(C), pages 244-259.
- Catrini, Pietro & La Villetta, M. & Kumar, Dhirendran Munith & Morale, Massimo & Piacentino, Antonio, 2024. "Analysis of the operation of air-cooled chillers with variable-speed fans for advanced energy-saving-oriented control strategies," Applied Energy, Elsevier, vol. 367(C).
- Jun Fan & Haotian Dong & Xiangyang Xu & De Teng & Bo Yan & Yuanbin Zhao, 2019. "Numerical Investigation on the Influence of Mechanical Draft Wet-Cooling Towers on the Cooling Performance of Air-Cooled Condenser with Complex Building Environment," Energies, MDPI, vol. 12(23), pages 1-16, November.
- Hu, Hemin & Li, Zhigang & Jiang, Yuyan & Du, Xiaoze, 2018. "Thermodynamic characteristics of thermal power plant with hybrid (dry/wet) cooling system," Energy, Elsevier, vol. 147(C), pages 729-741.
- Li, Xiaoxiao & Duniam, Sam & Gurgenci, Hal & Guan, Zhiqiang & Veeraragavan, Anand, 2017. "Full scale experimental study of a small natural draft dry cooling tower for concentrating solar thermal power plant," Applied Energy, Elsevier, vol. 193(C), pages 15-27.
- Luceño, José A. & Martín, Mariano, 2018. "Two-step optimization procedure for the conceptual design of A-frame systems for solar power plants," Energy, Elsevier, vol. 165(PB), pages 483-500.
- Kong, Yanqiang & Wang, Weijia & Yang, Lijun & Du, Xiaoze, 2020. "Energy efficient strategies for anti-freezing of air-cooled heat exchanger," Applied Energy, Elsevier, vol. 261(C).
- Piacentino, Antonio & Cardona, Ennio, 2010. "Scope Oriented Thermoeconomic analysis of energy systems. Part II: Formation Structure of Optimality for robust design," Applied Energy, Elsevier, vol. 87(3), pages 957-970, March.
- de la Calle, Alberto & Bayon, Alicia & Soo Too, Yen Chean, 2018. "Impact of ambient temperature on supercritical CO2 recompression Brayton cycle in arid locations: Finding the optimal design conditions," Energy, Elsevier, vol. 153(C), pages 1016-1027.
- Namuli, R. & Pillay, P. & Jaumard, B. & Laflamme, C.B., 2013. "Threshold herd size for commercial viability of biomass waste to energy conversion systems on rural farms," Applied Energy, Elsevier, vol. 108(C), pages 308-322.
- Serrano, Juan Miguel & Navarro, Pedro & Ruiz, Javier & Palenzuela, Patricia & Lucas, Manuel & Roca, Lidia, 2024. "Wet cooling tower performance prediction in CSP plants: A comparison between artificial neural networks and Poppe’s model," Energy, Elsevier, vol. 303(C).
- Walraven, Daniël & Laenen, Ben & D’haeseleer, William, 2015. "Minimizing the levelized cost of electricity production from low-temperature geothermal heat sources with ORCs: Water or air cooled?," Applied Energy, Elsevier, vol. 142(C), pages 144-153.
- Ehsan, M. Monjurul & Guan, Zhiqiang & Gurgenci, Hal & Klimenko, Alexander, 2020. "Feasibility of dry cooling in supercritical CO2 power cycle in concentrated solar power application: Review and a case study," Renewable and Sustainable Energy Reviews, Elsevier, vol. 132(C).
- Xue, Qi & Jin, Xinqiao & Jia, Zhiyang & Lyu, Yuan & Du, Zhimin, 2024. "Optimal control strategy of multiple chiller system based on background knowledge graph," Applied Energy, Elsevier, vol. 375(C).
- Li, Xiaoen & Wang, Ningling & Wang, Ligang & Yang, Yongping & Maréchal, François, 2018. "Identification of optimal operating strategy of direct air-cooling condenser for Rankine cycle based power plants," Applied Energy, Elsevier, vol. 209(C), pages 153-166.
- Xin-gang, Zhao & Gui-wu, Jiang & Ang, Li & Yun, Li, 2016. "Technology, cost, a performance of waste-to-energy incineration industry in China," Renewable and Sustainable Energy Reviews, Elsevier, vol. 55(C), pages 115-130.
- Yu, F.W. & Chan, K.T., 2010. "Simulation and electricity savings estimation of air-cooled centrifugal chiller system with mist pre-cooling," Applied Energy, Elsevier, vol. 87(4), pages 1198-1206, April.
- Lozano-Santamaria, Federico & Luceño, José A. & Martín, Mariano & Macchietto, Sandro, 2020. "Stochastic modelling of sandstorms affecting the optimal operation and cleaning scheduling of air coolers in concentrated solar power plants," Energy, Elsevier, vol. 213(C).
- Comakli, K. & Simsek, F. & Comakli, O. & Sahin, B., 2009. "Determination of optimum working conditions R22 and R404A refrigerant mixtures in heat-pumps using Taguchi method," Applied Energy, Elsevier, vol. 86(11), pages 2451-2458, November.
- Zhou, Guobing & Zhang, Yufeng, 2010. "Performance of a split-type air conditioner matched with coiled adiabatic capillary tubes using HCFC22 and HC290," Applied Energy, Elsevier, vol. 87(5), pages 1522-1528, May.
More about this item
Keywords
Air-cooled condenser; Finned tube bundle; Thermo-flow performances; Wind speed and direction; Hot plume recirculation; Trapezoidal array;All these keywords.
Statistics
Access and download statisticsCorrections
All material on this site has been provided by the respective publishers and authors. You can help correct errors and omissions. When requesting a correction, please mention this item's handle: RePEc:eee:appene:v:99:y:2012:i:c:p:402-413. See general information about how to correct material in RePEc.
If you have authored this item and are not yet registered with RePEc, we encourage you to do it here. This allows to link your profile to this item. It also allows you to accept potential citations to this item that we are uncertain about.
If CitEc recognized a bibliographic reference but did not link an item in RePEc to it, you can help with this form .
If you know of missing items citing this one, you can help us creating those links by adding the relevant references in the same way as above, for each refering item. If you are a registered author of this item, you may also want to check the "citations" tab in your RePEc Author Service profile, as there may be some citations waiting for confirmation.
For technical questions regarding this item, or to correct its authors, title, abstract, bibliographic or download information, contact: Catherine Liu (email available below). General contact details of provider: http://www.elsevier.com/wps/find/journaldescription.cws_home/405891/description#description .
Please note that corrections may take a couple of weeks to filter through the various RePEc services.