Comparative Modelling Analysis of Air Pollutants, PM 2.5 and Energy Efficiency Using Three Ventilation Strategies in a High-Rise Building: A Case Study in Suzhou, China

Author

Listed:
  • Nuodi Fu

    (Department of Architecture, Xi’an Jiaotong—Liverpool University, Suzhou 215123, China
    School of Architecture, University of Liverpool, Liverpool L69 7ZN, UK)

  • Moon Keun Kim

    (Department of Civil Engineering and Energy Technology, Oslo Metropolitan University, 0130 Oslo, Norway)

  • Bing Chen

    (Department of Urban Planning and Design, Xi’an Jiaotong—Liverpool University, Suzhou 215123, China)

  • Stephen Sharples

    (School of Architecture, University of Liverpool, Liverpool L69 7ZN, UK)

Abstract

This study investigated the ventilation efficiency and energy performance of three ventilation strategies—an all-air system (AAS), a radiant panel system with a displacement ventilation system (DPS), and a radiant panel system with a decentralized ventilation system (DVS). The research analyzed the indoor air quality (IAQ) in a high-rise building based on the building’s height, the air handling unit (AHU) location, air infiltration rate, outdoor air pollution rate, seasonal change, and air filter efficiency. The results indicated that the AAS had the best performance in terms of IAQ in the high-rise building in winter; however, the AAS also had the highest annual energy demand. For the same conditions, the DVS consumed less energy but had the worst performance in maintaining a satisfactory IAQ. Considering energy consumption, it is worth developing the DVS further to improve ventilation performance. By applying a double-filter system on the lower floors in a high-rise building, the DVS’s ventilation performance was dramatically improved while at the same time consuming less energy than the original DPS and AAS. The application of DVS can also minimize the negative effect of the infiltration rate on indoor air quality (IAQ) in a building, which means that the DVS can better maintain IAQ within a healthy range for a more extended period. Moreover, it was found that the DVS still had a substantial potential for saving energy during the season when the outdoor air was relatively clean. Hence, it is highly recommended that the DVS is used in high-rise buildings.

Suggested Citation

  • Nuodi Fu & Moon Keun Kim & Bing Chen & Stephen Sharples, 2021. "Comparative Modelling Analysis of Air Pollutants, PM 2.5 and Energy Efficiency Using Three Ventilation Strategies in a High-Rise Building: A Case Study in Suzhou, China," Sustainability, MDPI, vol. 13(15), pages 1-20, July.
  • Handle: RePEc:gam:jsusta:v:13:y:2021:i:15:p:8453-:d:603728
    as

    Download full text from publisher

    File URL: https://www.mdpi.com/2071-1050/13/15/8453/pdf
    Download Restriction: no

    File URL: https://www.mdpi.com/2071-1050/13/15/8453/
    Download Restriction: no
    ---><---

    References listed on IDEAS

    as
    1. Zhang, L.Z & Niu, J.L, 2001. "Energy requirements for conditioning fresh air and the long-term savings with a membrane-based energy recovery ventilator in Hong Kong," Energy, Elsevier, vol. 26(2), pages 119-135.
    2. Liu, X.P. & Niu, J.L., 2014. "An optimal design analysis method for heat recovery devices in building applications," Applied Energy, Elsevier, vol. 129(C), pages 364-372.
    3. Alexander Rieser & Rainer Pfluger & Alexandra Troi & Daniel Herrera-Avellanosa & Kirsten Engelund Thomsen & Jørgen Rose & Zeynep Durmuş Arsan & Gulden Gokcen Akkurt & Gerhard Kopeinig & Gaëlle Guyot &, 2021. "Integration of Energy-Efficient Ventilation Systems in Historic Buildings—Review and Proposal of a Systematic Intervention Approach," Sustainability, MDPI, vol. 13(4), pages 1-21, February.
    4. Chong Zhang & Jinbo Wang & Liao Li & Feifei Wang & Wenjie Gang, 2020. "Utilization of Earth-to-Air Heat Exchanger to Pre-Cool/Heat Ventilation Air and Its Annual Energy Performance Evaluation: A Case Study," Sustainability, MDPI, vol. 12(20), pages 1-17, October.
    5. Zhen Peng & Wu Deng & Rosangela Tenorio, 2017. "Investigation of Indoor Air Quality and the Identification of Influential Factors at Primary Schools in the North of China," Sustainability, MDPI, vol. 9(7), pages 1-14, July.
    Full references (including those not matched with items on IDEAS)

    Most related items

    These are the items that most often cite the same works as this one and are cited by the same works as this one.
    1. Mahsa Tashakor & Reza Dahmardeh Behrooz & Seyed Reza Asvad & Dimitris G. Kaskaoutis, 2022. "Tracing of Heavy Metals Embedded in Indoor Dust Particles from the Industrial City of Asaluyeh, South of Iran," IJERPH, MDPI, vol. 19(13), pages 1-19, June.
    2. Carla Balocco & Lorenzo Leoncini, 2020. "Energy Cost for Effective Ventilation and Air Quality for Healthy Buildings: Plant Proposals for a Historic Building School Reopening in the Covid-19 Era," Sustainability, MDPI, vol. 12(20), pages 1-16, October.
    3. Eleonora Laurini & Mariangela De Vita & Pierluigi De Berardinis, 2021. "Monitoring the Indoor Air Quality: A Case Study of Passive Cooling from Historical Hypogeal Rooms," Energies, MDPI, vol. 14(9), pages 1-15, April.
    4. Alessia Buda & Ernst Jan de Place Hansen & Alexander Rieser & Emanuela Giancola & Valeria Natalina Pracchi & Sara Mauri & Valentina Marincioni & Virginia Gori & Kalliopi Fouseki & Cristina S. Polo Lóp, 2021. "Conservation-Compatible Retrofit Solutions in Historic Buildings: An Integrated Approach," Sustainability, MDPI, vol. 13(5), pages 1-19, March.
    5. Zhang, Li-Zhi, 2016. "A reliability-based optimization of membrane-type total heat exchangers under uncertain design parameters," Energy, Elsevier, vol. 101(C), pages 390-401.
    6. Luo, Yimo & Wang, Meng & Yang, Hongxing & Lu, Lin & Peng, Jinqing, 2015. "Experimental study of the film thickness in the dehumidifier of a liquid desiccant air conditioning system," Energy, Elsevier, vol. 84(C), pages 239-246.
    7. Shen, Suping & Cai, Wenjian & Wang, Xinli & Wu, Qiong & Yon, Haoren, 2017. "Investigation of liquid desiccant regenerator with fixed-plate heat recovery system," Energy, Elsevier, vol. 137(C), pages 172-182.
    8. Cristina S. Polo López & Elena Lucchi & Eleonora Leonardi & Antonello Durante & Anne Schmidt & Roger Curtis, 2021. "Risk-Benefit Assessment Scheme for Renewable Solar Solutions in Traditional and Historic Buildings," Sustainability, MDPI, vol. 13(9), pages 1-35, May.
    9. Elombo Motoula, Smaël Magloire & Gomat, Landry Jean Pierre & Lin, Jian & M’passi Mabiala, Bernard, 2022. "Continuum approach to evaluate humidity transportation by an Earth to Air Energy Exchanger," Renewable and Sustainable Energy Reviews, Elsevier, vol. 165(C).
    10. Liu, Di & Zhao, Fu-Yun & Tang, Guang-Fa, 2010. "Active low-grade energy recovery potential for building energy conservation," Renewable and Sustainable Energy Reviews, Elsevier, vol. 14(9), pages 2736-2747, December.
    11. Fusheng Ma & Changhong Zhan & Xiaoyang Xu, 2019. "Investigation and Evaluation of Winter Indoor Air Quality of Primary Schools in Severe Cold Weather Areas of China," Energies, MDPI, vol. 12(9), pages 1-19, April.
    12. Shen, Suping & Cai, Wenjian & Wang, Xinli & Wu, Qiong & Yon, Haoren, 2016. "Hybrid model for heat recovery heat pipe system in Liquid Desiccant Dehumidification System," Applied Energy, Elsevier, vol. 182(C), pages 383-393.
    13. Bao, Lingling & Wang, Jinggang & Yang, Hongxing, 2016. "Investigation on the performance of a heat recovery ventilator in different climate regions in China," Energy, Elsevier, vol. 104(C), pages 85-98.
    14. Gaetano Settimo & Luciana Indinnimeo & Marco Inglessis & Marco De Felice & Roberta Morlino & Annalisa di Coste & Alessandra Fratianni & Pasquale Avino, 2020. "Indoor Air Quality Levels in Schools: Role of Student Activities and No Activities," IJERPH, MDPI, vol. 17(18), pages 1-17, September.
    15. Jolanda Palmisani & Alessia Di Gilio & Ezia Cisternino & Maria Tutino & Gianluigi de Gennaro, 2020. "Volatile Organic Compound (VOC) Emissions from a Personal Care Polymer-Based Item: Simulation of the Inhalation Exposure Scenario Indoors under Actual Conditions of Use," Sustainability, MDPI, vol. 12(7), pages 1-13, March.
    16. Vinh Van Tran & Duckshin Park & Young-Chul Lee, 2020. "Indoor Air Pollution, Related Human Diseases, and Recent Trends in the Control and Improvement of Indoor Air Quality," IJERPH, MDPI, vol. 17(8), pages 1-27, April.
    17. Armando Pelliccioni & Paolo Monti & Giorgio Cattani & Fabio Boccuni & Marco Cacciani & Silvia Canepari & Pasquale Capone & Maria Catrambone & Mariacarmela Cusano & Maria Concetta D’Ovidio & Antonella , 2020. "Integrated Evaluation of Indoor Particulate Exposure: The VIEPI Project," Sustainability, MDPI, vol. 12(22), pages 1-25, November.
    18. Nuno Baía Saraiva & Luisa Dias Pereira & Adélio Rodrigues Gaspar & José Joaquim da Costa, 2021. "Barriers on Establishing Passive Strategies in Office Spaces: A Case Study in a Historic University Building," Sustainability, MDPI, vol. 13(8), pages 1-15, April.
    19. Albdoor, Ahmed K. & Ma, Zhenjun & Cooper, Paul & Ren, Haoshan & Al-Ghazzawi, Fatimah, 2020. "Thermodynamic analysis and design optimisation of a cross flow air to air membrane enthalpy exchanger," Energy, Elsevier, vol. 202(C).
    20. Carla Balocco & Alessandro Colaianni, 2018. "Assessment of Energy Sustainable Operations on a Historical Building. The Dante Alighieri High School in Florence," Sustainability, MDPI, vol. 10(6), pages 1-24, June.

    Corrections

    All material on this site has been provided by the respective publishers and authors. You can help correct errors and omissions. When requesting a correction, please mention this item's handle: RePEc:gam:jsusta:v:13:y:2021:i:15:p:8453-:d:603728. See general information about how to correct material in RePEc.

    If you have authored this item and are not yet registered with RePEc, we encourage you to do it here. This allows to link your profile to this item. It also allows you to accept potential citations to this item that we are uncertain about.

    If CitEc recognized a bibliographic reference but did not link an item in RePEc to it, you can help with this form .

    If you know of missing items citing this one, you can help us creating those links by adding the relevant references in the same way as above, for each refering item. If you are a registered author of this item, you may also want to check the "citations" tab in your RePEc Author Service profile, as there may be some citations waiting for confirmation.

    For technical questions regarding this item, or to correct its authors, title, abstract, bibliographic or download information, contact: MDPI Indexing Manager (email available below). General contact details of provider: https://www.mdpi.com .

    Please note that corrections may take a couple of weeks to filter through the various RePEc services.

    IDEAS is a RePEc service. RePEc uses bibliographic data supplied by the respective publishers.