IDEAS home Printed from https://ideas.repec.org/a/eee/renene/v210y2023icp640-655.html
   My bibliography  Save this article

Long-term performance of a subway source heat pump system with two types of front-end heat exchangers

Author

Listed:
  • Ji, Yongming
  • Yin, Zhenfeng
  • Jiao, Jiachen
  • Hu, Songtao

Abstract

The rapid development of subways and resulting deterioration of the thermal environment in tunnels have led to thermal pollution of underground spaces, which is a problem that cannot be ignored. The subway source heat pump system (SSHPS) with a tunnel-lining capillary heat exchanger (CHE) is an effective technology for solving this problem. Existing researches mainly focused on the short-term performance of the SSHPS. Few studies have analyzed the long-term performance of the system under complex periodic boundary conditions. In this study, a simulation model of an SSHPS, which conforms to an actual demonstration project located in Lingshanwei Subway Station of Qingdao Metro Line 13, was built by coupling a flat CHE for the open-cut section and a circular CHE for the concealed excavation section of a subway tunnel. Field test results of the SSHPS performance were compared with those of the simulation. The maximum relative error is 13.96%, which shows that the simulation model has high accuracy and can satisfy the requirements of practical engineering applications. Based on the verified model, the system performance under complex periodic boundary conditions was simulated for 10 consecutive years. The results indicate that the average heat flux of the flat and circular CHEs has little variation during the continuous operation of the system for 10 years, and the variations during the cooling and heating seasons are less than 1.24 W/m2 and 0.36 W/m2, respectively. The annual air temperature increments in the tunnel with flat and circular CHEs are approximately 0.226 °C and 0.324 °C, respectively. The average coefficients of performance of the heat pump unit in the cooling and heating seasons are 4.43 and 5.11, respectively, indicating that the heat pump unit operates efficiently throughout the year. The main reason for the long-term high performance of SSHPS is the annual thermal balance of the subway tunnel. The thermal balance of the subway tunnel during long-term operation should be considered when designing an SSHPS system. This study can provide a reference for optimizing the design and operation of the SSHPS.

Suggested Citation

  • Ji, Yongming & Yin, Zhenfeng & Jiao, Jiachen & Hu, Songtao, 2023. "Long-term performance of a subway source heat pump system with two types of front-end heat exchangers," Renewable Energy, Elsevier, vol. 210(C), pages 640-655.
  • Handle: RePEc:eee:renene:v:210:y:2023:i:c:p:640-655
    DOI: 10.1016/j.renene.2023.04.079
    as

    Download full text from publisher

    File URL: http://www.sciencedirect.com/science/article/pii/S0960148123005293
    Download Restriction: Full text for ScienceDirect subscribers only

    File URL: https://libkey.io/10.1016/j.renene.2023.04.079?utm_source=ideas
    LibKey link: if access is restricted and if your library uses this service, LibKey will redirect you to where you can use your library subscription to access this item
    ---><---

    As the access to this document is restricted, you may want to search for a different version of it.

    References listed on IDEAS

    as
    1. Tong, Li & Liu, Nan & Hu, Songtao & Ji, Yongming & Lu, Shan & Liu, Guodan & Tong, Zhen, 2021. "Study on key design parameters of subway source heat pump system with capillary exchanger," Renewable Energy, Elsevier, vol. 164(C), pages 183-193.
    2. Liu, Guodan & Li, Chuanrui & Hu, Songtao & Ji, Yongming & Tong, Zhen & Wang, Yimei & Tong, Li & Mao, Zhu & Lu, Shan, 2020. "Study on heat transfer model of capillary exchanger in subway source heat pump system," Renewable Energy, Elsevier, vol. 150(C), pages 1074-1088.
    3. Ji, Yongming & Wu, Wenze & Hu, Songtao, 2023. "Long-term performance of a front-end capillary heat exchanger for a metro source heat pump system," Applied Energy, Elsevier, vol. 335(C).
    Full references (including those not matched with items on IDEAS)

    Most related items

    These are the items that most often cite the same works as this one and are cited by the same works as this one.
    1. Ji, Yongming & Wu, Wenze & Qi, Haoyu & Wang, Wenqiang & Hu, Songtao, 2022. "Heat transfer performance analysis of front-end capillary heat exchanger of a subway source heat pump system," Energy, Elsevier, vol. 246(C).
    2. Ji, Yongming & Wu, Wenze & Hu, Songtao, 2023. "Long-term performance of a front-end capillary heat exchanger for a metro source heat pump system," Applied Energy, Elsevier, vol. 335(C).
    3. Ji, Yongming & Wang, Wenqiang & Fan, Yujing & Hu, Songtao, 2023. "Coupling effect between tunnel lining heat exchanger and subway thermal environment," Renewable Energy, Elsevier, vol. 217(C).
    4. Wang, Jing & Mao, Jinfeng & Han, Xu & Li, Yong, 2021. "Study on analytical solution model of heat transfer of ground heat exchanger in the protection engineering structure," Renewable Energy, Elsevier, vol. 179(C), pages 998-1008.
    5. Zheng, Wandong & Yin, Hao & Li, Bojia & Zhang, Huan & Jurasz, Jakub & Zhong, Lei, 2022. "Heating performance and spatial analysis of seawater-source heat pump with staggered tube-bundle heat exchanger," Applied Energy, Elsevier, vol. 305(C).
    6. Konstantin Osintsev & Sergei Aliukov & Sulpan Kuskarbekova & Tatyana Tarasova & Aleksandr Karelin & Vladimir Konchakov & Olga Kornyakova, 2023. "Increasing Thermal Efficiency: Methods, Case Studies, and Integration of Heat Exchangers with Renewable Energy Sources and Heat Pumps for Desalination," Energies, MDPI, vol. 16(13), pages 1-36, June.
    7. Yu, Yanzhe & You, Shijun & Zhang, Huan & Ye, Tianzhen & Wang, Yaran & Wei, Shen, 2021. "A review on available energy saving strategies for heating, ventilation and air conditioning in underground metro stations," Renewable and Sustainable Energy Reviews, Elsevier, vol. 141(C).
    8. Jingnan Liu & Lixin Zhang & Yongbao Chen & Zheng Yin & Yan Shen & Yuedong Sun, 2022. "Study of the Technologies for Freeze Protection of Cooling Towers in the Solar System," Energies, MDPI, vol. 15(24), pages 1-11, December.

    Corrections

    All material on this site has been provided by the respective publishers and authors. You can help correct errors and omissions. When requesting a correction, please mention this item's handle: RePEc:eee:renene:v:210:y:2023:i:c:p:640-655. See general information about how to correct material in RePEc.

    If you have authored this item and are not yet registered with RePEc, we encourage you to do it here. This allows to link your profile to this item. It also allows you to accept potential citations to this item that we are uncertain about.

    If CitEc recognized a bibliographic reference but did not link an item in RePEc to it, you can help with this form .

    If you know of missing items citing this one, you can help us creating those links by adding the relevant references in the same way as above, for each refering item. If you are a registered author of this item, you may also want to check the "citations" tab in your RePEc Author Service profile, as there may be some citations waiting for confirmation.

    For technical questions regarding this item, or to correct its authors, title, abstract, bibliographic or download information, contact: Catherine Liu (email available below). General contact details of provider: http://www.journals.elsevier.com/renewable-energy .

    Please note that corrections may take a couple of weeks to filter through the various RePEc services.

    IDEAS is a RePEc service. RePEc uses bibliographic data supplied by the respective publishers.