Experimental analysis of a ground source heat pump in a residential installation after two years in operation

Author

Listed:
  • Aira, Roberto
  • Fernández-Seara, José
  • Diz, Rubén
  • Pardiñas, Ángel Á.

Abstract

An experimental analysis was carried out in an installation with inverter operated ground source heat pump (GSHP) used for space heating with low temperature radiators, domestic hot water (DHW) production and pool heating at a single-family house during two years. The percentage contribution of each of the modes of operation are heating mode (86.5% on average) followed by pool heating (9.8% on average) and DHW production (3.7% on average). In heating mode, it was shown that the supplied temperature in the heating circuit that yields the best performance is 50 °C, since it is the lowest temperature at which the heat pump operates continuously. This work contributes to the literature with a database of actual and continuous data for 2 years. It includes the power consumption of the heat pump, the behaviour of the borehole for 2 years and the number of starts/stops and times of operation of the heat pump in each operating mode. COPs and SPFs have also been determined. During the first year the average SPF is 3.94 in heating mode, 3.24 in DHW mode and 4.11 in pool mode. In the second year 3.39 in heating mode, 3.21 in DHW mode and 4.18 in pool mode.

Suggested Citation

  • Aira, Roberto & Fernández-Seara, José & Diz, Rubén & Pardiñas, Ángel Á., 2017. "Experimental analysis of a ground source heat pump in a residential installation after two years in operation," Renewable Energy, Elsevier, vol. 114(PB), pages 1214-1223.
  • Handle: RePEc:eee:renene:v:114:y:2017:i:pb:p:1214-1223
    DOI: 10.1016/j.renene.2017.07.099
    as

    Download full text from publisher

    File URL: http://www.sciencedirect.com/science/article/pii/S0960148117307267
    Download Restriction: Full text for ScienceDirect subscribers only

    File URL: https://libkey.io/10.1016/j.renene.2017.07.099?utm_source=ideas
    LibKey link: if access is restricted and if your library uses this service, LibKey will redirect you to where you can use your library subscription to access this item
    ---><---

    As the access to this document is restricted, you may want to search for a different version of it.

    References listed on IDEAS

    as
    1. Barbier, Enrico, 1997. "Nature and technology of geothermal energy: A review," Renewable and Sustainable Energy Reviews, Elsevier, vol. 1(1-2), pages 1-69, March.
    2. Etemoglu, A.B. & Can, M., 2007. "Classification of geothermal resources in Turkey by exergy analysis," Renewable and Sustainable Energy Reviews, Elsevier, vol. 11(7), pages 1596-1606, September.
    3. Hwang, Yujin & Lee, Jae-Keun & Jeong, Young-Man & Koo, Kyung-Min & Lee, Dong-Hyuk & Kim, In-Kyu & Jin, Sim-Won & Kim, Soo H., 2009. "Cooling performance of a vertical ground-coupled heat pump system installed in a school building," Renewable Energy, Elsevier, vol. 34(3), pages 578-582.
    4. Ozyurt, Omer & Ekinci, Dundar Arif, 2011. "Experimental study of vertical ground-source heat pump performance evaluation for cold climate in Turkey," Applied Energy, Elsevier, vol. 88(4), pages 1257-1265, April.
    5. Sharqawy, Mostafa H. & Said, S.A. & Mokheimer, E.M. & Habib, M.A. & Badr, H.M. & Al-Shayea, N.A., 2009. "First in situ determination of the ground thermal conductivity for boreholeheat exchanger applications in Saudi Arabia," Renewable Energy, Elsevier, vol. 34(10), pages 2218-2223.
    6. Lee, Jin-Yong, 2009. "Current status of ground source heat pumps in Korea," Renewable and Sustainable Energy Reviews, Elsevier, vol. 13(6-7), pages 1560-1568, August.
    7. Retkowski, Waldemar & Thöming, Jorg, 2014. "Thermoeconomic optimization of vertical ground-source heat pump systems through nonlinear integer programming," Applied Energy, Elsevier, vol. 114(C), pages 492-503.
    8. Lund, John W., 2003. "Direct-use of geothermal energy in the USA," Applied Energy, Elsevier, vol. 74(1-2), pages 33-42, January.
    9. Petit, P.J. & Meyer, J.P., 1998. "Economic potential of vertical ground-source heat pumps compared to air-source air conditioners in South Africa," Energy, Elsevier, vol. 23(2), pages 137-143.
    10. Man, Yi & Yang, Hongxing & Wang, Jinggang & Fang, Zhaohong, 2012. "In situ operation performance test of ground coupled heat pump system for cooling and heating provision in temperate zone," Applied Energy, Elsevier, vol. 97(C), pages 913-920.
    11. Esen, Hikmet & Inalli, Mustafa & Sengur, Abdulkadir & Esen, Mehmet, 2008. "Modeling a ground-coupled heat pump system by a support vector machine," Renewable Energy, Elsevier, vol. 33(8), pages 1814-1823.
    12. Bayer, Peter & Saner, Dominik & Bolay, Stephan & Rybach, Ladislaus & Blum, Philipp, 2012. "Greenhouse gas emission savings of ground source heat pump systems in Europe: A review," Renewable and Sustainable Energy Reviews, Elsevier, vol. 16(2), pages 1256-1267.
    13. Yang, H. & Cui, P. & Fang, Z., 2010. "Vertical-borehole ground-coupled heat pumps: A review of models and systems," Applied Energy, Elsevier, vol. 87(1), pages 16-27, January.
    14. Pulat, Erhan & Coskun, Salih & Unlu, Kursat & Yamankaradeniz, Nurettin, 2009. "Experimental study of horizontal ground source heat pump performance for mild climate in Turkey," Energy, Elsevier, vol. 34(9), pages 1284-1295.
    15. Yang, Weibo & Shi, Mingheng & Liu, Guangyuan & Chen, Zhenqian, 2009. "A two-region simulation model of vertical U-tube ground heat exchanger and its experimental verification," Applied Energy, Elsevier, vol. 86(10), pages 2005-2012, October.
    16. Wagner, Valentin & Bayer, Peter & Kübert, Markus & Blum, Philipp, 2012. "Numerical sensitivity study of thermal response tests," Renewable Energy, Elsevier, vol. 41(C), pages 245-253.
    Full references (including those not matched with items on IDEAS)

    Citations

    Citations are extracted by the CitEc Project, subscribe to its RSS feed for this item.
    as


    Cited by:

    1. Li, Chao & Jiang, Chao & Guan, Yanling, 2022. "An analytical model for heat transfer characteristics of a deep-buried U-bend pipe and its heat transfer performance under different deflecting angles," Energy, Elsevier, vol. 244(PA).
    2. Wang, Y. & Wang, J. & He, W., 2022. "Development of efficient, flexible and affordable heat pumps for supporting heat and power decarbonisation in the UK and beyond: Review and perspectives," Renewable and Sustainable Energy Reviews, Elsevier, vol. 154(C).
    3. Li, Chao & Guan, Yanling & Liu, Jianhong & Jiang, Chao & Yang, Ruitao & Hou, Xueming, 2020. "Heat transfer performance of a deep ground heat exchanger for building heating in long-term service," Renewable Energy, Elsevier, vol. 166(C), pages 20-34.
    4. Andrzej Gajewski & Katarzyna Gładyszewska-Fiedoruk & Dorota Anna Krawczyk, 2019. "Carbon Dioxide Emissions during Air, Ground, or Groundwater Heat Pump Performance in Białystok," Sustainability, MDPI, vol. 11(18), pages 1-16, September.

    Most related items

    These are the items that most often cite the same works as this one and are cited by the same works as this one.
    1. Sebarchievici, Calin & Sarbu, Ioan, 2015. "Performance of an experimental ground-coupled heat pump system for heating, cooling and domestic hot-water operation," Renewable Energy, Elsevier, vol. 76(C), pages 148-159.
    2. Ioan Sarbu & Calin Sebarchievici, 2016. "Performance Evaluation of Radiator and Radiant Floor Heating Systems for an Office Room Connected to a Ground-Coupled Heat Pump," Energies, MDPI, vol. 9(4), pages 1-19, March.
    3. Ioan Sarbu & Calin Sebarchievici, 2020. "Exploratory Research to Improve Energy-Efficiency of a Ground-Coupled Heat Pump Utilizing an Automatic Control Device of Circulation Pump Speed," Energies, MDPI, vol. 13(19), pages 1-19, September.
    4. Man, Yi & Yang, Hongxing & Wang, Jinggang & Fang, Zhaohong, 2012. "In situ operation performance test of ground coupled heat pump system for cooling and heating provision in temperate zone," Applied Energy, Elsevier, vol. 97(C), pages 913-920.
    5. Michopoulos, A. & Zachariadis, T. & Kyriakis, N., 2013. "Operation characteristics and experience of a ground source heat pump system with a vertical ground heat exchanger," Energy, Elsevier, vol. 51(C), pages 349-357.
    6. Li, Min & Lai, Alvin C.K., 2015. "Review of analytical models for heat transfer by vertical ground heat exchangers (GHEs): A perspective of time and space scales," Applied Energy, Elsevier, vol. 151(C), pages 178-191.
    7. Sivasakthivel, T. & Murugesan, K. & Sahoo, P.K., 2015. "Study of technical, economical and environmental viability of ground source heat pump system for Himalayan cities of India," Renewable and Sustainable Energy Reviews, Elsevier, vol. 48(C), pages 452-462.
    8. Zhang, Changxing & Guo, Zhanjun & Liu, Yufeng & Cong, Xiaochun & Peng, Donggen, 2014. "A review on thermal response test of ground-coupled heat pump systems," Renewable and Sustainable Energy Reviews, Elsevier, vol. 40(C), pages 851-867.
    9. Soni, Suresh Kumar & Pandey, Mukesh & Bartaria, Vishvendra Nath, 2016. "Hybrid ground coupled heat exchanger systems for space heating/cooling applications: A review," Renewable and Sustainable Energy Reviews, Elsevier, vol. 60(C), pages 724-738.
    10. Sivasakthivel, T. & Murugesan, K. & Sahoo, P.K., 2014. "A study on energy and CO2 saving potential of ground source heat pump system in India," Renewable and Sustainable Energy Reviews, Elsevier, vol. 32(C), pages 278-293.
    11. Cui, Yuanlong & Zhu, Jie & Twaha, Ssennoga & Riffat, Saffa, 2018. "A comprehensive review on 2D and 3D models of vertical ground heat exchangers," Renewable and Sustainable Energy Reviews, Elsevier, vol. 94(C), pages 84-114.
    12. Wilke, Sascha & Menberg, Kathrin & Steger, Hagen & Blum, Philipp, 2020. "Advanced thermal response tests: A review," Renewable and Sustainable Energy Reviews, Elsevier, vol. 119(C).
    13. Somogyi, Viola & Sebestyén, Viktor & Nagy, Georgina, 2017. "Scientific achievements and regulation of shallow geothermal systems in six European countries – A review," Renewable and Sustainable Energy Reviews, Elsevier, vol. 68(P2), pages 934-952.
    14. Blum, Philipp & Campillo, Gisela & Kölbel, Thomas, 2011. "Techno-economic and spatial analysis of vertical ground source heat pump systems in Germany," Energy, Elsevier, vol. 36(5), pages 3002-3011.
    15. Atwany, Hanin & Hamdan, Mohammad O. & Abu-Nabah, Bassam A. & Alami, Abdul Hai & Attom, Mousa, 2020. "Experimental evaluation of ground heat exchanger in UAE," Renewable Energy, Elsevier, vol. 159(C), pages 538-546.
    16. Bagdanavicius, Audrius & Jenkins, Nick, 2013. "Power requirements of ground source heat pumps in a residential area," Applied Energy, Elsevier, vol. 102(C), pages 591-600.
    17. Dusseault, Bernard & Pasquier, Philippe, 2021. "Usage of the net present value-at-risk to design ground-coupled heat pump systems under uncertain scenarios," Renewable Energy, Elsevier, vol. 173(C), pages 953-971.
    18. Karytsas, Spyridon & Choropanitis, Ioannis, 2017. "Barriers against and actions towards renewable energy technologies diffusion: A Principal Component Analysis for residential ground source heat pump (GSHP) systems," Renewable and Sustainable Energy Reviews, Elsevier, vol. 78(C), pages 252-271.
    19. Javadi, Hossein & Mousavi Ajarostaghi, Seyed Soheil & Rosen, Marc A. & Pourfallah, Mohsen, 2019. "Performance of ground heat exchangers: A comprehensive review of recent advances," Energy, Elsevier, vol. 178(C), pages 207-233.
    20. Ozyurt, Omer & Ekinci, Dundar Arif, 2011. "Experimental study of vertical ground-source heat pump performance evaluation for cold climate in Turkey," Applied Energy, Elsevier, vol. 88(4), pages 1257-1265, April.

    Corrections

    All material on this site has been provided by the respective publishers and authors. You can help correct errors and omissions. When requesting a correction, please mention this item's handle: RePEc:eee:renene:v:114:y:2017:i:pb:p:1214-1223. See general information about how to correct material in RePEc.

    If you have authored this item and are not yet registered with RePEc, we encourage you to do it here. This allows to link your profile to this item. It also allows you to accept potential citations to this item that we are uncertain about.

    If CitEc recognized a bibliographic reference but did not link an item in RePEc to it, you can help with this form .

    If you know of missing items citing this one, you can help us creating those links by adding the relevant references in the same way as above, for each refering item. If you are a registered author of this item, you may also want to check the "citations" tab in your RePEc Author Service profile, as there may be some citations waiting for confirmation.

    For technical questions regarding this item, or to correct its authors, title, abstract, bibliographic or download information, contact: Catherine Liu (email available below). General contact details of provider: http://www.journals.elsevier.com/renewable-energy .

    Please note that corrections may take a couple of weeks to filter through the various RePEc services.

    IDEAS is a RePEc service. RePEc uses bibliographic data supplied by the respective publishers.