IDEAS home Printed from https://ideas.repec.org/a/eee/renene/v159y2020icp538-546.html
   My bibliography  Save this article

Experimental evaluation of ground heat exchanger in UAE

Author

Listed:
  • Atwany, Hanin
  • Hamdan, Mohammad O.
  • Abu-Nabah, Bassam A.
  • Alami, Abdul Hai
  • Attom, Mousa

Abstract

In this paper, an experimental investigation is conducted to examine the performance of a ground heat exchanger (GHE) in Sharjah city in the United Arab Emirates (UAE). The paper reports and discusses the results of two shallow geothermal experimental studies. The first study evaluates ground temperature distribution for two boreholes, with depth of 10 m each, over a period of seven months. The ground temperature distribution results have showed that the mean ground temperature is around 32 °C which is 5° higher than the year-average ambient temperature. The second study examines the performance of a GHE under Sharjah city conditions. The GHE is fabricated using a 300 m long plastic pipe with 0.03 m diameter pipe, which has been horizontally buried at 2.5 m below ground surface. The results show that the ground temperature increases due to GHE and that the ground needs around 9 h to dissipate its thermal energy. A mass flow rate of 0.15 kg/s has provided higher heat exchange and higher GHE effectiveness when compared to lower flow rate of 0.0375 kg/s. The GHE effectiveness decreases over time and the rate of drop in effectiveness becomes more pronounced as mass flow rate increases.

Suggested Citation

  • Atwany, Hanin & Hamdan, Mohammad O. & Abu-Nabah, Bassam A. & Alami, Abdul Hai & Attom, Mousa, 2020. "Experimental evaluation of ground heat exchanger in UAE," Renewable Energy, Elsevier, vol. 159(C), pages 538-546.
  • Handle: RePEc:eee:renene:v:159:y:2020:i:c:p:538-546
    DOI: 10.1016/j.renene.2020.06.073
    as

    Download full text from publisher

    File URL: http://www.sciencedirect.com/science/article/pii/S0960148120309836
    Download Restriction: Full text for ScienceDirect subscribers only

    File URL: https://libkey.io/10.1016/j.renene.2020.06.073?utm_source=ideas
    LibKey link: if access is restricted and if your library uses this service, LibKey will redirect you to where you can use your library subscription to access this item
    ---><---

    As the access to this document is restricted, you may want to search for a different version of it.

    References listed on IDEAS

    as
    1. Bakirci, Kadir, 2010. "Evaluation of the performance of a ground-source heat-pump system with series GHE (ground heat exchanger) in the cold climate region," Energy, Elsevier, vol. 35(7), pages 3088-3096.
    2. Hanin Atwany & Mousa Attom & Mohammad O. Hamdan & Bassam A. Abu-Nabah & Abdul Hai Alami, 2018. "Evaluating thermal conductivity of desert sand under different initial physical properties," Journal of Advances in Technology and Engineering Research, A/Professor Akbar A. Khatibi, vol. 4(6), pages 236-240.
    3. Hwang, Yujin & Lee, Jae-Keun & Jeong, Young-Man & Koo, Kyung-Min & Lee, Dong-Hyuk & Kim, In-Kyu & Jin, Sim-Won & Kim, Soo H., 2009. "Cooling performance of a vertical ground-coupled heat pump system installed in a school building," Renewable Energy, Elsevier, vol. 34(3), pages 578-582.
    4. Niu, Fuxin & Yu, Yuebin & Yu, Daihong & Li, Haorong, 2015. "Heat and mass transfer performance analysis and cooling capacity prediction of earth to air heat exchanger," Applied Energy, Elsevier, vol. 137(C), pages 211-221.
    5. Sharqawy, Mostafa H. & Said, S.A. & Mokheimer, E.M. & Habib, M.A. & Badr, H.M. & Al-Shayea, N.A., 2009. "First in situ determination of the ground thermal conductivity for boreholeheat exchanger applications in Saudi Arabia," Renewable Energy, Elsevier, vol. 34(10), pages 2218-2223.
    6. Soni, Suresh Kumar & Pandey, Mukesh & Bartaria, Vishvendra Nath, 2015. "Ground coupled heat exchangers: A review and applications," Renewable and Sustainable Energy Reviews, Elsevier, vol. 47(C), pages 83-92.
    7. Sivasakthivel, T. & Philippe, Mikael & Murugesan, K. & Verma, Vikas & Hu, Pingfang, 2017. "Experimental thermal performance analysis of ground heat exchangers for space heating and cooling applications," Renewable Energy, Elsevier, vol. 113(C), pages 1168-1181.
    8. Jalaluddin, & Miyara, Akio & Tsubaki, Koutaro & Inoue, Shuntaro & Yoshida, Kentaro, 2011. "Experimental study of several types of ground heat exchanger using a steel pile foundation," Renewable Energy, Elsevier, vol. 36(2), pages 764-771.
    9. Florides, G.A. & Pouloupatis, P.D. & Kalogirou, S. & Messaritis, V. & Panayides, I. & Zomeni, Z. & Partasides, G. & Lizides, A. & Sophocleous, E. & Koutsoumpas, K., 2011. "The geothermal characteristics of the ground and the potential of using ground coupled heat pumps in Cyprus," Energy, Elsevier, vol. 36(8), pages 5027-5036.
    10. Pulat, Erhan & Coskun, Salih & Unlu, Kursat & Yamankaradeniz, Nurettin, 2009. "Experimental study of horizontal ground source heat pump performance for mild climate in Turkey," Energy, Elsevier, vol. 34(9), pages 1284-1295.
    11. Naili, Nabiha & Hazami, Majdi & Attar, Issam & Farhat, Abdelhamid, 2013. "In-field performance analysis of ground source cooling system with horizontal ground heat exchanger in Tunisia," Energy, Elsevier, vol. 61(C), pages 319-331.
    Full references (including those not matched with items on IDEAS)

    Citations

    Citations are extracted by the CitEc Project, subscribe to its RSS feed for this item.
    as


    Cited by:

    1. Huu-Quan, Do & Memarian, Amir & Izadi, Mohsen & Shehzad, Sabir Ali, 2020. "Thermal performance and effectiveness of a dual-porous domestic heat exchanger for building heating application," Renewable Energy, Elsevier, vol. 162(C), pages 1874-1889.
    2. Joanna Piotrowska-Woroniak, 2021. "Determination of the Selected Wells Operational Power with Borehole Heat Exchangers Operating in Real Conditions, Based on Experimental Tests," Energies, MDPI, vol. 14(9), pages 1-21, April.
    3. Reshna Raveendran & Ahmed Hassan & Kheira Anissa Tabet Aoul, 2020. "Diagnoses for Potential Enaction of Water–Energy Nexus in Green Building Rating Systems: Case Study of the Pearl Rating System of United Arab Emirates," Energies, MDPI, vol. 13(20), pages 1-17, October.
    4. Joanna Piotrowska-Woroniak & Tomasz Szul & Grzegorz Woroniak, 2023. "Application of a Model Based on Rough Set Theory (RST) for Estimating the Temperature of Brine from Vertical Ground Heat Exchangers (VGHE) Operated with a Heat Pump—A Case Study," Energies, MDPI, vol. 16(20), pages 1-12, October.
    5. Bulmez, A.M. & Ciofoaia, V. & Năstase, G. & Dragomir, G. & Brezeanu, A.I. & Şerban, A., 2022. "An experimental work on the performance of a solar-assisted ground-coupled heat pump using a horizontal ground heat exchanger," Renewable Energy, Elsevier, vol. 183(C), pages 849-865.
    6. Joanna Piotrowska-Woroniak, 2021. "Assessment of Ground Regeneration around Borehole Heat Exchangers between Heating Seasons in Cold Climates: A Case Study in Bialystok (NE, Poland)," Energies, MDPI, vol. 14(16), pages 1-32, August.

    Most related items

    These are the items that most often cite the same works as this one and are cited by the same works as this one.
    1. Javadi, Hossein & Mousavi Ajarostaghi, Seyed Soheil & Rosen, Marc A. & Pourfallah, Mohsen, 2019. "Performance of ground heat exchangers: A comprehensive review of recent advances," Energy, Elsevier, vol. 178(C), pages 207-233.
    2. Ioan Sarbu & Calin Sebarchievici, 2020. "Exploratory Research to Improve Energy-Efficiency of a Ground-Coupled Heat Pump Utilizing an Automatic Control Device of Circulation Pump Speed," Energies, MDPI, vol. 13(19), pages 1-19, September.
    3. Bakirci, Kadir & Colak, Derya, 2012. "Effect of a superheating and sub-cooling heat exchanger to the performance of a ground source heat pump system," Energy, Elsevier, vol. 44(1), pages 996-1004.
    4. Blum, Philipp & Campillo, Gisela & Kölbel, Thomas, 2011. "Techno-economic and spatial analysis of vertical ground source heat pump systems in Germany," Energy, Elsevier, vol. 36(5), pages 3002-3011.
    5. Sebarchievici, Calin & Sarbu, Ioan, 2015. "Performance of an experimental ground-coupled heat pump system for heating, cooling and domestic hot-water operation," Renewable Energy, Elsevier, vol. 76(C), pages 148-159.
    6. Salsuwanda Selamat & Akio Miyara & Keishi Kariya, 2015. "Analysis of Short Time Period of Operation of Horizontal Ground Heat Exchangers," Resources, MDPI, vol. 4(3), pages 1-17, July.
    7. Man, Yi & Yang, Hongxing & Wang, Jinggang & Fang, Zhaohong, 2012. "In situ operation performance test of ground coupled heat pump system for cooling and heating provision in temperate zone," Applied Energy, Elsevier, vol. 97(C), pages 913-920.
    8. Fernández-Seara, José & Pereiro, Alejandro & Bastos, Santiago & Dopazo, J. Alberto, 2012. "Experimental evaluation of a geothermal heat pump for space heating and domestic hot water simultaneous production," Renewable Energy, Elsevier, vol. 48(C), pages 482-488.
    9. Aira, Roberto & Fernández-Seara, José & Diz, Rubén & Pardiñas, Ángel Á., 2017. "Experimental analysis of a ground source heat pump in a residential installation after two years in operation," Renewable Energy, Elsevier, vol. 114(PB), pages 1214-1223.
    10. Gao, Jiajia & Li, Anbang & Xu, Xinhua & Gang, Wenjie & Yan, Tian, 2018. "Ground heat exchangers: Applications, technology integration and potentials for zero energy buildings," Renewable Energy, Elsevier, vol. 128(PA), pages 337-349.
    11. Akhtari, Mohammad Reza & Shayegh, Iman & Karimi, Nader, 2020. "Techno-economic assessment and optimization of a hybrid renewable earth - air heat exchanger coupled with electric boiler, hydrogen, wind and PV configurations," Renewable Energy, Elsevier, vol. 148(C), pages 839-851.
    12. Zhang, Guozhu & Cao, Ziming & Xiao, Suguang & Guo, Yimu & Li, Chenglin, 2022. "A promising technology of cold energy storage using phase change materials to cool tunnels with geothermal hazards," Renewable and Sustainable Energy Reviews, Elsevier, vol. 163(C).
    13. Lyu, Weihua & Li, Xianting & Yan, Shuai & Jiang, Sihang, 2020. "Utilizing shallow geothermal energy to develop an energy efficient HVAC system," Renewable Energy, Elsevier, vol. 147(P1), pages 672-682.
    14. Karytsas, Spyridon & Choropanitis, Ioannis, 2017. "Barriers against and actions towards renewable energy technologies diffusion: A Principal Component Analysis for residential ground source heat pump (GSHP) systems," Renewable and Sustainable Energy Reviews, Elsevier, vol. 78(C), pages 252-271.
    15. Bordoloi, Namrata & Sharma, Aashish & Nautiyal, Himanshu & Goel, Varun, 2018. "An intense review on the latest advancements of Earth Air Heat Exchangers," Renewable and Sustainable Energy Reviews, Elsevier, vol. 89(C), pages 261-280.
    16. Joanna Piotrowska-Woroniak, 2021. "Determination of the Selected Wells Operational Power with Borehole Heat Exchangers Operating in Real Conditions, Based on Experimental Tests," Energies, MDPI, vol. 14(9), pages 1-21, April.
    17. Nam, Yujin & Chae, Ho-Byung, 2014. "Numerical simulation for the optimum design of ground source heat pump system using building foundation as horizontal heat exchanger," Energy, Elsevier, vol. 73(C), pages 933-942.
    18. Li, Min & Lai, Alvin C.K., 2012. "New temperature response functions (G functions) for pile and borehole ground heat exchangers based on composite-medium line-source theory," Energy, Elsevier, vol. 38(1), pages 255-263.
    19. Selamat, Salsuwanda & Miyara, Akio & Kariya, Keishi, 2016. "Numerical study of horizontal ground heat exchangers for design optimization," Renewable Energy, Elsevier, vol. 95(C), pages 561-573.
    20. Rachana Vidhi, 2018. "A Review of Underground Soil and Night Sky as Passive Heat Sink: Design Configurations and Models," Energies, MDPI, vol. 11(11), pages 1-24, October.

    Corrections

    All material on this site has been provided by the respective publishers and authors. You can help correct errors and omissions. When requesting a correction, please mention this item's handle: RePEc:eee:renene:v:159:y:2020:i:c:p:538-546. See general information about how to correct material in RePEc.

    If you have authored this item and are not yet registered with RePEc, we encourage you to do it here. This allows to link your profile to this item. It also allows you to accept potential citations to this item that we are uncertain about.

    If CitEc recognized a bibliographic reference but did not link an item in RePEc to it, you can help with this form .

    If you know of missing items citing this one, you can help us creating those links by adding the relevant references in the same way as above, for each refering item. If you are a registered author of this item, you may also want to check the "citations" tab in your RePEc Author Service profile, as there may be some citations waiting for confirmation.

    For technical questions regarding this item, or to correct its authors, title, abstract, bibliographic or download information, contact: Catherine Liu (email available below). General contact details of provider: http://www.journals.elsevier.com/renewable-energy .

    Please note that corrections may take a couple of weeks to filter through the various RePEc services.

    IDEAS is a RePEc service. RePEc uses bibliographic data supplied by the respective publishers.