IDEAS home Printed from https://ideas.repec.org/a/gam/jsusta/v17y2025i4p1634-d1592327.html
   My bibliography  Save this article

Efficient Development and Utilization of Geothermal Energy: An Analysis of the Operational Strategy for Deep-Buried Pipe-Type Energy Piles Considering Seepage Effects

Author

Listed:
  • Xianglin Liu

    (CCCC-Second-Highway Consultant Co., Ltd., Wuhan 430058, China)

  • Yuhan Tian

    (School of Civil Engineering and Environment, Hubei University of Technology, Wuhan 430068, China)

  • Yongli Liu

    (School of Civil Engineering and Environment, Hubei University of Technology, Wuhan 430068, China)

  • Wen Liu

    (CCCC Wuhan Zhixing International Engineering Consulting Co., Ltd., Wuhan 430014, China)

  • Lifei Zheng

    (School of Civil Engineering and Environment, Hubei University of Technology, Wuhan 430068, China)

  • Xiaoqing Li

    (School of Civil and Hydraulic Engineering, Huazhong University of Science and Technology, Wuhan 430074, China)

Abstract

As a shallow geothermal energy development technology, energy pile contributes to sustainable development. The seepage effect has a positive effect on the heat transfer performance of the energy pile, and the heat transfer efficiency of the energy pile can also be improved by optimizing the operation strategy. Combined with the structural characteristics of the deep-buried energy pile, the heat transfer characteristics of the deep-buried energy pile are analyzed under continuous and intermittent operation conditions, and the effect of seepage on the heat transfer performance is further investigated under the intermittent operation mode. The results show that the long-term operation of the deep-buried energy pile will reduce its heat exchange performance and aggravate the heat accumulation phenomenon inside the pile body, and the intermittent operation can maintain a higher instantaneous heat exchange rate (HER) in the long-term operation compared with the continuous operation. Considering the energy demand, when the intermittent ratio is 5, the average HER of the pile body only decreases by 68.93 W, and the overall energy efficiency of the pile body is improved by 7.7%. Combined with the operating effects of different intermittent ratios, the optimal range of the circulating medium flow rate for deep buried pipe energy piles should be selected from 1.0 m 3 /h to 1.2 m 3 /h. Groundwater seepage can weaken the degree of heat accumulation inside the DBP-EP piles and improve the overall heat exchange efficiency of DBP-EP, and combined with the intermittent operation mode will be able to further alleviate the DBP-EP heat buildup. The two factors promote each other and have a positive impact on the piles, positively affecting the soil’s long-term heat exchange.

Suggested Citation

  • Xianglin Liu & Yuhan Tian & Yongli Liu & Wen Liu & Lifei Zheng & Xiaoqing Li, 2025. "Efficient Development and Utilization of Geothermal Energy: An Analysis of the Operational Strategy for Deep-Buried Pipe-Type Energy Piles Considering Seepage Effects," Sustainability, MDPI, vol. 17(4), pages 1-21, February.
  • Handle: RePEc:gam:jsusta:v:17:y:2025:i:4:p:1634-:d:1592327
    as

    Download full text from publisher

    File URL: https://www.mdpi.com/2071-1050/17/4/1634/pdf
    Download Restriction: no

    File URL: https://www.mdpi.com/2071-1050/17/4/1634/
    Download Restriction: no
    ---><---

    References listed on IDEAS

    as
    1. Shang, Yan & Dong, Ming & Li, Sufen, 2014. "Intermittent experimental study of a vertical ground source heat pump system," Applied Energy, Elsevier, vol. 136(C), pages 628-635.
    2. Fattahian, Makan & Oliaei, Mohammad & Akbari Garakani, Amir & Kiani Fordoei, Mohammad Amir, 2024. "Numerical modeling of high-velocity groundwater flow influence on the thermal-hydraulic characteristics and energy extraction from energy piles," Renewable Energy, Elsevier, vol. 237(PD).
    Full references (including those not matched with items on IDEAS)

    Most related items

    These are the items that most often cite the same works as this one and are cited by the same works as this one.
    1. Choi, Wonjun & Kikumoto, Hideki & Choudhary, Ruchi & Ooka, Ryozo, 2018. "Bayesian inference for thermal response test parameter estimation and uncertainty assessment," Applied Energy, Elsevier, vol. 209(C), pages 306-321.
    2. Choi, Wonjun & Menberg, Kathrin & Kikumoto, Hideki & Heo, Yeonsook & Choudhary, Ruchi & Ooka, Ryozo, 2018. "Bayesian inference of structural error in inverse models of thermal response tests," Applied Energy, Elsevier, vol. 228(C), pages 1473-1485.
    3. Al-Ameen, Yasameen & Ianakiev, Anton & Evans, Robert, 2018. "Recycling construction and industrial landfill waste material for backfill in horizontal ground heat exchanger systems," Energy, Elsevier, vol. 151(C), pages 556-568.
    4. Zhang, Weiyi & Zhou, Haiyang & Bao, Xiaohua & Cui, Hongzhi, 2023. "Outlet water temperature prediction of energy pile based on spatial-temporal feature extraction through CNN–LSTM hybrid model," Energy, Elsevier, vol. 264(C).
    5. Wang, Yubo & Quan, Zhenhua & Zhao, Yaohua & Wang, Lincheng & Jing, Heran, 2022. "Operation mode performance and optimization of a novel coupled air and ground source heat pump system with energy storage: Case study of a hotel building," Renewable Energy, Elsevier, vol. 201(P1), pages 889-903.
    6. Kerme, Esa Dube & Alzahrani, Waleed Saeed & Fung, Alan S. & Leong, Wey H., 2024. "Experimental investigation of ground-source heat pump system coupled to vertical and horizontal ground loops: A case study," Renewable Energy, Elsevier, vol. 236(C).
    7. Han, Chanjuan & Ellett, Kevin M. & Naylor, Shawn & Yu, Xiong (Bill), 2017. "Influence of local geological data on the performance of horizontal ground-coupled heat pump system integrated with building thermal loads," Renewable Energy, Elsevier, vol. 113(C), pages 1046-1055.
    8. Zhou, Zhihua & Wu, Shengwei & Du, Tao & Chen, Guanyi & Zhang, Zhiming & Zuo, Jian & He, Qing, 2016. "The energy-saving effects of ground-coupled heat pump system integrated with borehole free cooling: A study in China," Applied Energy, Elsevier, vol. 182(C), pages 9-19.
    9. Jianan Liu & Hao Yu & Haoran Ji & Kunpeng Zhao & Chaoxian Lv & Peng Li, 2020. "Optimal Operation Strategy of a Community Integrated Energy System Constrained by the Seasonal Balance of Ground Source Heat Pumps," Sustainability, MDPI, vol. 12(11), pages 1-24, June.
    10. Zhao, Zilong & Lin, Yu-Feng & Stumpf, Andrew & Wang, Xinlei, 2022. "Assessing impacts of groundwater on geothermal heat exchangers: A review of methodology and modeling," Renewable Energy, Elsevier, vol. 190(C), pages 121-147.
    11. Kuzmic, Nikola & Law, Ying Lam E. & Dworkin, Seth B., 2016. "Numerical heat transfer comparison study of hybrid and non-hybrid ground source heat pump systems," Applied Energy, Elsevier, vol. 165(C), pages 919-929.
    12. Han, Chanjuan & Yu, Xiong (Bill), 2016. "Performance of a residential ground source heat pump system in sedimentary rock formation," Applied Energy, Elsevier, vol. 164(C), pages 89-98.
    13. Xi, J. & Li, Y. & Liu, M. & Wang, R.Z., 2017. "Study on the thermal effect of the ground heat exchanger of GSHP in the eastern China area," Energy, Elsevier, vol. 141(C), pages 56-65.
    14. You, Tian & Wu, Wei & Shi, Wenxing & Wang, Baolong & Li, Xianting, 2016. "An overview of the problems and solutions of soil thermal imbalance of ground-coupled heat pumps in cold regions," Applied Energy, Elsevier, vol. 177(C), pages 515-536.
    15. Pandey, Navdeep & Murugesan, K. & Thomas, H.R., 2017. "Optimization of ground heat exchangers for space heating and cooling applications using Taguchi method and utility concept," Applied Energy, Elsevier, vol. 190(C), pages 421-438.
    16. Shibin Geng & Yong Li & Xu Han & Huiliang Lian & Hua Zhang, 2016. "Evaluation of Thermal Anomalies in Multi-Boreholes Field Considering the Effects of Groundwater Flow," Sustainability, MDPI, vol. 8(6), pages 1-19, June.
    17. Sivasakthivel, T. & Murugesan, K. & Sahoo, P.K., 2015. "Study of technical, economical and environmental viability of ground source heat pump system for Himalayan cities of India," Renewable and Sustainable Energy Reviews, Elsevier, vol. 48(C), pages 452-462.
    18. She, Xiaohui & Cong, Lin & Nie, Binjian & Leng, Guanghui & Peng, Hao & Chen, Yi & Zhang, Xiaosong & Wen, Tao & Yang, Hongxing & Luo, Yimo, 2018. "Energy-efficient and -economic technologies for air conditioning with vapor compression refrigeration: A comprehensive review," Applied Energy, Elsevier, vol. 232(C), pages 157-186.
    19. You, Tian & Wu, Wei & Yang, Hongxing & Liu, Jiankun & Li, Xianting, 2021. "Hybrid photovoltaic/thermal and ground source heat pump: Review and perspective," Renewable and Sustainable Energy Reviews, Elsevier, vol. 151(C).
    20. Han, Chanjuan & Yu, Xiong (Bill), 2016. "Sensitivity analysis of a vertical geothermal heat pump system," Applied Energy, Elsevier, vol. 170(C), pages 148-160.

    Corrections

    All material on this site has been provided by the respective publishers and authors. You can help correct errors and omissions. When requesting a correction, please mention this item's handle: RePEc:gam:jsusta:v:17:y:2025:i:4:p:1634-:d:1592327. See general information about how to correct material in RePEc.

    If you have authored this item and are not yet registered with RePEc, we encourage you to do it here. This allows to link your profile to this item. It also allows you to accept potential citations to this item that we are uncertain about.

    If CitEc recognized a bibliographic reference but did not link an item in RePEc to it, you can help with this form .

    If you know of missing items citing this one, you can help us creating those links by adding the relevant references in the same way as above, for each refering item. If you are a registered author of this item, you may also want to check the "citations" tab in your RePEc Author Service profile, as there may be some citations waiting for confirmation.

    For technical questions regarding this item, or to correct its authors, title, abstract, bibliographic or download information, contact: MDPI Indexing Manager (email available below). General contact details of provider: https://www.mdpi.com .

    Please note that corrections may take a couple of weeks to filter through the various RePEc services.

    IDEAS is a RePEc service. RePEc uses bibliographic data supplied by the respective publishers.