IDEAS home Printed from https://ideas.repec.org/a/gam/jeners/v9y2016i4p305-d68693.html
   My bibliography  Save this article

Parametric Analysis of a Rotary Type Liquid Desiccant Air Conditioning System

Author

Listed:
  • M. Mujahid Rafique

    (Department of Mechanical Engineering, King Fahd University of Petroleum and Minerals, Dhahran 31261, Saudi Arabia)

  • Shafiqur Rehman

    (Center for Engineering Research, Research Institute, King Fahd University of Petroleum and Minerals, Dhahran 31261, Saudi Arabia)

  • Luai M. Alhems

    (Center for Engineering Research, Research Institute, King Fahd University of Petroleum and Minerals, Dhahran 31261, Saudi Arabia)

  • Aref Lashin

    (Petroleum and Natural Gas Engineering Department, College of Engineering, King Saud University, P.O. Box 800, Riyadh 11421, Saudi Arabia
    Geology Department, Faculty of Science, Benha University, P.O. Box 13518, Benha 345629, Egypt)

Abstract

Now days, air conditioning systems are a must for almost every commercial and residential building to achieve comfortable indoor conditions. The increasing energy demand, and increasing oil prices and pollution levels raise the need for alternative air conditioning systems which can efficiently utilize renewable energy resources. The liquid desiccant-based air conditioning method is pollution free and thermal energy-based cooling techniques can use low grade thermal energy resources like solar energy, waste heat, etc. These systems have an additional advantage of cleaning bacteria and fungi from the air. In this paper, a newly proposed rotary liquid desiccant air conditioning system has been investigated theoretically. Most direct contact liquid desiccant cooling systems have the problem of desiccant carryover which can be eliminated using the proposed system. The effects of various key parameters and climatic conditions on the performance of the system have been evaluated. The results showed that if the key parameters of the system are controlled effectively, the proposed cooling system has the ability to achieve the desired supply air conditions. The system can achieve high coefficient of performance (COP) under different conditions. The dehumidifier has a sensible heat ratio (SHR) in the range of 0.3–0.6 for different design, climatic, and operating conditions. The system can remove latent load efficiently in applications which require good humidity control.

Suggested Citation

  • M. Mujahid Rafique & Shafiqur Rehman & Luai M. Alhems & Aref Lashin, 2016. "Parametric Analysis of a Rotary Type Liquid Desiccant Air Conditioning System," Energies, MDPI, vol. 9(4), pages 1-15, April.
  • Handle: RePEc:gam:jeners:v:9:y:2016:i:4:p:305-:d:68693
    as

    Download full text from publisher

    File URL: https://www.mdpi.com/1996-1073/9/4/305/pdf
    Download Restriction: no

    File URL: https://www.mdpi.com/1996-1073/9/4/305/
    Download Restriction: no
    ---><---

    References listed on IDEAS

    as
    1. M. Mujahid Rafique & Shafiqur Rehman & Aref Lashin & Nassir Al Arifi, 2016. "Analysis of a Solar Cooling System for Climatic Conditions of Five Different Cities of Saudi Arabia," Energies, MDPI, vol. 9(2), pages 1-13, January.
    2. Bergero, Stefano & Chiari, Anna, 2011. "On the performances of a hybrid air-conditioning system in different climatic conditions," Energy, Elsevier, vol. 36(8), pages 5261-5273.
    3. Abdel-Salam, Ahmed H. & Simonson, Carey J., 2016. "State-of-the-art in liquid desiccant air conditioning equipment and systems," Renewable and Sustainable Energy Reviews, Elsevier, vol. 58(C), pages 1152-1183.
    Full references (including those not matched with items on IDEAS)

    Citations

    Citations are extracted by the CitEc Project, subscribe to its RSS feed for this item.
    as


    Cited by:

    1. Giampieri, Alessandro & Ma, Zhiwei & Smallbone, Andrew & Roskilly, Anthony Paul, 2018. "Thermodynamics and economics of liquid desiccants for heating, ventilation and air-conditioning – An overview," Applied Energy, Elsevier, vol. 220(C), pages 455-479.
    2. Elena Belyanovskaya & Miroslav Rimár & Roman D. Lytovchenko & Miroslav Variny & Kostyantyn M. Sukhyy & Oleksandr O. Yeromin & Mikhailo P. Sykhyy & Elena M. Prokopenko & Irina V. Sukha & Mikhailo V. Gu, 2020. "Performance of an Adsorptive Heat-Moisture Regenerator Based on Silica Gel–Sodium Sulphate," Sustainability, MDPI, vol. 12(14), pages 1-15, July.
    3. Yunlong Ma & Suvash C. Saha & Wendy Miller & Lisa Guan, 2017. "Comparison of Different Solar-Assisted Air Conditioning Systems for Australian Office Buildings," Energies, MDPI, vol. 10(10), pages 1-27, September.
    4. Alelyani, Sami M. & Sherbeck, Jonathan A. & Fette, Nicholas W. & Wang, Yuqian & Phelan, Patrick E., 2018. "Assessment of a novel heat-driven cycle to produce shaft power and refrigeration," Applied Energy, Elsevier, vol. 215(C), pages 751-764.
    5. Yunlong Ma & Suvash C. Saha & Wendy Miller & Lisa Guan, 2017. "Parametric Analysis of Design Parameter Effects on the Performance of a Solar Desiccant Evaporative Cooling System in Brisbane, Australia," Energies, MDPI, vol. 10(7), pages 1-22, June.
    6. Wu, X.N. & Ge, T.S. & Dai, Y.J. & Wang, R.Z., 2018. "Review on substrate of solid desiccant dehumidification system," Renewable and Sustainable Energy Reviews, Elsevier, vol. 82(P3), pages 3236-3249.
    7. Shafiqur Rehman & Muhammad M. Rafique & Luai M. Alhems & Md. Mahbub Alam, 2020. "Development and Implementation of Solar Assisted Desiccant Cooling Technology in Developing Countries: A Case of Saudi Arabia," Energies, MDPI, vol. 13(3), pages 1-22, January.
    8. M. Mujahid Rafique & Shafiqur Rehman & Luai M. Alhems & Muhammad Ali Shakir, 2017. "A Liquid Desiccant Enhanced Two Stage Evaporative Cooling System—Development and Performance Evaluation of a Test Rig," Energies, MDPI, vol. 11(1), pages 1-17, December.

    Most related items

    These are the items that most often cite the same works as this one and are cited by the same works as this one.
    1. Gado, Mohamed G. & Ookawara, Shinichi & Nada, Sameh & El-Sharkawy, Ibrahim I., 2021. "Hybrid sorption-vapor compression cooling systems: A comprehensive overview," Renewable and Sustainable Energy Reviews, Elsevier, vol. 143(C).
    2. Drosou, Vassiliki & Kosmopoulos, Panos & Papadopoulos, Agis, 2016. "Solar cooling system using concentrating collectors for office buildings: A case study for Greece," Renewable Energy, Elsevier, vol. 97(C), pages 697-708.
    3. Fekadu, Geleta & Subudhi, Sudhakar, 2018. "Renewable energy for liquid desiccants air conditioning system: A review," Renewable and Sustainable Energy Reviews, Elsevier, vol. 93(C), pages 364-379.
    4. Min-Hwi Kim & Joon-Young Park & Jae-Weon Jeong, 2017. "Energy Saving Potential of a Thermoelectric Heat Pump-Assisted Liquid Desiccant System in a Dedicated Outdoor Air System," Energies, MDPI, vol. 10(9), pages 1-19, September.
    5. Mohammad, Abdulrahman Th. & Bin Mat, Sohif & Sulaiman, M.Y. & Sopian, K. & Al-abidi, Abduljalil A., 2013. "Survey of hybrid liquid desiccant air conditioning systems," Renewable and Sustainable Energy Reviews, Elsevier, vol. 20(C), pages 186-200.
    6. Miliauskas, G. & Maziukienė, M. & Jouhara, H. & Poškas, R., 2019. "Investigation of mass and heat transfer transitional processes of water droplets in wet gas flow in the framework of energy recovery technologies for biofuel combustion and flue gas removal," Energy, Elsevier, vol. 173(C), pages 740-754.
    7. Wen, Tao & Lu, Lin, 2019. "A review of correlations and enhancement approaches for heat and mass transfer in liquid desiccant dehumidification system," Applied Energy, Elsevier, vol. 239(C), pages 757-784.
    8. Song, Xia & Zhang, Lun & Zhang, Xiaosong, 2019. "Analysis of the temperatures of heating and cooling sources and the air states in liquid desiccant dehumidification systems regenerated by return air," Energy, Elsevier, vol. 168(C), pages 651-661.
    9. Su, Wei & Lu, Zhifei & She, Xiaohui & Zhou, Junming & Wang, Feng & Sun, Bo & Zhang, Xiaosong, 2022. "Liquid desiccant regeneration for advanced air conditioning: A comprehensive review on desiccant materials, regenerators, systems and improvement technologies," Applied Energy, Elsevier, vol. 308(C).
    10. Yinglin, Li & Xiaosong, Zhang & Laizai, Tan & Zhongbin, Zhang & Wei, Wu & Xueying, Xia, 2016. "Performance analysis of a novel liquid desiccant-vapor compression hybrid air-conditioning system," Energy, Elsevier, vol. 109(C), pages 180-189.
    11. Liu, Lin & Cheng, Qing, 2020. "Mass transfer characteristic research on electrodialysis for desalination and regeneration of solution: A comprehensive review," Renewable and Sustainable Energy Reviews, Elsevier, vol. 134(C).
    12. Yunlong Ma & Suvash C. Saha & Wendy Miller & Lisa Guan, 2017. "Parametric Analysis of Design Parameter Effects on the Performance of a Solar Desiccant Evaporative Cooling System in Brisbane, Australia," Energies, MDPI, vol. 10(7), pages 1-22, June.
    13. Kojok, Farah & Fardoun, Farouk & Younes, Rafic & Outbib, Rachid, 2016. "Hybrid cooling systems: A review and an optimized selection scheme," Renewable and Sustainable Energy Reviews, Elsevier, vol. 65(C), pages 57-80.
    14. Bigham, Sajjad & Yu, Dazhi & Chugh, Devesh & Moghaddam, Saeed, 2014. "Moving beyond the limits of mass transport in liquid absorbent microfilms through the implementation of surface-induced vortices," Energy, Elsevier, vol. 65(C), pages 621-630.
    15. Storle, Devin & Abdel-Salam, Mohamed R.H. & Simonson, Carey J., 2019. "Energy performance comparison of a 3-fluid and 2-fluid liquid desiccant membrane air-conditioning systems in an office building," Energy, Elsevier, vol. 176(C), pages 437-456.
    16. Shukla, D.L. & Modi, K.V., 2022. "Influence of distinct input parameters on performance indices of dehumidifier, regenerator and on liquid desiccant-operated evaporative cooling system – A critical review," Renewable and Sustainable Energy Reviews, Elsevier, vol. 168(C).
    17. Elsarrag, Esam & Igobo, Opubo N. & Alhorr, Yousef & Davies, Philip A., 2016. "Solar pond powered liquid desiccant evaporative cooling," Renewable and Sustainable Energy Reviews, Elsevier, vol. 58(C), pages 124-140.
    18. Pasqualin, P. & Lefers, R. & Mahmoud, S. & Davies, P.A., 2022. "Comparative review of membrane-based desalination technologies for energy-efficient regeneration in liquid desiccant air conditioning of greenhouses," Renewable and Sustainable Energy Reviews, Elsevier, vol. 154(C).
    19. Abdullah Abdulhameed Bagasi & John Kaiser Calautit & Abdullah Saeed Karban, 2021. "Evaluation of the Integration of the Traditional Architectural Element Mashrabiya into the Ventilation Strategy for Buildings in Hot Climates," Energies, MDPI, vol. 14(3), pages 1-31, January.
    20. Shafiqur Rehman & Muhammad M. Rafique & Luai M. Alhems & Md. Mahbub Alam, 2020. "Development and Implementation of Solar Assisted Desiccant Cooling Technology in Developing Countries: A Case of Saudi Arabia," Energies, MDPI, vol. 13(3), pages 1-22, January.

    Corrections

    All material on this site has been provided by the respective publishers and authors. You can help correct errors and omissions. When requesting a correction, please mention this item's handle: RePEc:gam:jeners:v:9:y:2016:i:4:p:305-:d:68693. See general information about how to correct material in RePEc.

    If you have authored this item and are not yet registered with RePEc, we encourage you to do it here. This allows to link your profile to this item. It also allows you to accept potential citations to this item that we are uncertain about.

    If CitEc recognized a bibliographic reference but did not link an item in RePEc to it, you can help with this form .

    If you know of missing items citing this one, you can help us creating those links by adding the relevant references in the same way as above, for each refering item. If you are a registered author of this item, you may also want to check the "citations" tab in your RePEc Author Service profile, as there may be some citations waiting for confirmation.

    For technical questions regarding this item, or to correct its authors, title, abstract, bibliographic or download information, contact: MDPI Indexing Manager (email available below). General contact details of provider: https://www.mdpi.com .

    Please note that corrections may take a couple of weeks to filter through the various RePEc services.

    IDEAS is a RePEc service. RePEc uses bibliographic data supplied by the respective publishers.