IDEAS home Printed from https://ideas.repec.org/a/eee/energy/v80y2015icp556-566.html
   My bibliography  Save this article

Performance of two-stage rotary desiccant cooling system with different regeneration temperatures

Author

Listed:
  • Ge, T.S.
  • Dai, Y.J.
  • Wang, R.Z.
  • Li, Y.

Abstract

Increasing attention is being given to energy-saving air conditioning technology in recent years. Using natural refrigerant and driven by low grade thermal energy, rotary desiccant cooling system has become a sound alternative solution to conventional vapor compression system. Although one-stage ventilation rotary desiccant cooling system is still the main stream, TSDC (two-stage rotary desiccant cooling) system recently emerges as the latest development, which can be driven by lower regeneration temperature (50–90 °C) compared with one-stage system. In this paper, performance of TSDC with different regeneration temperatures in two stages is analyzed. First integrated mathematical model of TSDC system is established by combing models of different components. Cooling power and COPth (thermal coefficient of performance) are utilized as performance indicators. Then system performance with respect to different combinations of two regeneration temperatures are simulated and discussed, while optimization investigation is also conducted to obtain maximum COPth with same cooling power. Under the simulation condition, results show that cooling power of the system increases with the increase of regeneration temperatures, however, COPth decreases. Also, when the first stage operates in higher regeneration temperature, TSDC system can obtain better performance reflecting in both cooling power and in COPth. Moreover, with the same cooling power provided, COPth of TSDC system obtains a minimum value when temperatures of the two stages approach.

Suggested Citation

  • Ge, T.S. & Dai, Y.J. & Wang, R.Z. & Li, Y., 2015. "Performance of two-stage rotary desiccant cooling system with different regeneration temperatures," Energy, Elsevier, vol. 80(C), pages 556-566.
  • Handle: RePEc:eee:energy:v:80:y:2015:i:c:p:556-566
    DOI: 10.1016/j.energy.2014.12.010
    as

    Download full text from publisher

    File URL: http://www.sciencedirect.com/science/article/pii/S0360544214013681
    Download Restriction: Full text for ScienceDirect subscribers only

    File URL: https://libkey.io/10.1016/j.energy.2014.12.010?utm_source=ideas
    LibKey link: if access is restricted and if your library uses this service, LibKey will redirect you to where you can use your library subscription to access this item
    ---><---

    As the access to this document is restricted, you may want to search for a different version of it.

    References listed on IDEAS

    as
    1. Ge, T.S. & Dai, Y.J. & Wang, R.Z. & Li, Y., 2008. "Experimental investigation on a one-rotor two-stage rotary desiccant cooling system," Energy, Elsevier, vol. 33(12), pages 1807-1815.
    2. Ge, T.S. & Li, Y. & Wang, R.Z. & Dai, Y.J., 2008. "A review of the mathematical models for predicting rotary desiccant wheel," Renewable and Sustainable Energy Reviews, Elsevier, vol. 12(6), pages 1485-1528, August.
    3. Baniyounes, Ali M. & Liu, Gang & Rasul, M.G. & Khan, M.M.K., 2012. "Analysis of solar desiccant cooling system for an institutional building in subtropical Queensland, Australia," Renewable and Sustainable Energy Reviews, Elsevier, vol. 16(8), pages 6423-6431.
    4. Khalid, A. & Mahmood, M. & Asif, M. & Muneer, T., 2009. "Solar assisted, pre-cooled hybrid desiccant cooling system for Pakistan," Renewable Energy, Elsevier, vol. 34(1), pages 151-157.
    Full references (including those not matched with items on IDEAS)

    Citations

    Citations are extracted by the CitEc Project, subscribe to its RSS feed for this item.
    as


    Cited by:

    1. Chen, Chih-Hao & Hsu, Chien-Yeh & Chen, Chih-Chieh & Chiang, Yuan-Ching & Chen, Sih-Li, 2016. "Silica gel/polymer composite desiccant wheel combined with heat pump for air-conditioning systems," Energy, Elsevier, vol. 94(C), pages 87-99.
    2. Gao, D.C. & Sun, Y.J. & Ma, Z. & Ren, H., 2021. "A review on integration and design of desiccant air-conditioning systems for overall performance improvements," Renewable and Sustainable Energy Reviews, Elsevier, vol. 141(C).
    3. Cui, X. & Islam, M.R. & Mohan, B. & Chua, K.J., 2016. "Theoretical analysis of a liquid desiccant based indirect evaporative cooling system," Energy, Elsevier, vol. 95(C), pages 303-312.
    4. Cui, X. & Islam, M.R. & Chua, K.J., 2019. "Experimental study and energy saving potential analysis of a hybrid air treatment cooling system in tropical climates," Energy, Elsevier, vol. 172(C), pages 1016-1026.
    5. Gado, Mohamed G. & Ookawara, Shinichi & Nada, Sameh & El-Sharkawy, Ibrahim I., 2021. "Hybrid sorption-vapor compression cooling systems: A comprehensive overview," Renewable and Sustainable Energy Reviews, Elsevier, vol. 143(C).

    Most related items

    These are the items that most often cite the same works as this one and are cited by the same works as this one.
    1. Ge, T.S. & Dai, Y.J. & Wang, R.Z., 2014. "Review on solar powered rotary desiccant wheel cooling system," Renewable and Sustainable Energy Reviews, Elsevier, vol. 39(C), pages 476-497.
    2. Shamim, Jubair A. & Hsu, Wei-Lun & Paul, Soumyadeep & Yu, Lili & Daiguji, Hirofumi, 2021. "A review of solid desiccant dehumidifiers: Current status and near-term development goals in the context of net zero energy buildings," Renewable and Sustainable Energy Reviews, Elsevier, vol. 137(C).
    3. Rambhad, Kishor S. & Walke, Pramod V. & Tidke, D.J., 2016. "Solid desiccant dehumidification and regeneration methods—A review," Renewable and Sustainable Energy Reviews, Elsevier, vol. 59(C), pages 73-83.
    4. Jani, D.B. & Mishra, Manish & Sahoo, P.K., 2016. "Solid desiccant air conditioning – A state of the art review," Renewable and Sustainable Energy Reviews, Elsevier, vol. 60(C), pages 1451-1469.
    5. La, D. & Dai, Y.J. & Li, Y. & Wang, R.Z. & Ge, T.S., 2010. "Technical development of rotary desiccant dehumidification and air conditioning: A review," Renewable and Sustainable Energy Reviews, Elsevier, vol. 14(1), pages 130-147, January.
    6. Jani, D.B. & Mishra, Manish & Sahoo, P.K., 2017. "Application of artificial neural network for predicting performance of solid desiccant cooling systems – A review," Renewable and Sustainable Energy Reviews, Elsevier, vol. 80(C), pages 352-366.
    7. Sphaier, L.A. & Nóbrega, C.E.L., 2012. "Parametric analysis of components effectiveness on desiccant cooling system performance," Energy, Elsevier, vol. 38(1), pages 157-166.
    8. Kojok, Farah & Fardoun, Farouk & Younes, Rafic & Outbib, Rachid, 2016. "Hybrid cooling systems: A review and an optimized selection scheme," Renewable and Sustainable Energy Reviews, Elsevier, vol. 65(C), pages 57-80.
    9. Amit Kumar & Avadhesh Yadav, 2017. "Experimental investigation of solar-powered desiccant cooling system by using composite desiccant “CaCl2/jute”," Environment, Development and Sustainability: A Multidisciplinary Approach to the Theory and Practice of Sustainable Development, Springer, vol. 19(4), pages 1279-1292, August.
    10. Panaras, G. & Mathioulakis, E. & Belessiotis, V. & Kyriakis, N., 2010. "Theoretical and experimental investigation of the performance of a desiccant air-conditioning system," Renewable Energy, Elsevier, vol. 35(7), pages 1368-1375.
    11. Hua, L.J. & Ge, T.S. & Wang, R.Z., 2019. "Extremely high efficient heat pump with desiccant coated evaporator and condenser," Energy, Elsevier, vol. 170(C), pages 569-579.
    12. Feng, Y.H. & Dai, Y.J. & Wang, R.Z. & Ge, T.S., 2022. "Insights into desiccant-based internally-cooled dehumidification using porous sorbents: From a modeling viewpoint," Applied Energy, Elsevier, vol. 311(C).
    13. Lanbo Lai & Xiaolin Wang & Gholamreza Kefayati & Eric Hu, 2021. "Evaporative Cooling Integrated with Solid Desiccant Systems: A Review," Energies, MDPI, vol. 14(18), pages 1-23, September.
    14. Lo Basso, Gianluigi & de Santoli, Livio & Paiolo, Romano & Losi, Claudio, 2021. "The potential role of trans-critical CO2 heat pumps within a solar cooling system for building services: The hybridised system energy analysis by a dynamic simulation model," Renewable Energy, Elsevier, vol. 164(C), pages 472-490.
    15. De Antonellis, Stefano & Joppolo, Cesare Maria & Molinaroli, Luca & Pasini, Alberto, 2012. "Simulation and energy efficiency analysis of desiccant wheel systems for drying processes," Energy, Elsevier, vol. 37(1), pages 336-345.
    16. Wang, Nan & Zhang, Jiangfeng & Xia, Xiaohua, 2013. "Desiccant wheel thermal performance modeling for indoor humidity optimal control," Applied Energy, Elsevier, vol. 112(C), pages 999-1005.
    17. B. Kiran Naik & Mullapudi Joshi & Palanisamy Muthukumar & Muhammad Sultan & Takahiko Miyazaki & Redmond R. Shamshiri & Hadeed Ashraf, 2020. "Investigating Solid and Liquid Desiccant Dehumidification Options for Room Air-Conditioning and Drying Applications," Sustainability, MDPI, vol. 12(24), pages 1-22, December.
    18. Liu, Xiao-Hua & Zhang, Tao & Zheng, Yu-Wei & Tu, Rang, 2016. "Performance investigation and exergy analysis of two-stage desiccant wheel systems," Renewable Energy, Elsevier, vol. 86(C), pages 877-888.
    19. Ruivo, Celestino R. & Goldsworthy, Mark & Intini, Manuel, 2014. "Interpolation methods to predict the influence of inlet airflow states on desiccant wheel performance at low regeneration temperature," Energy, Elsevier, vol. 68(C), pages 765-772.
    20. Panaras, G. & Mathioulakis, E. & Belessiotis, V., 2011. "Solid desiccant air-conditioning systems – Design parameters," Energy, Elsevier, vol. 36(5), pages 2399-2406.

    Corrections

    All material on this site has been provided by the respective publishers and authors. You can help correct errors and omissions. When requesting a correction, please mention this item's handle: RePEc:eee:energy:v:80:y:2015:i:c:p:556-566. See general information about how to correct material in RePEc.

    If you have authored this item and are not yet registered with RePEc, we encourage you to do it here. This allows to link your profile to this item. It also allows you to accept potential citations to this item that we are uncertain about.

    If CitEc recognized a bibliographic reference but did not link an item in RePEc to it, you can help with this form .

    If you know of missing items citing this one, you can help us creating those links by adding the relevant references in the same way as above, for each refering item. If you are a registered author of this item, you may also want to check the "citations" tab in your RePEc Author Service profile, as there may be some citations waiting for confirmation.

    For technical questions regarding this item, or to correct its authors, title, abstract, bibliographic or download information, contact: Catherine Liu (email available below). General contact details of provider: http://www.journals.elsevier.com/energy .

    Please note that corrections may take a couple of weeks to filter through the various RePEc services.

    IDEAS is a RePEc service. RePEc uses bibliographic data supplied by the respective publishers.