IDEAS home Printed from https://ideas.repec.org/a/eee/energy/v52y2013icp245-257.html
   My bibliography  Save this article

Cooling performance of a 100% outdoor air system integrated with indirect and direct evaporative coolers

Author

Listed:
  • Kim, Min-Hwi
  • Jeong, Jae-Weon

Abstract

The object of this study was to evaluate the energy performance of an indirect and direct evaporative cooler assisted 100% outdoor air system (IDECOAS), of which a pilot unit was installed in a campus building, during its actual operation in cooling and intermediate seasons. A conventional variable air volume (VAV) system was also installed for comparison with the proposed system. The IDECOAS operated in two operation modes (i.e., single-stage and two-stage operation) depending on the seasonal conditions (i.e., intermediate season and cooling season). In addition, the effectiveness of the indirect evaporative cooler (IEC) and the direct evaporative cooler (DEC) were monitored by measuring the variation of air temperature and relative humidity at each measurement location. The fan and cooling coil energy consumption were also measured by installing watt meters on each device. It was concluded that the IDECOAS operating in the two-stage mode in the intermediate season shows a 51% energy saving over the conventional VAV system. However, the proposed system may consume 36% more operating energy than the conventional VAV system during the cooling season. This may be caused by limited cooling performance of the IEC in hot and humid climate.

Suggested Citation

  • Kim, Min-Hwi & Jeong, Jae-Weon, 2013. "Cooling performance of a 100% outdoor air system integrated with indirect and direct evaporative coolers," Energy, Elsevier, vol. 52(C), pages 245-257.
  • Handle: RePEc:eee:energy:v:52:y:2013:i:c:p:245-257
    DOI: 10.1016/j.energy.2013.02.008
    as

    Download full text from publisher

    File URL: http://www.sciencedirect.com/science/article/pii/S0360544213001126
    Download Restriction: Full text for ScienceDirect subscribers only

    File URL: https://libkey.io/10.1016/j.energy.2013.02.008?utm_source=ideas
    LibKey link: if access is restricted and if your library uses this service, LibKey will redirect you to where you can use your library subscription to access this item
    ---><---

    As the access to this document is restricted, you may want to search for a different version of it.

    References listed on IDEAS

    as
    1. Farmahini-Farahani, Moien & Delfani, Shahram & Esmaeelian, Jafar, 2012. "Exergy analysis of evaporative cooling to select the optimum system in diverse climates," Energy, Elsevier, vol. 40(1), pages 250-257.
    2. Zhan, Changhong & Duan, Zhiyin & Zhao, Xudong & Smith, Stefan & Jin, Hong & Riffat, Saffa, 2011. "Comparative study of the performance of the M-cycle counter-flow and cross-flow heat exchangers for indirect evaporative cooling – Paving the path toward sustainable cooling of buildings," Energy, Elsevier, vol. 36(12), pages 6790-6805.
    3. Maheshwari, G. P. & Al-Ragom, F. & Suri, R. K., 2001. "Energy-saving potential of an indirect evaporative cooler," Applied Energy, Elsevier, vol. 69(1), pages 69-76, May.
    Full references (including those not matched with items on IDEAS)

    Citations

    Citations are extracted by the CitEc Project, subscribe to its RSS feed for this item.
    as


    Cited by:

    1. Campaniço, Hugo & Hollmuller, Pierre & Soares, Pedro M.M., 2014. "Assessing energy savings in cooling demand of buildings using passive cooling systems based on ventilation," Applied Energy, Elsevier, vol. 134(C), pages 426-438.
    2. Krzysztof Rajski & Jan Danielewicz & Ewa Brychcy, 2020. "Performance Evaluation of a Gravity-Assisted Heat Pipe-Based Indirect Evaporative Cooler," Energies, MDPI, vol. 13(1), pages 1-20, January.
    3. Islam, M.R. & Jahangeer, K.A. & Chua, K.J., 2015. "Experimental and numerical study of an evaporatively-cooled condenser of air-conditioning systems," Energy, Elsevier, vol. 87(C), pages 390-399.
    4. Shazia Noor & Hadeed Ashraf & Muhammad Sultan & Zahid Mahmood Khan, 2020. "Evaporative Cooling Options for Building Air-Conditioning: A Comprehensive Study for Climatic Conditions of Multan (Pakistan)," Energies, MDPI, vol. 13(12), pages 1-23, June.
    5. Shiying Li & Jae-Weon Jeong, 2018. "Energy Performance of Liquid Desiccant and Evaporative Cooling-Assisted 100% Outdoor Air Systems under Various Climatic Conditions," Energies, MDPI, vol. 11(6), pages 1-22, May.
    6. Yang, Siyu & Yang, Qingchun & Qian, Yu, 2013. "A composite efficiency metrics for evaluation of resource and energy utilization," Energy, Elsevier, vol. 61(C), pages 455-462.
    7. Bo Shen & Joshua New & Moonis Ally, 2019. "Energy and Economics Analyses of Condenser Evaporative Precooling for Various Climates, Buildings and Refrigerants," Energies, MDPI, vol. 12(11), pages 1-17, May.
    8. Campaniço, Hugo & Soares, Pedro M.M. & Hollmuller, Pierre & Cardoso, Rita M., 2016. "Climatic cooling potential and building cooling demand savings: High resolution spatiotemporal analysis of direct ventilation and evaporative cooling for the Iberian Peninsula," Renewable Energy, Elsevier, vol. 85(C), pages 766-776.
    9. Chen, Yi & Yan, Huaxia & Yang, Hongxing, 2018. "Comparative study of on-off control and novel high-low control of regenerative indirect evaporative cooler (RIEC)," Applied Energy, Elsevier, vol. 225(C), pages 233-243.
    10. Hadeed Ashraf & Muhammad Sultan & Uzair Sajjad & Muhammad Wakil Shahzad & Muhammad Farooq & Sobhy M. Ibrahim & Muhammad Usman Khan & Muhammad Ahmad Jamil, 2022. "Potential Investigation of Membrane Energy Recovery Ventilators for the Management of Building Air-Conditioning Loads," Energies, MDPI, vol. 15(6), pages 1-23, March.
    11. Ghiaus, Christian, 2014. "Linear algebra solution to psychometric analysis of air-conditioning systems," Energy, Elsevier, vol. 74(C), pages 555-566.
    12. Wonjun Kim & Hye-Won Dong & Junseok Park & Minki Sung & Jae-Weon Jeong, 2018. "Impact of an Ultraviolet Reactor on the Improvement of Air Quality Leaving a Direct Evaporative Cooler," Sustainability, MDPI, vol. 10(4), pages 1-16, April.

    Most related items

    These are the items that most often cite the same works as this one and are cited by the same works as this one.
    1. Duan, Zhiyin & Zhan, Changhong & Zhang, Xingxing & Mustafa, Mahmud & Zhao, Xudong & Alimohammadisagvand, Behrang & Hasan, Ala, 2012. "Indirect evaporative cooling: Past, present and future potentials," Renewable and Sustainable Energy Reviews, Elsevier, vol. 16(9), pages 6823-6850.
    2. Muhammad Aleem & Ghulam Hussain & Muhammad Sultan & Takahiko Miyazaki & Muhammad H. Mahmood & Muhammad I. Sabir & Abdul Nasir & Faizan Shabir & Zahid M. Khan, 2020. "Experimental Investigation of Desiccant Dehumidification Cooling System for Climatic Conditions of Multan (Pakistan)," Energies, MDPI, vol. 13(21), pages 1-23, October.
    3. Muhammad Kashif & Hassan Niaz & Muhammad Sultan & Takahiko Miyazaki & Yongqiang Feng & Muhammad Usman & Muhammad W. Shahzad & Yasir Niaz & Muhammad M. Waqas & Imran Ali, 2020. "Study on Desiccant and Evaporative Cooling Systems for Livestock Thermal Comfort: Theory and Experiments," Energies, MDPI, vol. 13(11), pages 1-18, May.
    4. Zeynab Emdadi & Nilofar Asim & Mohd Ambar Yarmo & Roslinda Shamsudin & Masita Mohammad & Kamaruzaman Sopian, 2016. "Green Material Prospects for Passive Evaporative Cooling Systems: Geopolymers," Energies, MDPI, vol. 9(8), pages 1-19, July.
    5. Xu, Peng & Ma, Xiaoli & Zhao, Xudong & Fancey, Kevin, 2017. "Experimental investigation of a super performance dew point air cooler," Applied Energy, Elsevier, vol. 203(C), pages 761-777.
    6. Cui, Yuanlong & Zhu, Jie & Zoras, Stamatis & Liu, Lin, 2021. "Review of the recent advances in dew point evaporative cooling technology: 3E (energy, economic and environmental) assessments," Renewable and Sustainable Energy Reviews, Elsevier, vol. 148(C).
    7. Cui, X. & Chua, K.J. & Yang, W.M., 2014. "Numerical simulation of a novel energy-efficient dew-point evaporative air cooler," Applied Energy, Elsevier, vol. 136(C), pages 979-988.
    8. Zhou, Yuanyuan & Zhang, Tao & Wang, Fang & Yu, Yanshun, 2018. "Performance analysis of a novel thermoelectric assisted indirect evaporative cooling system," Energy, Elsevier, vol. 162(C), pages 299-308.
    9. Jradi, M. & Riffat, S., 2014. "Experimental and numerical investigation of a dew-point cooling system for thermal comfort in buildings," Applied Energy, Elsevier, vol. 132(C), pages 524-535.
    10. Kashyap, Sarvesh & Sarkar, Jahar & Kumar, Amitesh, 2021. "Performance enhancement of regenerative evaporative cooler by surface alterations and using ternary hybrid nanofluids," Energy, Elsevier, vol. 225(C).
    11. Sadighi Dizaji, Hamed & Hu, Eric Jing & Chen, Lei & Pourhedayat, Samira, 2020. "Analytical/experimental sensitivity study of key design and operational parameters of perforated Maisotsenko cooler based on novel wet-surface theory," Applied Energy, Elsevier, vol. 262(C).
    12. Cui, X. & Islam, M.R. & Mohan, B. & Chua, K.J., 2016. "Theoretical analysis of a liquid desiccant based indirect evaporative cooling system," Energy, Elsevier, vol. 95(C), pages 303-312.
    13. Ham, Sang-Woo & Jeong, Jae-Weon, 2016. "DPHX (dew point evaporative heat exchanger): System design and performance analysis," Energy, Elsevier, vol. 101(C), pages 132-145.
    14. Zhan, Changhong & Duan, Zhiyin & Zhao, Xudong & Smith, Stefan & Jin, Hong & Riffat, Saffa, 2011. "Comparative study of the performance of the M-cycle counter-flow and cross-flow heat exchangers for indirect evaporative cooling – Paving the path toward sustainable cooling of buildings," Energy, Elsevier, vol. 36(12), pages 6790-6805.
    15. Mahmood, Muhammad H. & Sultan, Muhammad & Miyazaki, Takahiko & Koyama, Shigeru & Maisotsenko, Valeriy S., 2016. "Overview of the Maisotsenko cycle – A way towards dew point evaporative cooling," Renewable and Sustainable Energy Reviews, Elsevier, vol. 66(C), pages 537-555.
    16. Hafiz M. Asfahan & Uzair Sajjad & Muhammad Sultan & Imtiyaz Hussain & Khalid Hamid & Mubasher Ali & Chi-Chuan Wang & Redmond R. Shamshiri & Muhammad Usman Khan, 2021. "Artificial Intelligence for the Prediction of the Thermal Performance of Evaporative Cooling Systems," Energies, MDPI, vol. 14(13), pages 1-20, July.
    17. Nada, S.A. & Elattar, H.F. & Mahmoud, M.A. & Fouda, A., 2020. "Performance enhancement and heat and mass transfer characteristics of direct evaporative building free cooling using corrugated cellulose papers," Energy, Elsevier, vol. 211(C).
    18. Mohammad, Abdulrahman Th. & Bin Mat, Sohif & Sulaiman, M.Y. & Sopian, K. & Al-abidi, Abduljalil A., 2013. "Survey of hybrid liquid desiccant air conditioning systems," Renewable and Sustainable Energy Reviews, Elsevier, vol. 20(C), pages 186-200.
    19. Akhlaghi, Yousef Golizadeh & Ma, Xiaoli & Zhao, Xudong & Shittu, Samson & Li, Junming, 2019. "A statistical model for dew point air cooler based on the multiple polynomial regression approach," Energy, Elsevier, vol. 181(C), pages 868-881.
    20. Xiao, Xin & Liu, Jinjin, 2024. "A state-of-art review of dew point evaporative cooling technology and integrated applications," Renewable and Sustainable Energy Reviews, Elsevier, vol. 191(C).

    Corrections

    All material on this site has been provided by the respective publishers and authors. You can help correct errors and omissions. When requesting a correction, please mention this item's handle: RePEc:eee:energy:v:52:y:2013:i:c:p:245-257. See general information about how to correct material in RePEc.

    If you have authored this item and are not yet registered with RePEc, we encourage you to do it here. This allows to link your profile to this item. It also allows you to accept potential citations to this item that we are uncertain about.

    If CitEc recognized a bibliographic reference but did not link an item in RePEc to it, you can help with this form .

    If you know of missing items citing this one, you can help us creating those links by adding the relevant references in the same way as above, for each refering item. If you are a registered author of this item, you may also want to check the "citations" tab in your RePEc Author Service profile, as there may be some citations waiting for confirmation.

    For technical questions regarding this item, or to correct its authors, title, abstract, bibliographic or download information, contact: Catherine Liu (email available below). General contact details of provider: http://www.journals.elsevier.com/energy .

    Please note that corrections may take a couple of weeks to filter through the various RePEc services.

    IDEAS is a RePEc service. RePEc uses bibliographic data supplied by the respective publishers.