Experimental study on the thermal comfort in the room equipped with a radiant floor heating system exposed to direct solar radiation
Author
Abstract
Suggested Citation
DOI: 10.1016/j.energy.2021.120800
Download full text from publisher
As the access to this document is restricted, you may want to search for a different version of it.
References listed on IDEAS
- Guo, Hongshan & Aviv, Dorit & Loyola, Mauricio & Teitelbaum, Eric & Houchois, Nicholas & Meggers, Forrest, 2020. "On the understanding of the mean radiant temperature within both the indoor and outdoor environment, a critical review," Renewable and Sustainable Energy Reviews, Elsevier, vol. 117(C).
- Gwerder, M. & Tödtli, J. & Lehmann, B. & Dorer, V. & Güntensperger, W. & Renggli, F., 2009. "Control of thermally activated building systems (TABS) in intermittent operation with pulse width modulation," Applied Energy, Elsevier, vol. 86(9), pages 1606-1616, September.
Citations
Citations are extracted by the CitEc Project, subscribe to its RSS feed for this item.
Cited by:
- Yang, Zixu & Sun, Hongli & Wang, Baolong & Xiao, Hansong & Dong, Xian & Shi, Wenxing & Lin, Borong, 2022. "Experimental investigation on indoor environment and energy performance of convective terminals," Energy, Elsevier, vol. 251(C).
- Xie, Xing & Xia, Fei & Zhao, Yu-qian & Xu, Bin & Wang, Yang-liang & Pei, Gang, 2022. "Parametric study on the effect of radiant heating system on indoor thermal comfort with/without external thermal disturbance," Energy, Elsevier, vol. 249(C).
Most related items
These are the items that most often cite the same works as this one and are cited by the same works as this one.- Ma, Peizheng & Wang, Lin-Shu & Guo, Nianhua, 2015. "Maximum window-to-wall ratio of a thermally autonomous building as a function of envelope U-value and ambient temperature amplitude," Applied Energy, Elsevier, vol. 146(C), pages 84-91.
- Lehmann, B. & Dorer, V. & Gwerder, M. & Renggli, F. & Tödtli, J., 2011. "Thermally activated building systems (TABS): Energy efficiency as a function of control strategy, hydronic circuit topology and (cold) generation system," Applied Energy, Elsevier, vol. 88(1), pages 180-191, January.
- Georgios D. Kontes & Georgios I. Giannakis & Víctor Sánchez & Pablo De Agustin-Camacho & Ander Romero-Amorrortu & Natalia Panagiotidou & Dimitrios V. Rovas & Simone Steiger & Christopher Mutschler & G, 2018. "Simulation-Based Evaluation and Optimization of Control Strategies in Buildings," Energies, MDPI, vol. 11(12), pages 1-23, December.
- Xuemin Sui & Huajiang Wang & Ming Qu & Huitao Liu, 2020. "Thermal Response Characteristics of Intermittently Cooled Room with Tube-Embedded Cooling Slab and Optimization of Intermittent Control," Energies, MDPI, vol. 13(7), pages 1-28, March.
- Piotr Michalak, 2021. "Selected Aspects of Indoor Climate in a Passive Office Building with a Thermally Activated Building System: A Case Study from Poland," Energies, MDPI, vol. 14(4), pages 1-22, February.
- Schmelas, Martin & Feldmann, Thomas & Bollin, Elmar, 2017. "Savings through the use of adaptive predictive control of thermo-active building systems (TABS): A case study," Applied Energy, Elsevier, vol. 199(C), pages 294-309.
- He, Xianya & Huang, Jingzhi & Liu, Zekun & Lin, Jian & Jing, Rui & Zhao, Yingru, 2023. "Topology optimization of thermally activated building system in high-rise building," Energy, Elsevier, vol. 284(C).
- Wang, Nan & Ghaeili, Neda & Wang, Julian & Feng, Yanxiao & Zhang, Enhe & Chen, Chenshun, 2023. "Using architectural glazing systems to harness solar thermal potential for energy savings and indoor comfort," Renewable Energy, Elsevier, vol. 219(P1).
- Jia, Hongyuan & Pang, Xiufeng & Haves, Philip, 2018. "Experimentally-determined characteristics of radiant systems for office buildings," Applied Energy, Elsevier, vol. 221(C), pages 41-54.
- Ma, Peizheng & Wang, Lin-Shu & Guo, Nianhua, 2015. "Energy storage and heat extraction – From thermally activated building systems (TABS) to thermally homeostatic buildings," Renewable and Sustainable Energy Reviews, Elsevier, vol. 45(C), pages 677-685.
- Lim, Jae-Han & Song, Jin-Hee & Song, Seung-Yeong, 2014. "Development of operational guidelines for thermally activated building system according to heating and cooling load characteristics," Applied Energy, Elsevier, vol. 126(C), pages 123-135.
- Ma, Peizheng & Wang, Lin-Shu & Guo, Nianhua, 2013. "Modeling of TABS-based thermally manageable buildings in Simulink," Applied Energy, Elsevier, vol. 104(C), pages 791-800.
- Chen, Zhaoxin & Li, Jiaxuan & Tang, Guoqiang & Zhang, Jiahao & Zhang, Donghai & Gao, Penghui, 2024. "High-efficiency heating and cooling technology with embedded pipes in buildings and underground structures: A review," Renewable and Sustainable Energy Reviews, Elsevier, vol. 192(C).
- Romaní, Joaquim & Pérez, Gabriel & de Gracia, Alvaro, 2017. "Experimental evaluation of a heating radiant wall coupled to a ground source heat pump," Renewable Energy, Elsevier, vol. 105(C), pages 520-529.
- Ma, Peizheng & Wang, Lin-Shu & Guo, Nianhua, 2014. "Modeling of hydronic radiant cooling of a thermally homeostatic building using a parametric cooling tower," Applied Energy, Elsevier, vol. 127(C), pages 172-181.
- Xuexiu Zhao & Yanwen Luo & Jiang He, 2020. "Analysis of the Thermal Environment in Pedestrian Space Using 3D Thermal Imaging," Energies, MDPI, vol. 13(14), pages 1-15, July.
- Lydon, G.P. & Hofer, J. & Svetozarevic, B. & Nagy, Z. & Schlueter, A., 2017. "Coupling energy systems with lightweight structures for a net plus energy building," Applied Energy, Elsevier, vol. 189(C), pages 310-326.
- Romaní, Joaquim & Belusko, Martin & Alemu, Alemu & Cabeza, Luisa F. & de Gracia, Alvaro & Bruno, Frank, 2018. "Control concepts of a radiant wall working as thermal energy storage for peak load shifting of a heat pump coupled to a PV array," Renewable Energy, Elsevier, vol. 118(C), pages 489-501.
- Krzaczek, M. & Florczuk, J. & Tejchman, J., 2019. "Improved energy management technique in pipe-embedded wall heating/cooling system in residential buildings," Applied Energy, Elsevier, vol. 254(C).
- Woong June Chung & Sang Hoon Park & Myoung Souk Yeo & Kwang Woo Kim, 2017. "Control of Thermally Activated Building System Considering Zone Load Characteristics," Sustainability, MDPI, vol. 9(4), pages 1-14, April.
More about this item
Keywords
Floor heating system; Sun patch; Thermal comfort; Overheating; Experiments;All these keywords.
Statistics
Access and download statisticsCorrections
All material on this site has been provided by the respective publishers and authors. You can help correct errors and omissions. When requesting a correction, please mention this item's handle: RePEc:eee:energy:v:230:y:2021:i:c:s0360544221010483. See general information about how to correct material in RePEc.
If you have authored this item and are not yet registered with RePEc, we encourage you to do it here. This allows to link your profile to this item. It also allows you to accept potential citations to this item that we are uncertain about.
If CitEc recognized a bibliographic reference but did not link an item in RePEc to it, you can help with this form .
If you know of missing items citing this one, you can help us creating those links by adding the relevant references in the same way as above, for each refering item. If you are a registered author of this item, you may also want to check the "citations" tab in your RePEc Author Service profile, as there may be some citations waiting for confirmation.
For technical questions regarding this item, or to correct its authors, title, abstract, bibliographic or download information, contact: Catherine Liu (email available below). General contact details of provider: http://www.journals.elsevier.com/energy .
Please note that corrections may take a couple of weeks to filter through the various RePEc services.