IDEAS home Printed from https://ideas.repec.org/a/gam/jsusta/v16y2024i8p3107-d1372330.html
   My bibliography  Save this article

Research Optimizing Building Ventilation Performance through the Application of Trombe Walls in Regions with Hot Summers and Cold Winters: A Case Study in China

Author

Listed:
  • Zechao Sheng

    (Department of Landscape and Architecture, Zhejiang Agriculture and Forestry University, Hangzhou 311300, China
    These authors contributed equally to this work.)

  • Guoyi Zhang

    (Department of Landscape and Architecture, Zhejiang Agriculture and Forestry University, Hangzhou 311300, China
    These authors contributed equally to this work.)

  • Xiaojun Luo

    (China Construction Fifth Engineering Division Co., Ltd., Hangzhou 311300, China)

  • Chenle Ye

    (Department of Landscape and Architecture, Zhejiang Agriculture and Forestry University, Hangzhou 311300, China)

  • Jinhe Lin

    (Guangzhou Meiya Energy Storage Technology Company, Guangzhou 510000, China)

  • Zhonggou Chen

    (Department of Landscape and Architecture, Zhejiang Agriculture and Forestry University, Hangzhou 311300, China)

Abstract

The hot-summer and cold-winter climate zone spans a large latitude, where the passive means of retrofitting the Trombe wall (TW) can be utilized to effectively improve the indoor wind environment and thermal comfort. In this study, a public building in Wenzhou, China, was selected as the object, and CFD numerical simulations and the wind environment data in spring, summer, and fall were collected through field experimental measurements. Comparative analyses were carried out to explore the adaptive strategy and effectiveness of the application of the Trombe wall on the local wind environment and climate and to quantify the improvement effect of the application of the Trombe wall on the Indoor environment. The results showed that the application of the Trombe wall in spring and fall in hot-summer and cold-winter regions could obviously increase the average indoor wind speed and the wind speed at the building outlet by 0.2–0.8 m/s and 0.9–3.6 m/s, respectively. This further effectively prolongs the indoor thermal comfort hours in spring and fall, which is a relatively applicable season, while the ventilation performance in summer is poor compared to spring and fall seasons.

Suggested Citation

  • Zechao Sheng & Guoyi Zhang & Xiaojun Luo & Chenle Ye & Jinhe Lin & Zhonggou Chen, 2024. "Research Optimizing Building Ventilation Performance through the Application of Trombe Walls in Regions with Hot Summers and Cold Winters: A Case Study in China," Sustainability, MDPI, vol. 16(8), pages 1-23, April.
  • Handle: RePEc:gam:jsusta:v:16:y:2024:i:8:p:3107-:d:1372330
    as

    Download full text from publisher

    File URL: https://www.mdpi.com/2071-1050/16/8/3107/pdf
    Download Restriction: no

    File URL: https://www.mdpi.com/2071-1050/16/8/3107/
    Download Restriction: no
    ---><---

    References listed on IDEAS

    as
    1. Ma, Qingsong & Fukuda, Hiroatsu & Lee, Myonghyang & Kobatake, Takumi & Kuma, Yuko & Ozaki, Akihito, 2018. "Study on the utilization of heat in the mechanically ventilated Trombe wall in a house with a central air conditioning and air circulation system," Applied Energy, Elsevier, vol. 222(C), pages 861-871.
    2. Khedari, Joseph & Rachapradit, Ninnart & Hirunlabh, Jongjit, 2003. "Field study of performance of solar chimney with air-conditioned building," Energy, Elsevier, vol. 28(11), pages 1099-1114.
    3. Du, Li & Ping, Lin & Yongming, Chen, 2020. "Study and analysis of air flow characteristics in Trombe wall," Renewable Energy, Elsevier, vol. 162(C), pages 234-241.
    Full references (including those not matched with items on IDEAS)

    Most related items

    These are the items that most often cite the same works as this one and are cited by the same works as this one.
    1. Zhang, Haihua & Yang, Dong & Tam, Vivian W.Y. & Tao, Yao & Zhang, Guomin & Setunge, Sujeeva & Shi, Long, 2021. "A critical review of combined natural ventilation techniques in sustainable buildings," Renewable and Sustainable Energy Reviews, Elsevier, vol. 141(C).
    2. Duan, Xiaojian & Shen, Chao & Liu, Dingming & Wu, Yupeng, 2023. "The performance analysis of a photo/thermal catalytic Trombe wall with energy generation," Renewable Energy, Elsevier, vol. 218(C).
    3. Chi, Fang'ai & Xu, Liming & Peng, Changhai, 2020. "Integration of completely passive cooling and heating systems with daylighting function into courtyard building towards energy saving," Applied Energy, Elsevier, vol. 266(C).
    4. Lee, Haksung & Ozaki, Akihito, 2018. "Sensitivity analysis for optimization of renewable-energy-based air-circulation-type temperature-control system," Applied Energy, Elsevier, vol. 230(C), pages 317-329.
    5. Lech Lichołai & Aleksander Starakiewicz & Joanna Krasoń & Przemysław Miąsik, 2021. "The Influence of Glazing on the Functioning of a Trombe Wall Containing a Phase Change Material," Energies, MDPI, vol. 14(17), pages 1-19, August.
    6. Shi, Long, 2018. "Theoretical models for wall solar chimney under cooling and heating modes considering room configuration," Energy, Elsevier, vol. 165(PB), pages 925-938.
    7. Abdulmajeed Mohamad & Jan Taler & Paweł Ocłoń, 2019. "Trombe Wall Utilization for Cold and Hot Climate Conditions," Energies, MDPI, vol. 12(2), pages 1-18, January.
    8. Punyasompun, Sompop & Hirunlabh, Jongjit & Khedari, Joseph & Zeghmati, Belkacem, 2009. "Investigation on the application of solar chimney for multi-storey buildings," Renewable Energy, Elsevier, vol. 34(12), pages 2545-2561.
    9. Xamán, J. & Vargas-López, R. & Gijón-Rivera, M. & Zavala-Guillén, I. & Jiménez, M.J. & Arce, J., 2019. "Transient thermal analysis of a solar chimney for buildings with three different types of absorbing materials: Copper plate/PCM/concrete wall," Renewable Energy, Elsevier, vol. 136(C), pages 139-158.
    10. Wang, Lin & Zhou, Jinzhi & Bisengimana, Emmanuel & Ji, Yasheng & Zhong, Wei & Yuan, Yanping & Lu, Lin, 2023. "Numerical study on the thermal and electrical performance of a novel MCHP PV-Trombe wall system," Energy, Elsevier, vol. 269(C).
    11. Hong, Xiaoqiang & Leung, Michael K.H. & He, Wei, 2019. "Effective use of venetian blind in Trombe wall for solar space conditioning control," Applied Energy, Elsevier, vol. 250(C), pages 452-460.
    12. Chen, Yulu & Lee, Haksung & Ozaki, Akihito & Choi, Younhee & Arima, Yusuke, 2024. "Experimental and numerical investigation of integrating energy recovery ventilation into a thermodynamic-potential-based passive dehumidification system using renewable energy," Energy, Elsevier, vol. 289(C).
    13. Wang, Ye & Chen, Xueqin & Qi, Xiaobing & Zhou, Jie, 2024. "Numerical study on the effect of optimizing the Trombe wall structure with built-in fins on improving building energy efficiency in severe cold region," Renewable Energy, Elsevier, vol. 222(C).
    14. Arce, J. & Jiménez, M.J. & Guzmán, J.D. & Heras, M.R. & Alvarez, G. & Xamán, J., 2009. "Experimental study for natural ventilation on a solar chimney," Renewable Energy, Elsevier, vol. 34(12), pages 2928-2934.
    15. Aleksejs Prozuments & Anatolijs Borodinecs & Guna Bebre & Diana Bajare, 2023. "A Review on Trombe Wall Technology Feasibility and Applications," Sustainability, MDPI, vol. 15(5), pages 1-15, February.
    16. Yu, Bendong & Hou, Jingxin & He, Wei & Liu, Shanshan & Hu, Zhongting & Ji, Jie & Chen, Hongbing & Xu, Gang, 2018. "Study on a high-performance photocatalytic-Trombe wall system for space heating and air purification," Applied Energy, Elsevier, vol. 226(C), pages 365-380.
    17. Quesada, Guillermo & Rousse, Daniel & Dutil, Yvan & Badache, Messaoud & Hallé, Stéphane, 2012. "A comprehensive review of solar facades. Opaque solar facades," Renewable and Sustainable Energy Reviews, Elsevier, vol. 16(5), pages 2820-2832.
    18. Wang, Qingyuan & Zhang, Guomin & Wu, Qihong & Li, Wenyuan & Shi, Long, 2022. "A combined wall and roof solar chimney in one building," Energy, Elsevier, vol. 240(C).
    19. Yuewei Zhu & Tao Zhang & Qingsong Ma & Hiroatsu Fukuda, 2022. "Thermal Performance and Optimizing of Composite Trombe Wall with Temperature-Controlled DC Fan in Winter," Sustainability, MDPI, vol. 14(5), pages 1-15, March.
    20. Vargas-López, R. & Xamán, J. & Hernández-Pérez, I. & Arce, J. & Zavala-Guillén, I. & Jiménez, M.J. & Heras, M.R., 2019. "Mathematical models of solar chimneys with a phase change material for ventilation of buildings: A review using global energy balance," Energy, Elsevier, vol. 170(C), pages 683-708.

    Corrections

    All material on this site has been provided by the respective publishers and authors. You can help correct errors and omissions. When requesting a correction, please mention this item's handle: RePEc:gam:jsusta:v:16:y:2024:i:8:p:3107-:d:1372330. See general information about how to correct material in RePEc.

    If you have authored this item and are not yet registered with RePEc, we encourage you to do it here. This allows to link your profile to this item. It also allows you to accept potential citations to this item that we are uncertain about.

    If CitEc recognized a bibliographic reference but did not link an item in RePEc to it, you can help with this form .

    If you know of missing items citing this one, you can help us creating those links by adding the relevant references in the same way as above, for each refering item. If you are a registered author of this item, you may also want to check the "citations" tab in your RePEc Author Service profile, as there may be some citations waiting for confirmation.

    For technical questions regarding this item, or to correct its authors, title, abstract, bibliographic or download information, contact: MDPI Indexing Manager (email available below). General contact details of provider: https://www.mdpi.com .

    Please note that corrections may take a couple of weeks to filter through the various RePEc services.

    IDEAS is a RePEc service. RePEc uses bibliographic data supplied by the respective publishers.