IDEAS home Printed from https://ideas.repec.org/a/gam/jsusta/v15y2023i23p16267-d1287028.html
   My bibliography  Save this article

Optimization Strategy for Selecting the Combination Structure of Multilayer Phase Change Material (PCM) Glazing Windows under Different Climate Zones

Author

Listed:
  • Yao Lu

    (School of Architecture and Civil Engineering, Northeast Petroleum University, Fazhan Lu Street, Daqing 163318, China
    International Joint Laboratory on Low-Carbon and New-Energy Nexus, Northeast Petroleum University, Daqing 163318, China)

  • Faisal Khaled Aldawood

    (Department of Mechanical Engineering, College of Engineering, University of Bisha, P.O. Box 001, Bisha 67714, Saudi Arabia)

  • Wanyu Hu

    (School of Architecture and Civil Engineering, Northeast Petroleum University, Fazhan Lu Street, Daqing 163318, China
    International Joint Laboratory on Low-Carbon and New-Energy Nexus, Northeast Petroleum University, Daqing 163318, China)

  • Yuxin Ma

    (Beijing Key Laboratory of Green Built Environment and Energy Efficient Technology, Beijing University of Technology, Beijing 100124, China)

  • Mohamed Kchaou

    (Department of Mechanical Engineering, College of Engineering, University of Bisha, P.O. Box 001, Bisha 67714, Saudi Arabia)

  • Chengjun Zhang

    (School of Architecture and Civil Engineering, Northeast Petroleum University, Fazhan Lu Street, Daqing 163318, China
    International Joint Laboratory on Low-Carbon and New-Energy Nexus, Northeast Petroleum University, Daqing 163318, China)

  • Xinpeng Yang

    (School of Architecture and Civil Engineering, Northeast Petroleum University, Fazhan Lu Street, Daqing 163318, China
    International Joint Laboratory on Low-Carbon and New-Energy Nexus, Northeast Petroleum University, Daqing 163318, China)

  • Ruitong Yang

    (School of Architecture and Civil Engineering, Northeast Petroleum University, Fazhan Lu Street, Daqing 163318, China
    International Joint Laboratory on Low-Carbon and New-Energy Nexus, Northeast Petroleum University, Daqing 163318, China)

  • Zitong Qi

    (School of Architecture and Civil Engineering, Northeast Petroleum University, Fazhan Lu Street, Daqing 163318, China
    International Joint Laboratory on Low-Carbon and New-Energy Nexus, Northeast Petroleum University, Daqing 163318, China)

  • Dong Li

    (School of Architecture and Civil Engineering, Northeast Petroleum University, Fazhan Lu Street, Daqing 163318, China
    International Joint Laboratory on Low-Carbon and New-Energy Nexus, Northeast Petroleum University, Daqing 163318, China)

Abstract

To improve the energy efficiency and photo-thermal performance of a double-layer PCM glazing window (DP), multilayer PCM glazing windows integrating DP (combination structures) with installations and low-e coating have been developed. However, the energy efficiency of a multilayer glazing window is not higher than DP in all climate zones. The selection of the appropriate optimization strategy of DP, i.e., selecting the most energy-saving multilayer glazing window, should take into account the specific climatic conditions. In this study, five PCM glazing windows (DP and four multilayer combination structures) are proposed. Physical heat transfer and mathematical models were conducted to numerically investigate the thermal and energy performance by Fluent in different climate zones in China. Evaluation indexes for different climate zones were established, and the energy-saving potential of each PCM glazing window was compared, and the resulting combination structure with the most energy-saving potential in each climate zone was regarded as the optimization strategy of DP. The results demonstrated that DP with the external silica aerogel has been identified as the optimization strategy for severe cold zones with 40.28% of energy saved, but it increases energy consumption in mild zones and hot summer and warm winter zones. DP with an external air layer and internal low-e coating is considered for the optimization strategies for cold zones, hot summer, and cold winter zones, and hot summer and warm winter zones, with energy-saving potential rates up to 40.67%, 46.42%, and 46.99% respectively. However, it increases energy consumption in mild zones and cold zones. In addition, DP is proven to possess the lowest energy consumption in mild zones.

Suggested Citation

  • Yao Lu & Faisal Khaled Aldawood & Wanyu Hu & Yuxin Ma & Mohamed Kchaou & Chengjun Zhang & Xinpeng Yang & Ruitong Yang & Zitong Qi & Dong Li, 2023. "Optimization Strategy for Selecting the Combination Structure of Multilayer Phase Change Material (PCM) Glazing Windows under Different Climate Zones," Sustainability, MDPI, vol. 15(23), pages 1-24, November.
  • Handle: RePEc:gam:jsusta:v:15:y:2023:i:23:p:16267-:d:1287028
    as

    Download full text from publisher

    File URL: https://www.mdpi.com/2071-1050/15/23/16267/pdf
    Download Restriction: no

    File URL: https://www.mdpi.com/2071-1050/15/23/16267/
    Download Restriction: no
    ---><---

    References listed on IDEAS

    as
    1. Wieprzkowicz, Anna & Heim, Dariusz, 2020. "Modelling of thermal processes in a glazing structure with temperature dependent optical properties - An example of PCM-window," Renewable Energy, Elsevier, vol. 160(C), pages 653-662.
    2. Lei, Jiawei & Kumarasamy, Karthikeyan & Zingre, Kishor T. & Yang, Jinglei & Wan, Man Pun & Yang, En-Hua, 2017. "Cool colored coating and phase change materials as complementary cooling strategies for building cooling load reduction in tropics," Applied Energy, Elsevier, vol. 190(C), pages 57-63.
    3. Freire, Roberto Zanetti & Mazuroski, Walter & Abadie, Marc Olivier & Mendes, Nathan, 2011. "Capacitive effect on the heat transfer through building glazing systems," Applied Energy, Elsevier, vol. 88(12), pages 4310-4319.
    4. Souayfane, Farah & Biwole, Pascal Henry & Fardoun, Farouk, 2018. "Thermal behavior of a translucent superinsulated latent heat energy storage wall in summertime," Applied Energy, Elsevier, vol. 217(C), pages 390-408.
    5. Silva, Tiago & Vicente, Romeu & Amaral, Cláudia & Figueiredo, António, 2016. "Thermal performance of a window shutter containing PCM: Numerical validation and experimental analysis," Applied Energy, Elsevier, vol. 179(C), pages 64-84.
    6. Chen, Youming & Xiao, Yaling & Zheng, Siqian & Liu, Yang & Li, Yupeng, 2018. "Dynamic heat transfer model and applicability evaluation of aerogel glazing system in various climates of China," Energy, Elsevier, vol. 163(C), pages 1115-1124.
    Full references (including those not matched with items on IDEAS)

    Most related items

    These are the items that most often cite the same works as this one and are cited by the same works as this one.
    1. Hossein Arasteh & Wahid Maref & Hamed H. Saber, 2023. "Energy and Thermal Performance Analysis of PCM-Incorporated Glazing Units Combined with Passive and Active Techniques: A Review Study," Energies, MDPI, vol. 16(3), pages 1-42, January.
    2. Jue Guo & Chong Zhang, 2022. "Utilization of Window System as Exhaust Air Heat Recovery Device and Its Energy Performance Evaluation: A Comparative Study," Energies, MDPI, vol. 15(9), pages 1-18, April.
    3. Tan, Yutong & Peng, Jinqing & Luo, Yimo & Luo, Zhengyi & Curcija, Charlie & Fang, Yueping, 2022. "Numerical heat transfer modeling and climate adaptation analysis of vacuum-photovoltaic glazing," Applied Energy, Elsevier, vol. 312(C).
    4. Dariusz Heim & Michał Krempski-Smejda & Pablo Roberto Dellicompagni & Dominika Knera & Anna Wieprzkowicz & Judith Franco, 2021. "Dynamics of Melting Process in Phase Change Material Windows Determined Based on Direct Light Transmission," Energies, MDPI, vol. 14(3), pages 1-13, January.
    5. Tomasz Kułakowski & Michał Krempski-Smejda & Dariusz Heim, 2021. "Heat Transfer with Phase Change in a Multilayer Construction: Simulation versus Experiment," Energies, MDPI, vol. 14(15), pages 1-17, July.
    6. Zhou, Yuekuan & Zheng, Siqian, 2020. "Uncertainty study on thermal and energy performances of a deterministic parameters based optimal aerogel glazing system using machine-learning method," Energy, Elsevier, vol. 193(C).
    7. Yang, Xinpeng & Li, Dong & Yang, Ruitong & Ma, Yuxin & Duan, Yanjiao & Zhang, Chengjun & Hu, Wanyu & Arıcı, Müslüm, 2023. "Parameter global optimization and climatic adaptability analysis of PCM glazed system for long-term application," Renewable Energy, Elsevier, vol. 217(C).
    8. Anatoliy M. Pavlenko & Karolina Sadko, 2023. "Evaluation of Numerical Methods for Predicting the Energy Performance of Windows," Energies, MDPI, vol. 16(3), pages 1-23, February.
    9. Liu, Changyu & Wu, Yangyang & Bian, Ji & Li, Dong & Liu, Xiaoyan, 2018. "Influence of PCM design parameters on thermal and optical performance of multi-layer glazed roof," Applied Energy, Elsevier, vol. 212(C), pages 151-161.
    10. Sun, Yuying & Hao, Yingying & Wang, Dan & Wang, Wei & Deng, Shiming & Qi, Haoran & Xue, Peng, 2022. "A predictive control strategy for electrochromic glazing to balance the visual and thermal environmental requirements: Approach and energy-saving potential assessment," Renewable Energy, Elsevier, vol. 194(C), pages 334-348.
    11. Souayfane, Farah & Biwole, Pascal Henry & Fardoun, Farouk & Achard, Patrick, 2019. "Energy performance and economic analysis of a TIM-PCM wall under different climates," Energy, Elsevier, vol. 169(C), pages 1274-1291.
    12. Sara Brito-Coimbra & Daniel Aelenei & Maria Gloria Gomes & Antonio Moret Rodrigues, 2021. "Building Façade Retrofit with Solar Passive Technologies: A Literature Review," Energies, MDPI, vol. 14(6), pages 1-18, March.
    13. Zhuang, Chaoqun & Gao, Yafeng & Zhao, Yingru & Levinson, Ronnen & Heiselberg, Per & Wang, Zhiqiang & Guo, Rui, 2021. "Potential benefits and optimization of cool-coated office buildings: A case study in Chongqing, China," Energy, Elsevier, vol. 226(C).
    14. Agnieszka Żelazna & Lech Lichołai & Joanna Krasoń & Przemysław Miąsik & Dominika Mikušová, 2023. "The Effects of Using a Trombe Wall Modified with a Phase Change Material, from the Perspective of a Building’s Life Cycle," Energies, MDPI, vol. 16(23), pages 1-19, November.
    15. Wang, Pengcheng & Liu, Zhongbing & Zhang, Ling & Wang, Zhe & Fan, Jianhua, 2023. "Inversion of extinction coefficient and refractive index of variable transparency solid–solid phase change material based on a hybrid model under real climatic conditions," Applied Energy, Elsevier, vol. 341(C).
    16. Przemysław Miąsik & Joanna Krasoń, 2021. "Thermal Efficiency of Trombe Wall in the South Facade of a Frame Building," Energies, MDPI, vol. 14(3), pages 1-23, January.
    17. Kong, Xiangfei & Jiang, Lina & Yuan, Ye & Qiao, Xu, 2022. "Experimental study on the performance of an active novel vertical partition thermal storage wallboard based on composite phase change material with porous silica and microencapsulation," Energy, Elsevier, vol. 239(PE).
    18. Liu, Xianjie & Feng, Qian & Peng, Zhigang & Zheng, Yong & Liu, Huan, 2020. "Preparation and evaluation of micro-encapsulated thermal control materials for oil well cement slurry," Energy, Elsevier, vol. 208(C).
    19. Agustín Torres Rodríguez & David Morillón Gálvez & Iván García Kerdan & Rodolfo Silva Casarín, 2023. "A Comparison of a Transparent Thermal Insulation System Filled with Refrigerants and a Pig-Fat Based PCM," Energies, MDPI, vol. 16(9), pages 1-28, April.
    20. Xu, Bin & Chen, Xing-ni & Fei, Yue & Gan, Wen-tao & Pei, Gang, 2023. "Optimizing the applicability of cool paint through phase change material according to the energy consumption characteristics in different regions," Renewable Energy, Elsevier, vol. 212(C), pages 953-971.

    Corrections

    All material on this site has been provided by the respective publishers and authors. You can help correct errors and omissions. When requesting a correction, please mention this item's handle: RePEc:gam:jsusta:v:15:y:2023:i:23:p:16267-:d:1287028. See general information about how to correct material in RePEc.

    If you have authored this item and are not yet registered with RePEc, we encourage you to do it here. This allows to link your profile to this item. It also allows you to accept potential citations to this item that we are uncertain about.

    If CitEc recognized a bibliographic reference but did not link an item in RePEc to it, you can help with this form .

    If you know of missing items citing this one, you can help us creating those links by adding the relevant references in the same way as above, for each refering item. If you are a registered author of this item, you may also want to check the "citations" tab in your RePEc Author Service profile, as there may be some citations waiting for confirmation.

    For technical questions regarding this item, or to correct its authors, title, abstract, bibliographic or download information, contact: MDPI Indexing Manager (email available below). General contact details of provider: https://www.mdpi.com .

    Please note that corrections may take a couple of weeks to filter through the various RePEc services.

    IDEAS is a RePEc service. RePEc uses bibliographic data supplied by the respective publishers.