IDEAS home Printed from https://ideas.repec.org/a/gam/jsusta/v15y2023i17p12972-d1227179.html
   My bibliography  Save this article

Influence of Opposing Exterior Window Geometry on the Carbon Emissions of Indoor Lighting under the Combined Effect of Natural Lighting and Artificial Lighting in the City of Shenyang, China

Author

Listed:
  • Jianhua Ding

    (Jangho Architecture College, Northeastern University, Shenyang 110102, China)

  • Xinyi Zou

    (Jangho Architecture College, Northeastern University, Shenyang 110102, China)

  • Murong Lv

    (Jangho Architecture College, Northeastern University, Shenyang 110102, China)

Abstract

According to relevant statistics, the electricity consumption for lighting in university buildings accounts for 20 to 40% of the total energy consumption of the buildings. Lighting energy saving is a key influential factor in achieving a low-carbon campus construction. The electricity consumption for lighting is simultaneously affected by the utilization of natural daylight and artificial lighting schemes. Currently, there is a lack of research regarding the dynamic quantitative correlation between the geometric design of external windows affecting the utilization of natural daylight and carbon emissions. Also, research on the dynamic synergistic impact between natural light utilization and artificial lighting on carbon emissions has not been observed. Hence, there is a lack of quantitative carbon impact prediction and guidance in the early design and actual operation of such spaces. This study took the professional drawing space of a university in the severe cold regions of Shenyang as a prototype. Daylight factor (DF) and spatial daylight autonomy (sDA) were determined using Rhino + Grasshopper and Ladybug + Honeybee for window geometry. DIALux evo simulation was used to analyze the carbon emissions of space operation, followed by correlation analysis and multiple linear regression analysis using SPSS to determine the degree of influence of each window design parameter on the carbon emissions. The window-to-floor ratio (WFR), window-to-wall ratio (WWR), windowsill height (H ws ), window width (W w ), and window height (H w ) had inhibitory effects on carbon emissions from daylight-responsive artificial lighting (C), and the influence of different orientations was different. Under the condition of an opposing window, the overall C trend of the professional drawing space was west < east< south < north, and the C of the morning period in each orientation was significantly lower than that in the afternoon period. Taking the frame structure system space with a floor-to-floor height of 4.2 m as an example, within the requirements of WFR and WWR, the C of the west-facing professional drawing classroom with 2.55 m for H w , 0.75 m for H ws , and 9.6 m for W w was the smallest. To a certain extent, opening large windows and opening high windows can reduce the C of the space.

Suggested Citation

  • Jianhua Ding & Xinyi Zou & Murong Lv, 2023. "Influence of Opposing Exterior Window Geometry on the Carbon Emissions of Indoor Lighting under the Combined Effect of Natural Lighting and Artificial Lighting in the City of Shenyang, China," Sustainability, MDPI, vol. 15(17), pages 1-20, August.
  • Handle: RePEc:gam:jsusta:v:15:y:2023:i:17:p:12972-:d:1227179
    as

    Download full text from publisher

    File URL: https://www.mdpi.com/2071-1050/15/17/12972/pdf
    Download Restriction: no

    File URL: https://www.mdpi.com/2071-1050/15/17/12972/
    Download Restriction: no
    ---><---

    References listed on IDEAS

    as
    1. Dušan Katunský & Marián Vertaľ & Erika Dolníková & Silvia Zozuláková & Kristián Hutkai & Zuzana Dická, 2022. "Mutual Interaction of Daylight and Overheating in the Attic Space in Summer Time," Sustainability, MDPI, vol. 14(23), pages 1-25, November.
    2. Salata, Ferdinando & Golasi, Iacopo & di Salvatore, Maicol & de Lieto Vollaro, Andrea, 2016. "Energy and reliability optimization of a system that combines daylighting and artificial sources. A case study carried out in academic buildings," Applied Energy, Elsevier, vol. 169(C), pages 250-266.
    3. Freitas, Jader de Sousa & Cronemberger, Joára & Soares, Raí Mariano & Amorim, Cláudia Naves David, 2020. "Modeling and assessing BIPV envelopes using parametric Rhinoceros plugins Grasshopper and Ladybug," Renewable Energy, Elsevier, vol. 160(C), pages 1468-1479.
    4. Li, Danny H.W. & Cheung, K.L. & Wong, S.L. & Lam, Tony N.T., 2010. "An analysis of energy-efficient light fittings and lighting controls," Applied Energy, Elsevier, vol. 87(2), pages 558-567, February.
    5. Dušan Katunský & Erika Dolníková & Bystrík Dolník, 2018. "Daytime Lighting Assessment in Textile Factories Using Connected Windows in Slovakia: A Case Study," Sustainability, MDPI, vol. 10(3), pages 1-20, February.
    Full references (including those not matched with items on IDEAS)

    Most related items

    These are the items that most often cite the same works as this one and are cited by the same works as this one.
    1. Carla Balocco & Martina Cecchi & Giulia Volante, 2019. "Natural Lighting for Sustainability of Cultural Heritage Refurbishment," Sustainability, MDPI, vol. 11(18), pages 1-17, September.
    2. Han, Zhong & Tian, Liting & Cheng, Lin, 2021. "A deducing-based reliability optimization for electrical equipment with constant failure rate components duration their mission profile," Reliability Engineering and System Safety, Elsevier, vol. 212(C).
    3. Kenji Araki & Yasuyuki Ota & Akira Nagaoka & Kensuke Nishioka, 2023. "3D Solar Irradiance Model for Non-Uniform Shading Environments Using Shading (Aperture) Matrix Enhanced by Local Coordinate System," Energies, MDPI, vol. 16(11), pages 1-20, May.
    4. Alrubaih, M.S. & Zain, M.F.M. & Alghoul, M.A. & Ibrahim, N.L.N. & Shameri, M.A. & Elayeb, Omkalthum, 2013. "Research and development on aspects of daylighting fundamentals," Renewable and Sustainable Energy Reviews, Elsevier, vol. 21(C), pages 494-505.
    5. Niemelä, Tuomo & Kosonen, Risto & Jokisalo, Juha, 2016. "Cost-optimal energy performance renovation measures of educational buildings in cold climate," Applied Energy, Elsevier, vol. 183(C), pages 1005-1020.
    6. Lou, Siwei & Li, Danny H.W. & Lam, Joseph C., 2017. "CIE Standard Sky classification by accessible climatic indices," Renewable Energy, Elsevier, vol. 113(C), pages 347-356.
    7. Chitnis, Dipti & Thejo kalyani, N. & Swart, H.C. & Dhoble, S.J., 2016. "Escalating opportunities in the field of lighting," Renewable and Sustainable Energy Reviews, Elsevier, vol. 64(C), pages 727-748.
    8. Singh, Ramkishore & Lazarus, I.J. & Kishore, V.V.N., 2015. "Effect of internal woven roller shade and glazing on the energy and daylighting performances of an office building in the cold climate of Shillong," Applied Energy, Elsevier, vol. 159(C), pages 317-333.
    9. Chen, Qian & Oh, Seung Jin & Burhan, Muhammad, 2020. "Design and optimization of a novel electrowetting-driven solar-indoor lighting system," Applied Energy, Elsevier, vol. 269(C).
    10. Weifan Long & Xiaofei Chen & Qingsong Ma & Xindong Wei & Qiao Xi, 2022. "An Evaluation of the PV Integrated Dynamic Overhangs Based on Parametric Performance Design Method: A Case Study of a Student Apartment in China," Sustainability, MDPI, vol. 14(13), pages 1-18, June.
    11. Federico Minelli & Diana D’Agostino & Maria Migliozzi & Francesco Minichiello & Pierpaolo D’Agostino, 2023. "PhloVer: A Modular and Integrated Tracking Photovoltaic Shading Device for Sustainable Large Urban Spaces—Preliminary Study and Prototyping," Energies, MDPI, vol. 16(15), pages 1-35, August.
    12. Fei Cao & Heng Zhang & Hao Zhou & Na Lu, 2018. "Transient Performance Analysis of the Solar Optical Guide Lighting System in Building Groups," Energies, MDPI, vol. 11(11), pages 1-13, October.
    13. Silvia Cesari & Paolo Valdiserri & Maddalena Coccagna & Sante Mazzacane, 2020. "The Energy Saving Potential of Wide Windows in Hospital Patient Rooms, Optimizing the Type of Glazing and Lighting Control Strategy under Different Climatic Conditions," Energies, MDPI, vol. 13(8), pages 1-24, April.
    14. Ikuzwe, Alice & Ye, Xianming & Xia, Xiaohua, 2020. "Energy-maintenance optimization for retrofitted lighting system incorporating luminous flux degradation to enhance visual comfort," Applied Energy, Elsevier, vol. 261(C).
    15. Ferdinando Salata & Iacopo Golasi & Alessandro Poliziani & Antonio Futia & Emanuele De Lieto Vollaro & Massimo Coppi & Andrea De Lieto Vollaro, 2016. "Management Optimization of the Luminous Flux Regulation of a Lighting System in Road Tunnels. A First Approach to the Exertion of Predictive Control Systems," Sustainability, MDPI, vol. 8(11), pages 1-17, October.
    16. Li, Y. & Arulnathan, V. & Heidari, M.D. & Pelletier, N., 2022. "Design considerations for net zero energy buildings for intensive, confined poultry production: A review of current insights, knowledge gaps, and future directions," Renewable and Sustainable Energy Reviews, Elsevier, vol. 154(C).
    17. Habibi, Shahryar & Kamel, Ehsan & Memari, Ali M., 2024. "Design strategies for addressing COVID-19 issues in buildings," Energy, Elsevier, vol. 293(C).
    18. Débora Thomé Miranda & Douglas Barreto & Inês Flores-Colen, 2024. "An Evaluation of the Luminous Performance of a School Environment Integrating Artificial Lighting and Daylight," Sustainability, MDPI, vol. 16(4), pages 1-16, February.
    19. Jing, Yifan & Zhu, Li & Yin, Baoquan & Li, Fangfang, 2023. "Evaluating the PV system expansion potential of existing integrated energy parks: A case study in North China," Applied Energy, Elsevier, vol. 330(PA).
    20. Xue, Peng & Li, Qian & Xie, Jingchao & Zhao, Mengjing & Liu, Jiaping, 2019. "Optimization of window-to-wall ratio with sunshades in China low latitude region considering daylighting and energy saving requirements," Applied Energy, Elsevier, vol. 233, pages 62-70.

    Corrections

    All material on this site has been provided by the respective publishers and authors. You can help correct errors and omissions. When requesting a correction, please mention this item's handle: RePEc:gam:jsusta:v:15:y:2023:i:17:p:12972-:d:1227179. See general information about how to correct material in RePEc.

    If you have authored this item and are not yet registered with RePEc, we encourage you to do it here. This allows to link your profile to this item. It also allows you to accept potential citations to this item that we are uncertain about.

    If CitEc recognized a bibliographic reference but did not link an item in RePEc to it, you can help with this form .

    If you know of missing items citing this one, you can help us creating those links by adding the relevant references in the same way as above, for each refering item. If you are a registered author of this item, you may also want to check the "citations" tab in your RePEc Author Service profile, as there may be some citations waiting for confirmation.

    For technical questions regarding this item, or to correct its authors, title, abstract, bibliographic or download information, contact: MDPI Indexing Manager (email available below). General contact details of provider: https://www.mdpi.com .

    Please note that corrections may take a couple of weeks to filter through the various RePEc services.

    IDEAS is a RePEc service. RePEc uses bibliographic data supplied by the respective publishers.