IDEAS home Printed from https://ideas.repec.org/a/gam/jeners/v11y2018i9p2402-d169181.html
   My bibliography  Save this article

The Thermal Behavior of a Dual-Function Solar Collector Integrated with Building: An Experimental and Numerical Study on the Air Heating Mode

Author

Listed:
  • Jinwei Ma

    (School of Environment and Energy Engineering, Anhui Jianzhu University, Hefei 230601, China)

  • Qiang Zhao

    (School of Environment and Energy Engineering, Anhui Jianzhu University, Hefei 230601, China)

  • Yuehong Su

    (Department of Architecture and Built Environment, University of Nottingham, Nottingham NG7 2RD, UK)

  • Jie Ji

    (Department of Thermal Science and Energy Engineering, University of Science and Technology of China, Hefei 230026, China)

  • Wei He

    (Department of Building Environment and Equipment, Hefei University of Technology, Hefei 230009, China)

  • Zhongting Hu

    (Department of Building Environment and Equipment, Hefei University of Technology, Hefei 230009, China)

  • Tingyong Fang

    (Anhui Province Key Laboratory of Intelligent Building & Building Energy Saving, Hefei 230601, China)

  • Haitao Wang

    (Anhui Province Key Laboratory of Intelligent Building & Building Energy Saving, Hefei 230601, China)

Abstract

This paper presented a novel solar collector that can work in air or water heating mode depending on the seasonal requirement. The dual-function solar collector (DFSC) integrated with a building as well as a reference building without the DFSC were built to test thermal behavior in passive air heating mode during winter. The buildings were equipped with an apparatus to control the room temperature. During the testing procedure, experimental study on the DFSC system was carried out under two conditions, where the indoor temperature was controlled and non-controlled. The results showed that the average temperature of the test room was about 3.43 °C higher than that of the reference room under the non-controlled condition. When the room temperature was controlled at 18 °C, the power consumptions of the test room and reference room were 4.322 kWh and 7.796 kWh, respectively. Consequently, the corresponding daily power consumption saved could reach up to around 3.5 kWh. Moreover, a dynamic numerical model on the DFSC along with the building was developed taking the fin effect of the Cu-tubes into account. The numerical results are found to be well consistent with the measured data. A parametric study on with/without Cu-tubes and depth of the air channel was carried out. It is found that the existing Cu-tubes functioning as water heating can enhance the air heating efficiency when the depth of air channel is of a suitable size.

Suggested Citation

  • Jinwei Ma & Qiang Zhao & Yuehong Su & Jie Ji & Wei He & Zhongting Hu & Tingyong Fang & Haitao Wang, 2018. "The Thermal Behavior of a Dual-Function Solar Collector Integrated with Building: An Experimental and Numerical Study on the Air Heating Mode," Energies, MDPI, vol. 11(9), pages 1-18, September.
  • Handle: RePEc:gam:jeners:v:11:y:2018:i:9:p:2402-:d:169181
    as

    Download full text from publisher

    File URL: https://www.mdpi.com/1996-1073/11/9/2402/pdf
    Download Restriction: no

    File URL: https://www.mdpi.com/1996-1073/11/9/2402/
    Download Restriction: no
    ---><---

    References listed on IDEAS

    as
    1. Ghrab-Morcos, Nadia & Bouden, Chiheb & Franchisseur, Robert, 1993. "Overheating caused by passive solar elements in Tunis. Effectiveness of some ways to prevent it," Renewable Energy, Elsevier, vol. 3(6), pages 801-811.
    2. Hu, Zhongting & He, Wei & Ji, Jie & Zhang, Shengyao, 2017. "A review on the application of Trombe wall system in buildings," Renewable and Sustainable Energy Reviews, Elsevier, vol. 70(C), pages 976-987.
    3. Ji, Jie & Luo, Chenglong & Chow, Tin-Tai & Sun, Wei & He, Wei, 2011. "Thermal characteristics of a building-integrated dual-function solar collector in water heating mode with natural circulation," Energy, Elsevier, vol. 36(1), pages 566-574.
    4. Sergio L. González-González & Ana Tejero-González & Francisco J. Rey-Martínez & Manuel Andrés-Chicote, 2017. "Alternative for Summer Use of Solar Air Heaters in Existing Buildings," Energies, MDPI, vol. 10(7), pages 1-15, July.
    5. Ma, Qingsong & Fukuda, Hiroatsu & Lee, Myonghyang & Kobatake, Takumi & Kuma, Yuko & Ozaki, Akihito, 2018. "Study on the utilization of heat in the mechanically ventilated Trombe wall in a house with a central air conditioning and air circulation system," Applied Energy, Elsevier, vol. 222(C), pages 861-871.
    6. Sun, Wei & Ji, Jie & Luo, Chenglong & He, Wei, 2011. "Performance of PV-Trombe wall in winter correlated with south façade design," Applied Energy, Elsevier, vol. 88(1), pages 224-231, January.
    7. Imessad, K. & Messaoudene, N.Ait & Belhamel, M., 2004. "Performances of the Barra–Costantini passive heating system under Algerian climate conditions," Renewable Energy, Elsevier, vol. 29(3), pages 357-367.
    Full references (including those not matched with items on IDEAS)

    Citations

    Citations are extracted by the CitEc Project, subscribe to its RSS feed for this item.
    as


    Cited by:

    1. Piotr Olczak & Dominika Matuszewska & Jadwiga Zabagło, 2020. "The Comparison of Solar Energy Gaining Effectiveness between Flat Plate Collectors and Evacuated Tube Collectors with Heat Pipe: Case Study," Energies, MDPI, vol. 13(7), pages 1-14, April.

    Most related items

    These are the items that most often cite the same works as this one and are cited by the same works as this one.
    1. Hong, Xiaoqiang & Leung, Michael K.H. & He, Wei, 2019. "Effective use of venetian blind in Trombe wall for solar space conditioning control," Applied Energy, Elsevier, vol. 250(C), pages 452-460.
    2. Abdulmajeed Mohamad & Jan Taler & Paweł Ocłoń, 2019. "Trombe Wall Utilization for Cold and Hot Climate Conditions," Energies, MDPI, vol. 12(2), pages 1-18, January.
    3. Xiao, Yuling & Yang, Qianli & Fei, Fan & Li, Kai & Jiang, Yijun & Zhang, Yuanwen & Fukuda, Hiroatsu & Ma, Qingsong, 2024. "Review of Trombe wall technology: Trends in optimization," Renewable and Sustainable Energy Reviews, Elsevier, vol. 200(C).
    4. Xie, Hao & Yu, Bendong & Wang, Jun & Ji, Jie, 2021. "A novel disinfected Trombe wall for space heating and virus inactivation: Concept and performance investigation," Applied Energy, Elsevier, vol. 291(C).
    5. Wang, Dengjia & Hu, Liang & Du, Hu & Liu, Yanfeng & Huang, Jianxiang & Xu, Yanchao & Liu, Jiaping, 2020. "Classification, experimental assessment, modeling methods and evaluation metrics of Trombe walls," Renewable and Sustainable Energy Reviews, Elsevier, vol. 124(C).
    6. Xiao, Lan & Qin, Liang-Liang & Wu, Shuang-Ying, 2023. "Effect of PV-Trombe wall in the multi-storey building on standard effective temperature (SET)-based indoor thermal comfort," Energy, Elsevier, vol. 263(PB).
    7. Zhang, Lili & Hou, Yuyao & Liu, Zu’an & Du, Junfei & Xu, Long & Zhang, Guomin & Shi, Long, 2020. "Trombe wall for a residential building in Sichuan-Tibet alpine valley – A case study," Renewable Energy, Elsevier, vol. 156(C), pages 31-46.
    8. He, Wei & Hong, Xiaoqiang & Luo, Bingqing & Chen, Hongbing & Ji, Jie, 2016. "CFD and comparative study on the dual-function solar collectors with and without tile-shaped covers in water heating mode," Renewable Energy, Elsevier, vol. 86(C), pages 1205-1214.
    9. Qingsong Ma & Hiroatsu Fukuda & Takumi Kobatake & Myonghyang Lee, 2017. "Study of a Double-Layer Trombe Wall Assisted by a Temperature-Controlled DC Fan for Heating Seasons," Sustainability, MDPI, vol. 9(12), pages 1-12, November.
    10. Dong, Jiankai & Chen, Zhihua & Zhang, Long & Cheng, Yuanda & Sun, Suyuting & Jie, Jia, 2019. "Experimental investigation on the heating performance of a novel designed trombe wall," Energy, Elsevier, vol. 168(C), pages 728-736.
    11. Ke, Wei & Ji, Jie & Wang, Chuyao & Zhang, Chengyan & Xie, Hao & Tang, Yayun & Lin, Yuan, 2022. "Comparative analysis on the electrical and thermal performance of two CdTe multi-layer ventilated windows with and without a middle PCM layer: A preliminary numerical study," Renewable Energy, Elsevier, vol. 189(C), pages 1306-1323.
    12. Wang, Chuyao & Ji, Jie & Zhang, Chengyan & Ke, Wei & Tang, Yayun & Tian, Xinyi, 2022. "Experimental and numerical investigation of a multi-functional photovoltaic/thermal wall: A practical application in the civil building," Energy, Elsevier, vol. 241(C).
    13. Ke, Wei & Ji, Jie & Xu, Lijie & Yu, Bendong & Tian, Xinyi & Wang, Jun, 2021. "Numerical study and experimental validation of a multi-functional dual-air-channel solar wall system with PCM," Energy, Elsevier, vol. 227(C).
    14. Hu, Zhongting & He, Wei & Hu, Dengyun & Lv, Song & Wang, Liping & Ji, Jie & Chen, Hongbing & Ma, Jinwei, 2017. "Design, construction and performance testing of a PV blind-integrated Trombe wall module," Applied Energy, Elsevier, vol. 203(C), pages 643-656.
    15. Yu, Bendong & Hou, Jingxin & He, Wei & Liu, Shanshan & Hu, Zhongting & Ji, Jie & Chen, Hongbing & Xu, Gang, 2018. "Study on a high-performance photocatalytic-Trombe wall system for space heating and air purification," Applied Energy, Elsevier, vol. 226(C), pages 365-380.
    16. Ke, Wei & Ji, Jie & Zhang, Chengyan & Xie, Hao & Tang, Yayun & Wang, Chuyao, 2023. "Effects of the PCM layer position on the comprehensive performance of a built-middle PV-Trombe wall system for building application in the heating season," Energy, Elsevier, vol. 267(C).
    17. Yu, Bendong & Li, Niansi & Yan, Chengchu & Liu, Xiaoyong & Liu, Huifang & Ji, Jie & Xu, Xiaoping, 2022. "The comprehensive performance analysis on a novel high-performance air-purification-sterilization type PV-Trombe wall," Renewable Energy, Elsevier, vol. 182(C), pages 1201-1218.
    18. Sergei, Kostikov & Shen, Chao & Jiang, Yiqiang, 2020. "A review of the current work potential of a trombe wall," Renewable and Sustainable Energy Reviews, Elsevier, vol. 130(C).
    19. Si, Pengfei & Lv, Yuexia & Rong, Xiangyang & Shi, Lijun & Yan, Jinyue & Wang, Xin, 2020. "An innovative building envelope with variable thermal performance for passive heating systems," Applied Energy, Elsevier, vol. 269(C).
    20. Ke, Wei & Ji, Jie & Xu, Lijie & Xie, Hao & Wang, Chuyao & Yu, Bendong, 2021. "Annual performance analysis of a dual-air-channel solar wall system with phase change material in different climate regions of China," Energy, Elsevier, vol. 235(C).

    Corrections

    All material on this site has been provided by the respective publishers and authors. You can help correct errors and omissions. When requesting a correction, please mention this item's handle: RePEc:gam:jeners:v:11:y:2018:i:9:p:2402-:d:169181. See general information about how to correct material in RePEc.

    If you have authored this item and are not yet registered with RePEc, we encourage you to do it here. This allows to link your profile to this item. It also allows you to accept potential citations to this item that we are uncertain about.

    If CitEc recognized a bibliographic reference but did not link an item in RePEc to it, you can help with this form .

    If you know of missing items citing this one, you can help us creating those links by adding the relevant references in the same way as above, for each refering item. If you are a registered author of this item, you may also want to check the "citations" tab in your RePEc Author Service profile, as there may be some citations waiting for confirmation.

    For technical questions regarding this item, or to correct its authors, title, abstract, bibliographic or download information, contact: MDPI Indexing Manager (email available below). General contact details of provider: https://www.mdpi.com .

    Please note that corrections may take a couple of weeks to filter through the various RePEc services.

    IDEAS is a RePEc service. RePEc uses bibliographic data supplied by the respective publishers.