Parameter sensitivity analysis and configuration optimization of indirect evaporative cooler (IEC) considering condensation

Author

Listed:
  • Chen, Yi
  • Yang, Hongxing
  • Luo, Yimo

Abstract

The indirect evaporative cooler (IEC) is a low-carbon device which cools the air with water evaporation. Its performances in dry regions have been investigated intensively. However, its application in hot and humid regions, where the IEC is used as a pre-cooling device in an air-conditioning system, is still at developing stage. The exhausted air from air-conditioned space is humidified and used as secondary air to pre-cool the fresh air. As the dew point temperature of the fresh air is high, condensation may occur in the dry channels. However, the parameter sensitivity analysis of IEC with condensation is lacking. Besides, the optimized IEC configuration may be different from that of dry regions because of distinguished air handling process. So the sensitivity analysis among seven parameters by orthogonal test was conducted based on the experimental-validated IEC model emphasizing on condensation condition. The optimization was then conducted to the most influential and engineering controllable parameters. The results indicate the channel gap and cooler height are the key influential factors on IEC thermal performance. The optimized channel gap is 2–3mm and 3–4mm under condensation and non-condensation state, respectively. The optimized NTUp is 4–7 and 3–5, respectively.

Suggested Citation

  • Chen, Yi & Yang, Hongxing & Luo, Yimo, 2017. "Parameter sensitivity analysis and configuration optimization of indirect evaporative cooler (IEC) considering condensation," Applied Energy, Elsevier, vol. 194(C), pages 440-453.
  • Handle: RePEc:eee:appene:v:194:y:2017:i:c:p:440-453
    DOI: 10.1016/j.apenergy.2016.06.121
    as

    Download full text from publisher

    File URL: http://www.sciencedirect.com/science/article/pii/S0306261916308960
    Download Restriction: Full text for ScienceDirect subscribers only

    File URL: https://libkey.io/10.1016/j.apenergy.2016.06.121?utm_source=ideas
    LibKey link: if access is restricted and if your library uses this service, LibKey will redirect you to where you can use your library subscription to access this item
    ---><---

    As the access to this document is restricted, you may want to search for a different version of it.

    References listed on IDEAS

    as
    1. Hsu, Shyr Tzer & Lavan, Zalman & Worek, William M., 1989. "Optimization of wet-surface heat exchangers," Energy, Elsevier, vol. 14(11), pages 757-770.
    2. Xuan, Y.M. & Xiao, F. & Niu, X.F. & Huang, X. & Wang, S.W., 2012. "Research and application of evaporative cooling in China: A review (I) – Research," Renewable and Sustainable Energy Reviews, Elsevier, vol. 16(5), pages 3535-3546.
    3. Chua, K.J. & Chou, S.K. & Yang, W.M. & Yan, J., 2013. "Achieving better energy-efficient air conditioning – A review of technologies and strategies," Applied Energy, Elsevier, vol. 104(C), pages 87-104.
    4. Jradi, M. & Riffat, S., 2014. "Experimental and numerical investigation of a dew-point cooling system for thermal comfort in buildings," Applied Energy, Elsevier, vol. 132(C), pages 524-535.
    5. Cui, X. & Chua, K.J. & Yang, W.M., 2014. "Numerical simulation of a novel energy-efficient dew-point evaporative air cooler," Applied Energy, Elsevier, vol. 136(C), pages 979-988.
    6. Xuan, Y.M. & Xiao, F. & Niu, X.F. & Huang, X. & Wang, S.W., 2012. "Research and applications of evaporative cooling in China: A review (II)—Systems and equipment," Renewable and Sustainable Energy Reviews, Elsevier, vol. 16(5), pages 3523-3534.
    7. Maheshwari, G. P. & Al-Ragom, F. & Suri, R. K., 2001. "Energy-saving potential of an indirect evaporative cooler," Applied Energy, Elsevier, vol. 69(1), pages 69-76, May.
    8. Bajwa, Maqsood & Aksugur, Erdal & Al-Otaibi, Ghazi, 1993. "The potential of the evaporative cooling techniques in the gulf region of the Kingdom of Saudi Arabia," Renewable Energy, Elsevier, vol. 3(1), pages 15-29.
    9. Yuan, Fang & Chen, Qun, 2012. "A global optimization method for evaporative cooling systems based on the entransy theory," Energy, Elsevier, vol. 42(1), pages 181-191.
    10. Duan, Zhiyin & Zhan, Changhong & Zhang, Xingxing & Mustafa, Mahmud & Zhao, Xudong & Alimohammadisagvand, Behrang & Hasan, Ala, 2012. "Indirect evaporative cooling: Past, present and future potentials," Renewable and Sustainable Energy Reviews, Elsevier, vol. 16(9), pages 6823-6850.
    11. Anisimov, Sergey & Pandelidis, Demis & Jedlikowski, Andrzej, 2015. "Performance study of the indirect evaporative air cooler and heat recovery exchanger in air conditioning system during the summer and winter operation," Energy, Elsevier, vol. 89(C), pages 205-225.
    12. Anisimov, Sergey & Pandelidis, Demis & Danielewicz, Jan, 2015. "Numerical study and optimization of the combined indirect evaporative air cooler for air-conditioning systems," Energy, Elsevier, vol. 80(C), pages 452-464.
    Full references (including those not matched with items on IDEAS)

    Citations

    Citations are extracted by the CitEc Project, subscribe to its RSS feed for this item.
    as


    Cited by:

    1. Tariq, Rasikh & Sheikh, Nadeem Ahmed & Xamán, J. & Bassam, A., 2018. "An innovative air saturator for humidification-dehumidification desalination application," Applied Energy, Elsevier, vol. 228(C), pages 789-807.
    2. Chen, Yi & Yan, Huaxia & Luo, Yimo & Yang, Hongxing, 2019. "A proportional–integral (PI) law based variable speed technology for temperature control in indirect evaporative cooling system," Applied Energy, Elsevier, vol. 251(C), pages 1-1.
    3. Rasaq Adekunle Olabomi & Bakar Jaafar & Md Nor Musa & Shamsul Sarip, 2022. "Soil Temperature Control For Growing Of High-Value Temperate Crops On Tropical Lowland," Malaysian Journal of Sustainable Agriculture (MJSA), Zibeline International Publishing, vol. 6(1), pages 57-64, October.
    4. Zhang, Hongkuan & Ma, Hongting & Ma, Shuo, 2022. "Energy, exergy, economic and environmental analysis of an indirect evaporative cooling integrated with liquid dehumidification," Energy, Elsevier, vol. 253(C).
    5. Pang, Zhihong & O'Neill, Zheng, 2018. "Uncertainty quantification and sensitivity analysis of the domestic hot water usage in hotels," Applied Energy, Elsevier, vol. 232(C), pages 424-442.
    6. Li, Wuyan & Li, Yongcai & Shi, Wenxing & Lu, Jun, 2021. "Energy and exergy study on indirect evaporative cooler used in exhaust air heat recovery," Energy, Elsevier, vol. 235(C).
    7. Chen, Yi & Yan, Huaxia & Yang, Hongxing, 2018. "Comparative study of on-off control and novel high-low control of regenerative indirect evaporative cooler (RIEC)," Applied Energy, Elsevier, vol. 225(C), pages 233-243.
    8. Zheng, Bin & Guo, Chunmei & Chen, Tong & Shi, Qi & Lv, Jian & You, Yuwen, 2019. "Development of an experimental validated model of cross-flow indirect evaporative cooler with condensation," Applied Energy, Elsevier, vol. 252(C), pages 1-1.
    9. Li, Wuyan & Wang, Jue & Shi, Wenxing & Lu, Jun, 2022. "High-efficiency cooling solution for exhaust air heat pump: Modeling and experimental validation," Energy, Elsevier, vol. 254(PB).
    10. Qian Chen & Muhammad Burhan & M Kum Ja & Muhammad Wakil Shahzad & Doskhan Ybyraiymkul & Hongfei Zheng & Xin Cui & Kim Choon Ng, 2022. "Hybrid Indirect Evaporative Cooling-Mechanical Vapor Compression System: A Mini-Review," Energies, MDPI, vol. 15(20), pages 1-17, October.
    11. Ma, Xiaochen & Shi, Wenchao & Yang, Hongxing, 2022. "Study on water spraying distribution to improve the energy recovery performance of indirect evaporative coolers with nozzle arrangement optimization," Applied Energy, Elsevier, vol. 318(C).
    12. Min, Yunran & Chen, Yi & Shi, Wenchao & Yang, Hongxing, 2021. "Applicability of indirect evaporative cooler for energy recovery in hot and humid areas: Comparison with heat recovery wheel," Applied Energy, Elsevier, vol. 287(C).
    13. Seong-Bhin Kim & Kwang-Am Moon & Hwi-Ung Choi & Kwang-Hwan Choi, 2024. "Experimental Study on the Performance of an Air Conditioning Unit with a Baffled Indirect Evaporative Cooler," Energies, MDPI, vol. 17(13), pages 1-13, July.
    14. Peng Wang & Xingqi Luo & Jinling Lu & Qiyao Xue & Jiawei Gao & Senlin Chen, 2022. "Energy and Economic Analysis of Power Generation Using Residual Pressure of a Circulating Cooling Water System," Sustainability, MDPI, vol. 14(19), pages 1-20, October.
    15. Yang, Hongxing & Shi, Wenchao & Chen, Yi & Min, Yunran, 2021. "Research development of indirect evaporative cooling technology: An updated review," Renewable and Sustainable Energy Reviews, Elsevier, vol. 145(C).
    16. Rampazzo, Mirco & Lionello, Michele & Beghi, Alessandro & Sisti, Enrico & Cecchinato, Luca, 2019. "A static moving boundary modelling approach for simulation of indirect evaporative free cooling systems," Applied Energy, Elsevier, vol. 250(C), pages 1719-1728.

    Most related items

    These are the items that most often cite the same works as this one and are cited by the same works as this one.
    1. Mahmood, Muhammad H. & Sultan, Muhammad & Miyazaki, Takahiko & Koyama, Shigeru & Maisotsenko, Valeriy S., 2016. "Overview of the Maisotsenko cycle – A way towards dew point evaporative cooling," Renewable and Sustainable Energy Reviews, Elsevier, vol. 66(C), pages 537-555.
    2. Shahzad, Muhammad Wakil & Lin, Jie & Xu, Ben Bin & Dala, Laurent & Chen, Qian & Burhan, Muhammad & Sultan, Muhammad & Worek, William & Ng, Kim Choon, 2021. "A spatiotemporal indirect evaporative cooler enabled by transiently interceding water mist," Energy, Elsevier, vol. 217(C).
    3. Pandelidis, Demis & Anisimov, Sergey & Rajski, Krzysztof & Brychcy, Ewa & Sidorczyk, Marek, 2017. "Performance comparison of the advanced indirect evaporative air coolers," Energy, Elsevier, vol. 135(C), pages 138-152.
    4. Yang, Hongxing & Shi, Wenchao & Chen, Yi & Min, Yunran, 2021. "Research development of indirect evaporative cooling technology: An updated review," Renewable and Sustainable Energy Reviews, Elsevier, vol. 145(C).
    5. Xu, Peng & Ma, Xiaoli & Zhao, Xudong & Fancey, Kevin, 2017. "Experimental investigation of a super performance dew point air cooler," Applied Energy, Elsevier, vol. 203(C), pages 761-777.
    6. Chen, Yi & Yan, Huaxia & Yang, Hongxing, 2018. "Comparative study of on-off control and novel high-low control of regenerative indirect evaporative cooler (RIEC)," Applied Energy, Elsevier, vol. 225(C), pages 233-243.
    7. Lin, Jie & Bui, Duc Thuan & Wang, Ruzhu & Chua, Kian Jon, 2018. "On the fundamental heat and mass transfer analysis of the counter-flow dew point evaporative cooler," Applied Energy, Elsevier, vol. 217(C), pages 126-142.
    8. Cui, X. & Islam, M.R. & Mohan, B. & Chua, K.J., 2016. "Theoretical analysis of a liquid desiccant based indirect evaporative cooling system," Energy, Elsevier, vol. 95(C), pages 303-312.
    9. Anisimov, Sergey & Pandelidis, Demis & Jedlikowski, Andrzej & Polushkin, Vitaliy, 2014. "Performance investigation of a M (Maisotsenko)-cycle cross-flow heat exchanger used for indirect evaporative cooling," Energy, Elsevier, vol. 76(C), pages 593-606.
    10. Ham, Sang-Woo & Jeong, Jae-Weon, 2016. "DPHX (dew point evaporative heat exchanger): System design and performance analysis," Energy, Elsevier, vol. 101(C), pages 132-145.
    11. Chen, Yi & Yan, Huaxia & Luo, Yimo & Yang, Hongxing, 2019. "A proportional–integral (PI) law based variable speed technology for temperature control in indirect evaporative cooling system," Applied Energy, Elsevier, vol. 251(C), pages 1-1.
    12. Elsarrag, Esam & Igobo, Opubo N. & Alhorr, Yousef & Davies, Philip A., 2016. "Solar pond powered liquid desiccant evaporative cooling," Renewable and Sustainable Energy Reviews, Elsevier, vol. 58(C), pages 124-140.
    13. Duan, Zhiyin & Zhao, Xudong & Li, Junming, 2017. "Design, fabrication and performance evaluation of a compact regenerative evaporative cooler: Towards low energy cooling for buildings," Energy, Elsevier, vol. 140(P1), pages 506-519.
    14. Lin, J. & Thu, K. & Bui, T.D. & Wang, R.Z. & Ng, K.C. & Kumja, M. & Chua, K.J., 2016. "Unsteady-state analysis of a counter-flow dew point evaporative cooling system," Energy, Elsevier, vol. 113(C), pages 172-185.
    15. Cui, X. & Chua, K.J. & Yang, W.M., 2014. "Numerical simulation of a novel energy-efficient dew-point evaporative air cooler," Applied Energy, Elsevier, vol. 136(C), pages 979-988.
    16. Yang, Yifan & Cui, Gary & Lan, Christopher Q., 2019. "Developments in evaporative cooling and enhanced evaporative cooling - A review," Renewable and Sustainable Energy Reviews, Elsevier, vol. 113(C), pages 1-1.
    17. Kim, Hui-Jeong & Ham, Sang-Woo & Yoon, Dong-Seob & Jeong, Jae-Weon, 2017. "Cooling performance measurement of two cross-flow indirect evaporative coolers in general and regenerative operation modes," Applied Energy, Elsevier, vol. 195(C), pages 268-277.
    18. Baniyounes, Ali M. & Ghadi, Yazeed Yasin & Rasul, M.G. & Khan, M.M.K., 2013. "An overview of solar assisted air conditioning in Queensland's subtropical regions, Australia," Renewable and Sustainable Energy Reviews, Elsevier, vol. 26(C), pages 781-804.
    19. He, Suoying & Gurgenci, Hal & Guan, Zhiqiang & Huang, Xiang & Lucas, Manuel, 2015. "A review of wetted media with potential application in the pre-cooling of natural draft dry cooling towers," Renewable and Sustainable Energy Reviews, Elsevier, vol. 44(C), pages 407-422.
    20. Jradi, M. & Riffat, S., 2014. "Experimental and numerical investigation of a dew-point cooling system for thermal comfort in buildings," Applied Energy, Elsevier, vol. 132(C), pages 524-535.

    Corrections

    All material on this site has been provided by the respective publishers and authors. You can help correct errors and omissions. When requesting a correction, please mention this item's handle: RePEc:eee:appene:v:194:y:2017:i:c:p:440-453. See general information about how to correct material in RePEc.

    If you have authored this item and are not yet registered with RePEc, we encourage you to do it here. This allows to link your profile to this item. It also allows you to accept potential citations to this item that we are uncertain about.

    If CitEc recognized a bibliographic reference but did not link an item in RePEc to it, you can help with this form .

    If you know of missing items citing this one, you can help us creating those links by adding the relevant references in the same way as above, for each refering item. If you are a registered author of this item, you may also want to check the "citations" tab in your RePEc Author Service profile, as there may be some citations waiting for confirmation.

    For technical questions regarding this item, or to correct its authors, title, abstract, bibliographic or download information, contact: Catherine Liu (email available below). General contact details of provider: http://www.elsevier.com/wps/find/journaldescription.cws_home/405891/description#description .

    Please note that corrections may take a couple of weeks to filter through the various RePEc services.

    IDEAS is a RePEc service. RePEc uses bibliographic data supplied by the respective publishers.