IDEAS home Printed from https://ideas.repec.org/a/eee/appene/v104y2013icp207-219.html
   My bibliography  Save this article

Potential of air-side economizers for data center cooling: A case study for key Australian cities

Author

Listed:
  • Siriwardana, Jayantha
  • Jayasekara, Saliya
  • Halgamuge, Saman K.

Abstract

The provision of low cost cooling is challenging due to high energy costs and increasing heat dissipation volumes from data centers. In Australia, with the introduction of emissions trading scheme, the cost of energy with carbon origin is expected to increase. In order to reduce cooling costs, alternative low cost cooling methods for data centers are highly sought after. In this study, we investigated using air-side economizers to introduce outside air with desired supply air conditions, by exploiting the cool and dry Australian climate conditions. Our approach was based on analyzing the hourly temperature and humidity data gathered over past 12years for 20 weather monitoring stations across Australia representing all geographical regions and determining the potential of using air-side economizers for those locations. As the result, we demonstrated that there is a sizable potential for using air-side economizers in some states that could lead to significant savings on cooling costs to data center operators.

Suggested Citation

  • Siriwardana, Jayantha & Jayasekara, Saliya & Halgamuge, Saman K., 2013. "Potential of air-side economizers for data center cooling: A case study for key Australian cities," Applied Energy, Elsevier, vol. 104(C), pages 207-219.
  • Handle: RePEc:eee:appene:v:104:y:2013:i:c:p:207-219
    DOI: 10.1016/j.apenergy.2012.10.046
    as

    Download full text from publisher

    File URL: http://www.sciencedirect.com/science/article/pii/S0306261912007659
    Download Restriction: Full text for ScienceDirect subscribers only

    File URL: https://libkey.io/10.1016/j.apenergy.2012.10.046?utm_source=ideas
    LibKey link: if access is restricted and if your library uses this service, LibKey will redirect you to where you can use your library subscription to access this item
    ---><---

    As the access to this document is restricted, you may want to search for a different version of it.

    References listed on IDEAS

    as
    1. Bulut, Hüsamettin & Aktacir, Mehmet Azmi, 2011. "Determination of free cooling potential: A case study for Istanbul, Turkey," Applied Energy, Elsevier, vol. 88(3), pages 680-689, March.
    2. Kaniyal, Ashok A. & Nathan, Graham J. & Pincus, Jonathan J., 2012. "The potential role of data-centres in enabling investment in geothermal energy," Applied Energy, Elsevier, vol. 98(C), pages 458-466.
    3. Dai, Jun & Das, Diganta & Pecht, Michael, 2012. "Prognostics-based risk mitigation for telecom equipment under free air cooling conditions," Applied Energy, Elsevier, vol. 99(C), pages 423-429.
    Full references (including those not matched with items on IDEAS)

    Most related items

    These are the items that most often cite the same works as this one and are cited by the same works as this one.
    1. Habibi Khalaj, Ali & Scherer, Thomas & K. Halgamuge, Saman, 2016. "Energy, environmental and economical saving potential of data centers with various economizers across Australia," Applied Energy, Elsevier, vol. 183(C), pages 1528-1549.
    2. Dai, Jun & Das, Diganta & Ohadi, Michael & Pecht, Michael, 2013. "Reliability risk mitigation of free air cooling through prognostics and health management," Applied Energy, Elsevier, vol. 111(C), pages 104-112.
    3. Durand-Estebe, Baptiste & Le Bot, Cédric & Mancos, Jean Nicolas & Arquis, Eric, 2014. "Simulation of a temperature adaptive control strategy for an IWSE economizer in a data center," Applied Energy, Elsevier, vol. 134(C), pages 45-56.
    4. Kim, Donghun & Braun, James E., 2020. "Model predictive control for supervising multiple rooftop unit economizers to fully leverage free cooling energy resource," Applied Energy, Elsevier, vol. 275(C).
    5. Dai, Jun & Das, Diganta & Pecht, Michael, 2012. "Prognostics-based risk mitigation for telecom equipment under free air cooling conditions," Applied Energy, Elsevier, vol. 99(C), pages 423-429.
    6. Sun, Xiaoqin & Zhang, Quan & Medina, Mario A. & Liao, Shuguang, 2015. "Performance of a free-air cooling system for telecommunications base stations using phase change materials (PCMs): In-situ tests," Applied Energy, Elsevier, vol. 147(C), pages 325-334.
    7. Xiaofei Huang & Junwei Yan & Xuan Zhou & Yixin Wu & Shichen Hu, 2023. "Cooling Technologies for Internet Data Center in China: Principle, Energy Efficiency, and Applications," Energies, MDPI, vol. 16(20), pages 1-31, October.
    8. Daniilidis, Alexandros & Saeid, Sanaz & Doonechaly, Nima Gholizadeh, 2021. "The fault plane as the main fluid pathway: Geothermal field development options under subsurface and operational uncertainty," Renewable Energy, Elsevier, vol. 171(C), pages 927-946.
    9. Tejero-González, Ana & Andrés-Chicote, Manuel & García-Ibáñez, Paola & Velasco-Gómez, Eloy & Rey-Martínez, Francisco Javier, 2016. "Assessing the applicability of passive cooling and heating techniques through climate factors: An overview," Renewable and Sustainable Energy Reviews, Elsevier, vol. 65(C), pages 727-742.
    10. Han, Zongwei & Xue, Da & Wei, Haotian & Ji, Qiang & Sun, Xiaoqing & Li, Xiuming, 2021. "Study on operation strategy of evaporative cooling composite air conditioning system in data center," Renewable Energy, Elsevier, vol. 177(C), pages 1147-1160.
    11. Barone, Giovanni & Buonomano, Annamaria & Giuzio, Giovanni Francesco & Palombo, Adolfo, 2023. "Towards zero energy infrastructure buildings: optimal design of envelope and cooling system," Energy, Elsevier, vol. 279(C).
    12. Chenfei Liu & Stephen Sharples & Haniyeh Mohammadpourkarbasi, 2023. "A Review of Building Energy Retrofit Measures, Passive Design Strategies and Building Regulation for the Low Carbon Development of Existing Dwellings in the Hot Summer–Cold Winter Region of China," Energies, MDPI, vol. 16(10), pages 1-25, May.
    13. Habibi Khalaj, Ali & Halgamuge, Saman K., 2017. "A Review on efficient thermal management of air- and liquid-cooled data centers: From chip to the cooling system," Applied Energy, Elsevier, vol. 205(C), pages 1165-1188.
    14. Oró, Eduard & Depoorter, Victor & Garcia, Albert & Salom, Jaume, 2015. "Energy efficiency and renewable energy integration in data centres. Strategies and modelling review," Renewable and Sustainable Energy Reviews, Elsevier, vol. 42(C), pages 429-445.
    15. Han, Zongwei & Ji, Qiang & Wei, Haotian & Xue, Da & Sun, Xiaoqing & Zhang, Xueping & Li, Xiuming, 2020. "Simulation study on performance of data center air-conditioning system with novel evaporative condenser," Energy, Elsevier, vol. 210(C).
    16. Fiorentini, Massimo & Tartarini, Federico & Ledo Gomis, Laia & Daly, Daniel & Cooper, Paul, 2019. "Development of an enthalpy-based index to assess climatic potential for ventilative cooling of buildings: An Australian example," Applied Energy, Elsevier, vol. 251(C), pages 1-1.
    17. Petraglia, Antonio & Spagnuolo, Antonio & Vetromile, Carmela & D'Onofrio, Antonio & Lubritto, Carmine, 2015. "Heat flows and energetic behavior of a telecommunication radio base station," Energy, Elsevier, vol. 89(C), pages 75-83.
    18. Wang, Fu & Deng, Shuai & Zhao, Jun & Wang, Junyao & Sun, Taiwei & Yan, Jinyue, 2017. "Performance and economic assessments of integrating geothermal energy into coal-fired power plant with CO2 capture," Energy, Elsevier, vol. 119(C), pages 278-287.
    19. Goopyo Hong & Chul Kim & Jun Hong, 2020. "Energy Conservation Potential of Economizer Controls Using Optimal Outdoor Air Fraction Based on Field Study," Energies, MDPI, vol. 13(19), pages 1-19, September.
    20. Zhang, Hainan & Shao, Shuangquan & Xu, Hongbo & Zou, Huiming & Tian, Changqing, 2014. "Free cooling of data centers: A review," Renewable and Sustainable Energy Reviews, Elsevier, vol. 35(C), pages 171-182.

    Corrections

    All material on this site has been provided by the respective publishers and authors. You can help correct errors and omissions. When requesting a correction, please mention this item's handle: RePEc:eee:appene:v:104:y:2013:i:c:p:207-219. See general information about how to correct material in RePEc.

    If you have authored this item and are not yet registered with RePEc, we encourage you to do it here. This allows to link your profile to this item. It also allows you to accept potential citations to this item that we are uncertain about.

    If CitEc recognized a bibliographic reference but did not link an item in RePEc to it, you can help with this form .

    If you know of missing items citing this one, you can help us creating those links by adding the relevant references in the same way as above, for each refering item. If you are a registered author of this item, you may also want to check the "citations" tab in your RePEc Author Service profile, as there may be some citations waiting for confirmation.

    For technical questions regarding this item, or to correct its authors, title, abstract, bibliographic or download information, contact: Catherine Liu (email available below). General contact details of provider: http://www.elsevier.com/wps/find/journaldescription.cws_home/405891/description#description .

    Please note that corrections may take a couple of weeks to filter through the various RePEc services.

    IDEAS is a RePEc service. RePEc uses bibliographic data supplied by the respective publishers.