IDEAS home Printed from https://ideas.repec.org/a/gam/jeners/v8y2015i1p656-681d44956.html
   My bibliography  Save this article

Mechanism Analysis and Experimental Validation of Employing Superconducting Magnetic Energy Storage to Enhance Power System Stability

Author

Listed:
  • Xiaohan Shi

    (State Key Laboratory of Advanced Electromagnetic Engineering and Technology, Huazhong University of Science and Technology, Wuhan 430074, China)

  • Shaorong Wang

    (State Key Laboratory of Advanced Electromagnetic Engineering and Technology, Huazhong University of Science and Technology, Wuhan 430074, China)

  • Wei Yao

    (State Key Laboratory of Advanced Electromagnetic Engineering and Technology, Huazhong University of Science and Technology, Wuhan 430074, China)

  • Asad Waqar

    (State Key Laboratory of Advanced Electromagnetic Engineering and Technology, Huazhong University of Science and Technology, Wuhan 430074, China)

  • Wenping Zuo

    (State Key Laboratory of Advanced Electromagnetic Engineering and Technology, Huazhong University of Science and Technology, Wuhan 430074, China)

  • Yuejin Tang

    (State Key Laboratory of Advanced Electromagnetic Engineering and Technology, Huazhong University of Science and Technology, Wuhan 430074, China)

Abstract

This paper investigates the mechanism analysis and the experimental validation of employing superconducting magnetic energy storage (SMES) to enhance power system stability. The models of the SMES device and the single-machine infinite-bus (SMIB) system with SMES are deduced. Based on the model of the SMIB system with SMES, the action mechanism of SMES on a generator is analyzed. The analysis takes the impact of SMES location and the system operating point into consideration, as well. Based on the mechanism analysis, the P -controller and Q -controller are designed utilizing the phase compensation method to improve the damping of the SMIB system. The influence of factors, such as SMES location, transmission system reactance, the dynamic characteristics of SMES and the system operating point, on the damping improvement of SMES, is investigated through root locus analysis. The simulation results of the SMIB test system verify the analysis conclusions and controller design method. The laboratory results of the 150-kJ/100-kW high-temperature SMES (HT-SMES) device validate that the SMES device can effectively enhance the damping, as well as the transient stability of the power system.

Suggested Citation

  • Xiaohan Shi & Shaorong Wang & Wei Yao & Asad Waqar & Wenping Zuo & Yuejin Tang, 2015. "Mechanism Analysis and Experimental Validation of Employing Superconducting Magnetic Energy Storage to Enhance Power System Stability," Energies, MDPI, vol. 8(1), pages 1-26, January.
  • Handle: RePEc:gam:jeners:v:8:y:2015:i:1:p:656-681:d:44956
    as

    Download full text from publisher

    File URL: https://www.mdpi.com/1996-1073/8/1/656/pdf
    Download Restriction: no

    File URL: https://www.mdpi.com/1996-1073/8/1/656/
    Download Restriction: no
    ---><---

    References listed on IDEAS

    as
    1. Ana Rodríguez & Francisco Huerta & Emilio J. Bueno & Francisco J. Rodríguez, 2013. "Analysis and Performance Comparison of Different Power Conditioning Systems for SMES-Based Energy Systems in Wind Turbines," Energies, MDPI, vol. 6(3), pages 1-27, March.
    2. Ning Zhang & Wei Gu & Haojun Yu & Wei Liu, 2013. "Application of Coordinated SOFC and SMES Robust Control for Stabilizing Tie-Line Power," Energies, MDPI, vol. 6(4), pages 1-16, April.
    Full references (including those not matched with items on IDEAS)

    Citations

    Citations are extracted by the CitEc Project, subscribe to its RSS feed for this item.
    as


    Cited by:

    1. Ziquan Liu & Wei Yao & Jinyu Wen, 2017. "Enhancement of Power System Stability Using a Novel Power System Stabilizer with Large Critical Gain," Energies, MDPI, vol. 10(4), pages 1-15, April.
    2. Lei Chen & Hongkun Chen & Jun Yang & Yanjuan Yu & Kaiwei Zhen & Yang Liu & Li Ren, 2017. "Coordinated Control of Superconducting Fault Current Limiter and Superconducting Magnetic Energy Storage for Transient Performance Enhancement of Grid-Connected Photovoltaic Generation System," Energies, MDPI, vol. 10(1), pages 1-23, January.

    Most related items

    These are the items that most often cite the same works as this one and are cited by the same works as this one.
    1. Lei Chen & Hongkun Chen & Jun Yang & Yanjuan Yu & Kaiwei Zhen & Yang Liu & Li Ren, 2017. "Coordinated Control of Superconducting Fault Current Limiter and Superconducting Magnetic Energy Storage for Transient Performance Enhancement of Grid-Connected Photovoltaic Generation System," Energies, MDPI, vol. 10(1), pages 1-23, January.
    2. Yanjuan Yu & Hongkun Chen & Lei Chen, 2018. "Comparative Study of Electric Energy Storages and Thermal Energy Auxiliaries for Improving Wind Power Integration in the Cogeneration System," Energies, MDPI, vol. 11(2), pages 1-16, January.
    3. Jianfei Zhao & Minqi Hua & Tingzhang Liu & Tao Yu, 2018. "Study on Topology and Control Strategy of High-Precision and Wide-Range Hybrid Converter for Photovoltaic Cell Simulator," Energies, MDPI, vol. 12(1), pages 1-19, December.
    4. Mani Ashouri & Filipe Faria da Silva & Claus Leth Bak, 2019. "A Harmonic Based Pilot Protection Scheme for VSC-MTDC Grids with PWM Converters," Energies, MDPI, vol. 12(6), pages 1-16, March.
    5. Juanjo Ugartemendia & J. Xabier Ostolaza & Itziar Zubia, 2013. "Operating Point Optimization of a Hydrogen Fueled Hybrid Solid Oxide Fuel Cell-Steam Turbine (SOFC-ST) Plant," Energies, MDPI, vol. 6(10), pages 1-23, September.
    6. Mingchao Xia & Xiaoliang Li, 2013. "Design and Implementation of a High Quality Power Supply Scheme for Distributed Generation in a Micro-Grid," Energies, MDPI, vol. 6(9), pages 1-21, September.
    7. Long-Yi Chang & Hung-Cheng Chen, 2014. "Linearization and Input-Output Decoupling for Nonlinear Control of Proton Exchange Membrane Fuel Cells," Energies, MDPI, vol. 7(2), pages 1-16, January.
    8. Wilson Cesar Sant’Ana & Robson Bauwelz Gonzatti & Germano Lambert-Torres & Erik Leandro Bonaldi & Bruno Silva Torres & Pedro Andrade de Oliveira & Rondineli Rodrigues Pereira & Luiz Eduardo Borges-da-, 2019. "Development and 24 Hour Behavior Analysis of a Peak-Shaving Equipment with Battery Storage," Energies, MDPI, vol. 12(11), pages 1-22, May.

    Corrections

    All material on this site has been provided by the respective publishers and authors. You can help correct errors and omissions. When requesting a correction, please mention this item's handle: RePEc:gam:jeners:v:8:y:2015:i:1:p:656-681:d:44956. See general information about how to correct material in RePEc.

    If you have authored this item and are not yet registered with RePEc, we encourage you to do it here. This allows to link your profile to this item. It also allows you to accept potential citations to this item that we are uncertain about.

    If CitEc recognized a bibliographic reference but did not link an item in RePEc to it, you can help with this form .

    If you know of missing items citing this one, you can help us creating those links by adding the relevant references in the same way as above, for each refering item. If you are a registered author of this item, you may also want to check the "citations" tab in your RePEc Author Service profile, as there may be some citations waiting for confirmation.

    For technical questions regarding this item, or to correct its authors, title, abstract, bibliographic or download information, contact: MDPI Indexing Manager (email available below). General contact details of provider: https://www.mdpi.com .

    Please note that corrections may take a couple of weeks to filter through the various RePEc services.

    IDEAS is a RePEc service. RePEc uses bibliographic data supplied by the respective publishers.