Improving the Thermal Performance of Indirect Evaporative Cooling by Using a Wet Fabric Device on a Concrete Roof in Hot and Humid Climates
Author
Abstract
Suggested Citation
Download full text from publisher
References listed on IDEAS
- Tang, Runsheng & Etzion, Y., 2005. "Cooling performance of roof ponds with gunny bags floating on water surface as compared with a movable insulation," Renewable Energy, Elsevier, vol. 30(9), pages 1373-1385.
- Madi Kaboré & Emmanuel Bozonnet & Patrick Salagnac, 2020. "Building and Urban Cooling Performance Indexes of Wetted and Green Roofs—A Case Study under Current and Future Climates," Energies, MDPI, vol. 13(23), pages 1-16, November.
- Raeissi, Soona & Taheri, Mansour, 1996. "Cooling load reduction of buildings using passive roof options," Renewable Energy, Elsevier, vol. 7(3), pages 301-313.
- Majed Abuseif & Zhonghua Gou, 2018. "A Review of Roofing Methods: Construction Features, Heat Reduction, Payback Period and Climatic Responsiveness," Energies, MDPI, vol. 11(11), pages 1-22, November.
- Chen, Qun & Yang, Kangding & Wang, Moran & Pan, Ning & Guo, Zeng-Yuan, 2010. "A new approach to analysis and optimization of evaporative cooling system I: Theory," Energy, Elsevier, vol. 35(6), pages 2448-2454.
- Spanaki, Artemisia & Tsoutsos, Theocharis & Kolokotsa, Dionysia, 2011. "On the selection and design of the proper roof pond variant for passive cooling purposes," Renewable and Sustainable Energy Reviews, Elsevier, vol. 15(8), pages 3523-3533.
- Ascione, Fabrizio & De Masi, Rosa Francesca & Santamouris, Mattheos & Ruggiero, Silvia & Vanoli, Giuseppe Peter, 2018. "Experimental and numerical evaluations on the energy penalty of reflective roofs during the heating season for Mediterranean climate," Energy, Elsevier, vol. 144(C), pages 178-199.
- Spanaki, Artemisia & Kolokotsa, Dionysia & Tsoutsos, Theocharis & Zacharopoulos, Ilias, 2014. "Assessing the passive cooling effect of the ventilated pond protected with a reflecting layer," Applied Energy, Elsevier, vol. 123(C), pages 273-280.
- Pradeep Shakya & Gimson Ng & Xiaoli Zhou & Yew Wah Wong & Swapnil Dubey & Shunzhi Qian, 2021. "Thermal Comfort and Energy Analysis of a Hybrid Cooling System by Coupling Natural Ventilation with Radiant and Indirect Evaporative Cooling," Energies, MDPI, vol. 14(22), pages 1-19, November.
- Sharifi, Ayyoob & Yamagata, Yoshiki, 2015. "Roof ponds as passive heating and cooling systems: A systematic review," Applied Energy, Elsevier, vol. 160(C), pages 336-357.
Citations
Citations are extracted by the CitEc Project, subscribe to its RSS feed for this item.
Cited by:
- JoAnn Cassar & Charles Galdies & Elizabeth Muscat Azzopardi, 2023. "Sustainability of Traditional, Historical Roofs in the Mediterranean: A Rediscovered Opportunity for a Carbon Neutral Future," Sustainability, MDPI, vol. 15(17), pages 1-21, August.
Most related items
These are the items that most often cite the same works as this one and are cited by the same works as this one.- Sharifi, Ayyoob & Yamagata, Yoshiki, 2015. "Roof ponds as passive heating and cooling systems: A systematic review," Applied Energy, Elsevier, vol. 160(C), pages 336-357.
- Rafael Suárez & Rocío Escandón & Ramón López-Pérez & Ángel Luis León-Rodríguez & Tillmann Klein & Sacha Silvester, 2018. "Impact of Climate Change: Environmental Assessment of Passive Solutions in a Single-Family Home in Southern Spain," Sustainability, MDPI, vol. 10(8), pages 1-17, August.
- Goudarzi, Hossein & Mostafaeipour, Ali, 2017. "Energy saving evaluation of passive systems for residential buildings in hot and dry regions," Renewable and Sustainable Energy Reviews, Elsevier, vol. 68(P1), pages 432-446.
- Spanaki, Artemisia & Tsoutsos, Theocharis & Kolokotsa, Dionysia, 2011. "On the selection and design of the proper roof pond variant for passive cooling purposes," Renewable and Sustainable Energy Reviews, Elsevier, vol. 15(8), pages 3523-3533.
- Seong-Il Park & Taek-Hyoung Ryu & Ick-Chang Choi & Jung-Sup Um, 2019. "Evaluating the Operational Potential of LRV Signatures Derived from UAV Imagery in Performance Evaluation of Cool Roofs," Energies, MDPI, vol. 12(14), pages 1-14, July.
- Zhang, Kai & Zhao, Dongliang & Yin, Xiaobo & Yang, Ronggui & Tan, Gang, 2018. "Energy saving and economic analysis of a new hybrid radiative cooling system for single-family houses in the USA," Applied Energy, Elsevier, vol. 224(C), pages 371-381.
- Renata Rapisarda & Francesco Nocera & Vincenzo Costanzo & Gaetano Sciuto & Rosa Caponetto, 2022. "Hydroponic Green Roof Systems as an Alternative to Traditional Pond and Green Roofs: A Literature Review," Energies, MDPI, vol. 15(6), pages 1-27, March.
- Almodovar, José Manuel & La Roche, Pablo, 2019. "Roof ponds combined with a water-to-air heat exchanger as a passive cooling system: Experimental comparison of two system variants," Renewable Energy, Elsevier, vol. 141(C), pages 195-208.
- Spanaki, Artemisia & Kolokotsa, Dionysia & Tsoutsos, Theocharis & Zacharopoulos, Ilias, 2014. "Assessing the passive cooling effect of the ventilated pond protected with a reflecting layer," Applied Energy, Elsevier, vol. 123(C), pages 273-280.
- Wenxiao Chu & Maria Vicidomini & Francesco Calise & Neven Duić & Poul Alborg Østergaard & Qiuwang Wang & Maria da Graça Carvalho, 2022. "Recent Advances in Low-Carbon and Sustainable, Efficient Technology: Strategies and Applications," Energies, MDPI, vol. 15(8), pages 1-30, April.
- Bin Li & Weihong Guo & Xiao Liu & Yuqing Zhang & Peter John Russell & Marc Aurel Schnabel, 2021. "Sustainable Passive Design for Building Performance of Healthy Built Environment in the Lingnan Area," Sustainability, MDPI, vol. 13(16), pages 1-22, August.
- Xu, Mingtian, 2012. "Variational principles in terms of entransy for heat transfer," Energy, Elsevier, vol. 44(1), pages 973-977.
- Yu Zhai & Xu Zhao & Zhifeng Dong, 2022. "Research on Performance Optimization of Gravity Heat Pipe for Mine Return Air," Energies, MDPI, vol. 15(22), pages 1-14, November.
- Zhan, Changhong & Duan, Zhiyin & Zhao, Xudong & Smith, Stefan & Jin, Hong & Riffat, Saffa, 2011. "Comparative study of the performance of the M-cycle counter-flow and cross-flow heat exchangers for indirect evaporative cooling – Paving the path toward sustainable cooling of buildings," Energy, Elsevier, vol. 36(12), pages 6790-6805.
- Guo, Jiangfeng & Huai, Xiulan, 2012. "Optimization design of recuperator in a chemical heat pump system based on entransy dissipation theory," Energy, Elsevier, vol. 41(1), pages 335-343.
- Duan, Zhiyin & Zhan, Changhong & Zhang, Xingxing & Mustafa, Mahmud & Zhao, Xudong & Alimohammadisagvand, Behrang & Hasan, Ala, 2012. "Indirect evaporative cooling: Past, present and future potentials," Renewable and Sustainable Energy Reviews, Elsevier, vol. 16(9), pages 6823-6850.
- Ramkishore Singh & Dharam Buddhi & Nikolai Ivanovich Vatin & Chander Prakash & Saurav Dixit & Gurbir Singh Khera & Sergei A. Solovev & Svetlana B. Ilyashenko & Vinod John, 2022. "Life Cycle Saving Analysis of an Earth-Coupled Building without and with Roof Evaporative Cooling for Energy Efficient Potato Storage Application," Energies, MDPI, vol. 15(11), pages 1-18, June.
- Zeynab Emdadi & Nilofar Asim & Mohd Ambar Yarmo & Roslinda Shamsudin & Masita Mohammad & Kamaruzaman Sopian, 2016. "Green Material Prospects for Passive Evaporative Cooling Systems: Geopolymers," Energies, MDPI, vol. 9(8), pages 1-19, July.
- Ahmed Alyahya & Nawari O. Nawari, 2018. "Towards Net-Zero Energy in Hot-Dry Regions: Building Envelope Design Strategies for Single-Family Homes," Journal of Sustainable Development, Canadian Center of Science and Education, vol. 11(3), pages 1-45, May.
- Chan, Lok Shun, 2023. "Numerical study on the thermal performance of water flow window fed with air-conditioning condensate," Energy, Elsevier, vol. 263(PB).
More about this item
Keywords
roof pond; passive cooling; wet fabric; experimental testing; indoor thermal performance;All these keywords.
Statistics
Access and download statisticsCorrections
All material on this site has been provided by the respective publishers and authors. You can help correct errors and omissions. When requesting a correction, please mention this item's handle: RePEc:gam:jeners:v:15:y:2022:i:6:p:2213-:d:773774. See general information about how to correct material in RePEc.
If you have authored this item and are not yet registered with RePEc, we encourage you to do it here. This allows to link your profile to this item. It also allows you to accept potential citations to this item that we are uncertain about.
If CitEc recognized a bibliographic reference but did not link an item in RePEc to it, you can help with this form .
If you know of missing items citing this one, you can help us creating those links by adding the relevant references in the same way as above, for each refering item. If you are a registered author of this item, you may also want to check the "citations" tab in your RePEc Author Service profile, as there may be some citations waiting for confirmation.
For technical questions regarding this item, or to correct its authors, title, abstract, bibliographic or download information, contact: MDPI Indexing Manager (email available below). General contact details of provider: https://www.mdpi.com .
Please note that corrections may take a couple of weeks to filter through the various RePEc services.