IDEAS home Printed from https://ideas.repec.org/a/gam/jeners/v11y2018i8p2077-d162911.html
   My bibliography  Save this article

A Numerical Investigation of Frost Growth on Cold Surfaces Based on the Lattice Boltzmann Method

Author

Listed:
  • Jianying Gong

    (MOE Key Laboratory of Thermo-Fluid Science and Engineering, School of Energy and Power Engineering, Xi’an Jiaotong University, Xi’an 710049, China)

  • Jianqiang Hou

    (MOE Key Laboratory of Thermo-Fluid Science and Engineering, School of Energy and Power Engineering, Xi’an Jiaotong University, Xi’an 710049, China)

  • Jinjuan Sun

    (School of Mechatronic Engineering, Xi’an Technological University, Xi’an 710021, China)

  • Guojun Li

    (MOE Key Laboratory of Thermo-Fluid Science and Engineering, School of Energy and Power Engineering, Xi’an Jiaotong University, Xi’an 710049, China)

  • Tieyu Gao

    (Department of Thermal Power Engineering, School of Energy and Power Engineering, Xi’an Jiaotong University, Xi’an 710049, China)

Abstract

A numerical investigation of frost growth on a cold flat surface was presented based on two-dimensional Lattice Boltzmann model. This model has been validated to have less prediction error by past experiments. According to the results, it is shown that average frost density appears different at an increasing rate at different frosting stages. In addition, cold surface temperature has great influence on frost growth parameters such as frost crystal deposition mass, frost deposition rate, and frost crystal volume fraction. It was found that the frost crystal deposition mass, frost crystal volume, and the deposition rate first increase rapidly, then gradually slow down, finally remaining unchanged while the cold surface temperature decreases. The further away from the cold surface, the more sparser the frost layer structure becomes due to the smaller frost crystal volume fraction.

Suggested Citation

  • Jianying Gong & Jianqiang Hou & Jinjuan Sun & Guojun Li & Tieyu Gao, 2018. "A Numerical Investigation of Frost Growth on Cold Surfaces Based on the Lattice Boltzmann Method," Energies, MDPI, vol. 11(8), pages 1-13, August.
  • Handle: RePEc:gam:jeners:v:11:y:2018:i:8:p:2077-:d:162911
    as

    Download full text from publisher

    File URL: https://www.mdpi.com/1996-1073/11/8/2077/pdf
    Download Restriction: no

    File URL: https://www.mdpi.com/1996-1073/11/8/2077/
    Download Restriction: no
    ---><---

    References listed on IDEAS

    as
    1. Xu, Bo & Han, Qing & Chen, Jiangping & Li, Feng & Wang, Nianjie & Li, Dong & Pan, Xiaoyong, 2013. "Experimental investigation of frost and defrost performance of microchannel heat exchangers for heat pump systems," Applied Energy, Elsevier, vol. 103(C), pages 180-188.
    2. Moo-Yeon Lee & Yongchan Kim & Dong-Yeon Lee, 2012. "Experimental Study on Frost Height of Round Plate Fin-Tube Heat Exchangers for Mobile Heat Pumps," Energies, MDPI, vol. 5(9), pages 1-13, September.
    Full references (including those not matched with items on IDEAS)

    Most related items

    These are the items that most often cite the same works as this one and are cited by the same works as this one.
    1. Ziqi Zhang & Wanyong Li & Junye Shi & Jiangping Chen, 2016. "A Study on Electric Vehicle Heat Pump Systems in Cold Climates," Energies, MDPI, vol. 9(11), pages 1-11, October.
    2. Chen, Siliang & Chen, Kang & Zhu, Xu & Jin, Xinqiao & Du, Zhimin, 2022. "Deep learning-based image recognition method for on-demand defrosting control to save energy in commercial energy systems," Applied Energy, Elsevier, vol. 324(C).
    3. Xu, Wei & Liu, Changping & Li, Angui & Li, Ji & Qiao, Biao, 2020. "Feasibility and performance study on hybrid air source heat pump system for ultra-low energy building in severe cold region of China," Renewable Energy, Elsevier, vol. 146(C), pages 2124-2133.
    4. Qinghong Peng & Qungui Du, 2016. "Progress in Heat Pump Air Conditioning Systems for Electric Vehicles—A Review," Energies, MDPI, vol. 9(4), pages 1-17, March.
    5. Ali Sadeghianjahromi & Saeid Kheradmand & Hossain Nemati & Jane-Sunn Liaw & Chi-Chuan Wang, 2018. "Compound Heat Transfer Enhancement of Wavy Fin-and-Tube Heat Exchangers through Boundary Layer Restarting and Swirled Flow," Energies, MDPI, vol. 11(8), pages 1-19, July.
    6. Ahn, Jae Hwan & Kim, Hoon & Jeon, Yongseok & Kwon, Ki Hyun, 2022. "Performance characteristics of mobile cooling system utilizing ice thermal energy storage with direct contact discharging for a refrigerated truck," Applied Energy, Elsevier, vol. 308(C).
    7. Kim, Min-Hwan & Lee, Kwan-Soo, 2015. "Determination method of defrosting start-time based on temperature measurements," Applied Energy, Elsevier, vol. 146(C), pages 263-269.
    8. Mustansar Hayat Saggu & Nadeem Ahmed Sheikh & Usama Muhammad Niazi & Muhammad Irfan & Adam Glowacz, 2020. "Predicting the Structural Reliability of LNG Processing Plate-Fin Heat Exchanger for Energy Conservation," Energies, MDPI, vol. 13(9), pages 1-22, May.
    9. Jingang Yang & Yaohua Zhao & Aoxue Chen & Zhenhua Quan, 2019. "Thermal Performance of a Low-Temperature Heat Exchanger Using a Micro Heat Pipe Array," Energies, MDPI, vol. 12(4), pages 1-16, February.
    10. Dixit, Tisha & Ghosh, Indranil, 2015. "Review of micro- and mini-channel heat sinks and heat exchangers for single phase fluids," Renewable and Sustainable Energy Reviews, Elsevier, vol. 41(C), pages 1298-1311.
    11. Huang, Wenzhu & Ji, Jie & Xu, Ning & Li, Guiqiang, 2016. "Frosting characteristics and heating performance of a direct-expansion solar-assisted heat pump for space heating under frosting conditions," Applied Energy, Elsevier, vol. 171(C), pages 656-666.
    12. Ramadan, M. & Khaled, M. & El Hage, H. & Harambat, F. & Peerhossaini, H., 2016. "Effect of air temperature non-uniformity on water–air heat exchanger thermal performance – Toward innovative control approach for energy consumption reduction," Applied Energy, Elsevier, vol. 173(C), pages 481-493.
    13. Li, Zhaoyang & Wang, Wei & Sun, Yuying & Wang, Shiquan & Deng, Shiming & Lin, Yao, 2021. "Applying image recognition to frost built-up detection in air source heat pumps," Energy, Elsevier, vol. 233(C).
    14. Xiong, Tong & Chen, Qi & Xu, Shijie & Liu, Guoqiang & Gao, Qiang & Yan, Gang, 2024. "A new defrosting model for microchannel heat exchanger heat pump system considering the effects of drainage and water retention," Energy, Elsevier, vol. 289(C).

    Corrections

    All material on this site has been provided by the respective publishers and authors. You can help correct errors and omissions. When requesting a correction, please mention this item's handle: RePEc:gam:jeners:v:11:y:2018:i:8:p:2077-:d:162911. See general information about how to correct material in RePEc.

    If you have authored this item and are not yet registered with RePEc, we encourage you to do it here. This allows to link your profile to this item. It also allows you to accept potential citations to this item that we are uncertain about.

    If CitEc recognized a bibliographic reference but did not link an item in RePEc to it, you can help with this form .

    If you know of missing items citing this one, you can help us creating those links by adding the relevant references in the same way as above, for each refering item. If you are a registered author of this item, you may also want to check the "citations" tab in your RePEc Author Service profile, as there may be some citations waiting for confirmation.

    For technical questions regarding this item, or to correct its authors, title, abstract, bibliographic or download information, contact: MDPI Indexing Manager (email available below). General contact details of provider: https://www.mdpi.com .

    Please note that corrections may take a couple of weeks to filter through the various RePEc services.

    IDEAS is a RePEc service. RePEc uses bibliographic data supplied by the respective publishers.