The Effect of a Vertical Electric Field on the Surface Flashover Characteristics of a Bushing Model

Author

Listed:
  • Mingxi Zhu

    (Laboratory of Advanced Technology of Electrical Engineering and Energy, Graduate School at Shenzhen, Tsinghua University, Shenzhen 518055, Guangdong, China)

  • Liming Wang

    (Laboratory of Advanced Technology of Electrical Engineering and Energy, Graduate School at Shenzhen, Tsinghua University, Shenzhen 518055, Guangdong, China)

  • Fanghui Yin

    (Laboratory of Advanced Technology of Electrical Engineering and Energy, Graduate School at Shenzhen, Tsinghua University, Shenzhen 518055, Guangdong, China)

  • Masoud Farzaneh

    (Applied Science, Université du Québec à Chicoutimi (UQAC), 555 Boulevard de l’Université, Chicoutimi, QC G7H 2B1, Canada)

  • Hongwei Mei

    (Laboratory of Advanced Technology of Electrical Engineering and Energy, Graduate School at Shenzhen, Tsinghua University, Shenzhen 518055, Guangdong, China)

  • Lu Wen

    (Laboratory of Advanced Technology of Electrical Engineering and Energy, Graduate School at Shenzhen, Tsinghua University, Shenzhen 518055, Guangdong, China)

Abstract

High-voltage bushings play a crucial role in energy conveyance. Their specialized electric structure makes the bushing more vulnerable to surface discharge. However, the influence of a vertical electric field on the surface flashover of bushing structures remains unclear. To investigate this mechanism, four simplified bushing samples were built and the influence of pollution, leakage length, and the electric field component vertical to the dielectric surface on flashover properties of the bushing samples were tested. It was found that the surface pollution level was the decisive factor that influenced flashover voltage. When the leakage length and form factor were the same, the pollution flashover of the bushing structure was lower than that of the post structure. It was also found that increasing the leakage length was not very effective in improving the flashover voltage of bushings when the equivalent salt deposit density (ESDD) was high. No obvious correlation was found between pollution flashover voltage and electric field stress. Furthermore, the uneven wetting flashover performance of the bushings was tested. Under this condition, the flashover voltage decreased with an increase of the electric field component vertical to the dielectric surface. In addition, the electric field distribution of the samples was calculated and the results were in accordance with the experimental results.

Suggested Citation

  • Mingxi Zhu & Liming Wang & Fanghui Yin & Masoud Farzaneh & Hongwei Mei & Lu Wen, 2018. "The Effect of a Vertical Electric Field on the Surface Flashover Characteristics of a Bushing Model," Energies, MDPI, vol. 11(6), pages 1-14, June.
  • Handle: RePEc:gam:jeners:v:11:y:2018:i:6:p:1607-:d:153401
    as

    Download full text from publisher

    File URL: https://www.mdpi.com/1996-1073/11/6/1607/pdf
    Download Restriction: no

    File URL: https://www.mdpi.com/1996-1073/11/6/1607/
    Download Restriction: no
    ---><---

    References listed on IDEAS

    as
    1. Feng Yang & Lin Du & Lijun Yang & Chao Wei & Youyuan Wang & Liman Ran & Peng He, 2018. "A Parameterization Approach for the Dielectric Response Model of Oil Paper Insulation Using FDS Measurements," Energies, MDPI, vol. 11(3), pages 1-17, March.
    2. Bo Qi & Quanmin Dai & Chengrong Li & Zipeng Zeng & Mingli Fu & Ran Zhuo, 2018. "The Mechanism and Diagnosis of Insulation Deterioration Caused by Moisture Ingress into Oil-Impregnated Paper Bushing," Energies, MDPI, vol. 11(6), pages 1-12, June.
    3. Youyuan Wang & Kun Xiao & Bijun Chen & Yuanlong Li, 2015. "Study of the Impact of Initial Moisture Content in Oil Impregnated Insulation Paper on Thermal Aging Rate of Condenser Bushing," Energies, MDPI, vol. 8(12), pages 1-13, December.
    Full references (including those not matched with items on IDEAS)

    Citations

    Citations are extracted by the CitEc Project, subscribe to its RSS feed for this item.
    as


    Cited by:

    1. Hao Tang & Guangning Wu & Ming Chen & Jiang Deng & Xining Li, 2019. "Analysis and Disposal of Typical Breakdown Failure for Resin Impregnated Paper Bushing in the Valve Side of HVDC Converter Transformer," Energies, MDPI, vol. 12(22), pages 1-13, November.
    2. Ming Chen & Xuandong Liu & Chengjun Liang & Yi Zhao & Hao Tang, 2019. "Study on Surface Charge Accumulation Characteristics of Resin Impregnated Paper Wall Bushing Core Under Positive DC Voltage," Energies, MDPI, vol. 12(23), pages 1-14, November.

    Most related items

    These are the items that most often cite the same works as this one and are cited by the same works as this one.
    1. Krzysztof Walczak & Jaroslaw Gielniak, 2021. "Temperature Distribution in the Insulation System of Condenser-Type HV Bushing—Its Effect on Dielectric Response in the Frequency Domain," Energies, MDPI, vol. 14(13), pages 1-18, July.
    2. Zhonghuan Su & Longfu Luo & Jun Liu & Zhongxiang Li & Hu Luo & Haonan Bai, 2022. "The Study of VFTO Distribution in the Insulation System of IOCT Used in Traction Network," Energies, MDPI, vol. 15(2), pages 1-13, January.
    3. Pawel Zukowski & Konrad Kierczynski & Przemyslaw Rogalski & Vitalii Bondariev & Marek Zenker & Rafal Pajak & Marek Szrot & Pawel Molenda & Tomasz N. Koltunowicz, 2024. "Analysis of the Influence of Insulation Moisture during Long-Term Exploitation of Transformers on Their Reliability as Determined by Alternating Current Electrical Parameters," Energies, MDPI, vol. 17(8), pages 1-23, April.
    4. Issouf Fofana & Yazid Hadjadj, 2018. "Power Transformer Diagnostics, Monitoring and Design Features," Energies, MDPI, vol. 11(12), pages 1-5, November.
    5. Tomasz N. Kołtunowicz & Konrad Kierczynski & Pawel Okal & Aleksy Patryn & Miroslav Gutten, 2022. "Diagnostics on the Basis of the Frequency-Temperature Dependences of the Loss Angle Tangent of Heavily Moistured Oil-Impregnated Pressboard," Energies, MDPI, vol. 15(8), pages 1-14, April.
    6. Chenmeng Zhang & Kailin Zhao & Shijun Xie & Can Hu & Yu Zhang & Nanxi Jiang, 2021. "Research on the Time-Domain Dielectric Response of Multiple Impulse Voltage Aging Oil-Film Dielectrics," Energies, MDPI, vol. 14(7), pages 1-15, April.
    7. Giovanni Hernandez & Abner Ramirez, 2022. "Dielectric Response Model for Transformer Insulation Using Frequency Domain Spectroscopy and Vector Fitting," Energies, MDPI, vol. 15(7), pages 1-14, April.
    8. Pasquale Cambareri & Carlo de Falco & Luca Di Rienzo & Paolo Seri & Gian Carlo Montanari, 2021. "Simulation and Modelling of Transient Electric Fields in HVDC Insulation Systems Based on Polarization Current Measurements," Energies, MDPI, vol. 14(24), pages 1-12, December.
    9. Grzegorz Dombek & Zbigniew Nadolny & Piotr Przybylek & Radoslaw Lopatkiewicz & Agnieszka Marcinkowska & Lukasz Druzynski & Tomasz Boczar & Andrzej Tomczewski, 2020. "Effect of Moisture on the Thermal Conductivity of Cellulose and Aramid Paper Impregnated with Various Dielectric Liquids," Energies, MDPI, vol. 13(17), pages 1-17, August.
    10. Guoqiang Xia & Guangning Wu & Bo Gao & Haojie Yin & Feibao Yang, 2017. "A New Method for Evaluating Moisture Content and Aging Degree of Transformer Oil-Paper Insulation Based on Frequency Domain Spectroscopy," Energies, MDPI, vol. 10(8), pages 1-15, August.
    11. Jiansheng Li & Zhi Li & Judong Chen & Yifan Bie & Jun Jiang & Xiaoping Yang, 2021. "Oil Pressure Monitoring for Sealing Failure Detection and Diagnosis of Power Transformer Bushing," Energies, MDPI, vol. 14(23), pages 1-17, November.
    12. Jiacheng Xie & Ming Dong & Boning Yu & Yizhuo Hu & Kaige Yang & Changjie Xia, 2020. "Physical Model for Frequency Domain Spectroscopy of Oil–Paper Insulation in a Wide Temperature Range by a Novel Analysis Approach," Energies, MDPI, vol. 13(17), pages 1-17, September.
    13. Benhui Lai & Shichang Yang & Heng Zhang & Yiyi Zhang & Xianhao Fan & Jiefeng Liu, 2020. "Performance Assessment of Oil-Immersed Cellulose Insulator Materials Using Time–Domain Spectroscopy under Varying Temperature and Humidity Conditions," Energies, MDPI, vol. 13(17), pages 1-14, August.

    Corrections

    All material on this site has been provided by the respective publishers and authors. You can help correct errors and omissions. When requesting a correction, please mention this item's handle: RePEc:gam:jeners:v:11:y:2018:i:6:p:1607-:d:153401. See general information about how to correct material in RePEc.

    If you have authored this item and are not yet registered with RePEc, we encourage you to do it here. This allows to link your profile to this item. It also allows you to accept potential citations to this item that we are uncertain about.

    If CitEc recognized a bibliographic reference but did not link an item in RePEc to it, you can help with this form .

    If you know of missing items citing this one, you can help us creating those links by adding the relevant references in the same way as above, for each refering item. If you are a registered author of this item, you may also want to check the "citations" tab in your RePEc Author Service profile, as there may be some citations waiting for confirmation.

    For technical questions regarding this item, or to correct its authors, title, abstract, bibliographic or download information, contact: MDPI Indexing Manager (email available below). General contact details of provider: https://www.mdpi.com .

    Please note that corrections may take a couple of weeks to filter through the various RePEc services.

    IDEAS is a RePEc service. RePEc uses bibliographic data supplied by the respective publishers.