Abstract

A high luminance contrast between windows and surrounding surfaces can increase the risk of discomfort glare, which can diminish office workers’ satisfaction and productivity. Accordingly, it can lead to occupant interventions, such as drawing window blinds or increasing electric light levels, which are intended to enhance indoor visual comfort but counterproductively act to increase energy consumption. Increasing the luminance of the areas surrounding the windows using a supplementary lighting system, such as wall-washing with light emitting diode (LED) linear luminaires, could reduce discomfort glare arising from windowed walls. This paper reports on the results of a study in a typical office room in Brisbane, Australia. The outcomes of this study indicate that creating a luminance contrast of between 11:1 and 12:1 on the window wall in an office room with a 45% window-to-exterior-wall ratio using a supplementary LED system leads to improved subjective assessments of window appearance. The results suggest that such an enhancement could significantly reduce discomfort glare from windows, as well as diminishing the likelihood of the users intending to turn on the ceiling lights or to move the blinds.

Suggested Citation

  • Mehdi Amirkhani & Veronica Garcia-Hansen & Gillian Isoardi & Alicia Allan, 2017. "An Energy Efficient Lighting Design Strategy to Enhance Visual Comfort in Offices with Windows," Energies, MDPI, vol. 10(8), pages 1-16, August.
  • Handle: RePEc:gam:jeners:v:10:y:2017:i:8:p:1126-:d:106643
    as

    Download full text from publisher

    File URL: https://www.mdpi.com/1996-1073/10/8/1126/pdf
    Download Restriction: no

    File URL: https://www.mdpi.com/1996-1073/10/8/1126/
    Download Restriction: no
    ---><---

    References listed on IDEAS

    as
    1. Hourani, May M. & Hammad, Rizeq N., 2012. "Impact of daylight quality on architectural space dynamics," Renewable and Sustainable Energy Reviews, Elsevier, vol. 16(6), pages 3579-3585.
    2. Alrubaih, M.S. & Zain, M.F.M. & Alghoul, M.A. & Ibrahim, N.L.N. & Shameri, M.A. & Elayeb, Omkalthum, 2013. "Research and development on aspects of daylighting fundamentals," Renewable and Sustainable Energy Reviews, Elsevier, vol. 21(C), pages 494-505.
    3. Ochoa, Carlos E. & Aries, Myriam B.C. & van Loenen, Evert J. & Hensen, Jan L.M., 2012. "Considerations on design optimization criteria for windows providing low energy consumption and high visual comfort," Applied Energy, Elsevier, vol. 95(C), pages 238-245.
    Full references (including those not matched with items on IDEAS)

    Citations

    Citations are extracted by the CitEc Project, subscribe to its RSS feed for this item.
    as


    Cited by:

    1. Alfonso Gago-Calderón & Manuel Jesús Hermoso-Orzáez & Jose Ramon De Andres-Diaz & Guillermo Redrado-Salvatierra, 2018. "Evaluation of Uniformity and Glare Improvement with Low Energy Efficiency Losses in Street Lighting LED Luminaires Using Laser-Sintered Polyamide-Based Diffuse Covers," Energies, MDPI, vol. 11(4), pages 1-17, April.
    2. Heangwoo Lee & Chang-ho Choi & Minki Sung, 2018. "Development of a Dimming Lighting Control System Using General Illumination and Location-Awareness Technology," Energies, MDPI, vol. 11(11), pages 1-19, November.
    3. Nuria Martín-Chivelet & Cecilia Guillén & Juan Francisco Trigo & José Herrero & Juan José Pérez & Faustino Chenlo, 2018. "Comparative Performance of Semi-Transparent PV Modules and Electrochromic Windows for Improving Energy Efficiency in Buildings," Energies, MDPI, vol. 11(6), pages 1-12, June.
    4. Patricia Aguilera-Benito & Carolina Piña-Ramírez & Sheila Varela-Lujan, 2021. "Experimental Analysis of Passive Strategies in Houses with Glass Façades for the Use of Natural Light," Sustainability, MDPI, vol. 13(15), pages 1-14, August.
    5. Yonggang Zhang & Yongwei Zhong & Yingda Gong & Lirong Zheng, 2018. "The Optimization of Visual Comfort and Energy Consumption Induced by Natural Light Based on PSO," Sustainability, MDPI, vol. 11(1), pages 1-11, December.

    Most related items

    These are the items that most often cite the same works as this one and are cited by the same works as this one.
    1. Pilechiha, Peiman & Mahdavinejad, Mohammadjavad & Pour Rahimian, Farzad & Carnemolla, Phillippa & Seyedzadeh, Saleh, 2020. "Multi-objective optimisation framework for designing office windows: quality of view, daylight and energy efficiency," Applied Energy, Elsevier, vol. 261(C).
    2. Gago, E.J. & Muneer, T. & Knez, M. & Köster, H., 2015. "Natural light controls and guides in buildings. Energy saving for electrical lighting, reduction of cooling load," Renewable and Sustainable Energy Reviews, Elsevier, vol. 41(C), pages 1-13.
    3. Ferenc Kalmár & Tünde Kalmár, 2020. "Thermal Comfort Aspects of Solar Gains during the Heating Season," Energies, MDPI, vol. 13(7), pages 1-15, April.
    4. Halil Alibaba, 2016. "Determination of Optimum Window to External Wall Ratio for Offices in a Hot and Humid Climate," Sustainability, MDPI, vol. 8(2), pages 1-21, February.
    5. Amir Faraji & Maria Rashidi & Fatemeh Rezaei & Payam Rahnamayiezekavat, 2023. "A Meta-Synthesis Review of Occupant Comfort Assessment in Buildings (2002–2022)," Sustainability, MDPI, vol. 15(5), pages 1-36, February.
    6. Michaela Detsi & Aris Manolitsis & Ioannis Atsonios & Ioannis Mandilaras & Maria Founti, 2020. "Energy Savings in an Office Building with High WWR Using Glazing Systems Combining Thermochromic and Electrochromic Layers," Energies, MDPI, vol. 13(11), pages 1-18, June.
    7. Seok-Hyun Kim & Hakgeun Jeong & Soo Cho, 2019. "A Study on Changes of Window Thermal Performance by Analysis of Physical Test Results in Korea," Energies, MDPI, vol. 12(20), pages 1-17, October.
    8. Das, Aparna & Paul, Saikat Kumar, 2015. "Artificial illumination during daytime in residential buildings: Factors, energy implications and future predictions," Applied Energy, Elsevier, vol. 158(C), pages 65-85.
    9. Allen Jong-Woei Whang & Tsai-Hsien Yang & Zhong-Hao Deng & Yi-Yung Chen & Wei-Chieh Tseng & Chun-Han Chou, 2019. "A Review of Daylighting System: For Prototype Systems Performance and Development," Energies, MDPI, vol. 12(15), pages 1-34, July.
    10. Lešnik, Maja & Kravanja, Stojan & Premrov, Miroslav & Žegarac Leskovar, Vesna, 2020. "Optimal design of timber-glass upgrade modules for vertical building extension from the viewpoints of energy efficiency and visual comfort," Applied Energy, Elsevier, vol. 270(C).
    11. Roberta Moschetti & Shabnam Homaei & Ellika Taveres-Cachat & Steinar Grynning, 2022. "Assessing Responsive Building Envelope Designs through Robustness-Based Multi-Criteria Decision Making in Zero-Emission Buildings," Energies, MDPI, vol. 15(4), pages 1-27, February.
    12. Sun, Yanyi & Liang, Runqi & Wu, Yupeng & Wilson, Robin & Rutherford, Peter, 2017. "Development of a comprehensive method to analyse glazing systems with Parallel Slat Transparent Insulation material (PS-TIM)," Applied Energy, Elsevier, vol. 205(C), pages 951-963.
    13. Sreelakshmi, Kavuthimadathil & Ramamurthy, K., 2022. "Review on fibre-optic-based daylight enhancement systems in buildings," Renewable and Sustainable Energy Reviews, Elsevier, vol. 163(C).
    14. Sana Sayadi & Abolfazl Hayati & Mazyar Salmanzadeh, 2021. "Optimization of Window-to-Wall Ratio for Buildings Located in Different Climates: An IDA-Indoor Climate and Energy Simulation Study," Energies, MDPI, vol. 14(7), pages 1-21, April.
    15. Ihara, Takeshi & Gao, Tao & Grynning, Steinar & Jelle, Bjørn Petter & Gustavsen, Arild, 2015. "Aerogel granulate glazing facades and their application potential from an energy saving perspective," Applied Energy, Elsevier, vol. 142(C), pages 179-191.
    16. Jiraphorn Mahawan & Atthakorn Thongtha, 2021. "Experimental Investigation of Illumination Performance of Hollow Light Pipe for Energy Consumption Reduction in Buildings," Energies, MDPI, vol. 14(2), pages 1-17, January.
    17. Capeluto, I. Guedi & Ochoa, Carlos E., 2014. "Simulation-based method to determine climatic energy strategies of an adaptable building retrofit façade system," Energy, Elsevier, vol. 76(C), pages 375-384.
    18. Favoino, Fabio & Fiorito, Francesco & Cannavale, Alessandro & Ranzi, Gianluca & Overend, Mauro, 2016. "Optimal control and performance of photovoltachromic switchable glazing for building integration in temperate climates," Applied Energy, Elsevier, vol. 178(C), pages 943-961.
    19. Ihara, Takeshi & Gustavsen, Arild & Jelle, Bjørn Petter, 2015. "Effect of facade components on energy efficiency in office buildings," Applied Energy, Elsevier, vol. 158(C), pages 422-432.
    20. Sadeghian, Omid & Mohammadi-Ivatloo, Behnam & Oshnoei, Arman & Aghaei, Jamshid, 2024. "Unveiling the potential of renewable energy and battery utilization in real-world public lighting systems: A review," Renewable and Sustainable Energy Reviews, Elsevier, vol. 192(C).

    Corrections

    All material on this site has been provided by the respective publishers and authors. You can help correct errors and omissions. When requesting a correction, please mention this item's handle: RePEc:gam:jeners:v:10:y:2017:i:8:p:1126-:d:106643. See general information about how to correct material in RePEc.

    If you have authored this item and are not yet registered with RePEc, we encourage you to do it here. This allows to link your profile to this item. It also allows you to accept potential citations to this item that we are uncertain about.

    If CitEc recognized a bibliographic reference but did not link an item in RePEc to it, you can help with this form .

    If you know of missing items citing this one, you can help us creating those links by adding the relevant references in the same way as above, for each refering item. If you are a registered author of this item, you may also want to check the "citations" tab in your RePEc Author Service profile, as there may be some citations waiting for confirmation.

    For technical questions regarding this item, or to correct its authors, title, abstract, bibliographic or download information, contact: MDPI Indexing Manager (email available below). General contact details of provider: https://www.mdpi.com .

    Please note that corrections may take a couple of weeks to filter through the various RePEc services.

    IDEAS is a RePEc service. RePEc uses bibliographic data supplied by the respective publishers.