IDEAS home Printed from https://ideas.repec.org/a/eee/renene/v32y2007i15p2461-2478.html
   My bibliography  Save this article

Ground heat exchangers—A review of systems, models and applications

Author

Listed:
  • Florides, Georgios
  • Kalogirou, Soteris

Abstract

The temperature at a certain depth in the ground remains nearly constant throughout the year and the ground capacitance is regarded as a passive means of heating and cooling of buildings. To exploit effectively the heat capacity of the ground, a heat-exchanger system has to be constructed. This is usually an array of buried pipes running along the length of a building, a nearby field or buried vertically into the ground. A circulating medium (water or air) is used in summer to extract heat from the hot environment of the building and dump it to the ground and vice versa in winter. A heat pump may also be coupled to the ground heat exchanger to increase its efficiency. In the literature, several calculation models are found for ground heat exchangers. The main input data are the geometrical characteristics of the system, the thermal characteristics of the ground, the thermal characteristics of the pipe and the undisturbed ground temperature during the operation of the system. During the first stages of the geothermal systems study, one-dimensional models were devised which were replaced by two-dimensional models during the 1990s and three-dimensional systems during recent years. The present models are further refined and can accommodate for any type of grid geometry that may give greater detail of the temperature variation around the pipes and in the ground. Monitoring systems have been set up to test various prototype constructions with satisfactory results.

Suggested Citation

  • Florides, Georgios & Kalogirou, Soteris, 2007. "Ground heat exchangers—A review of systems, models and applications," Renewable Energy, Elsevier, vol. 32(15), pages 2461-2478.
  • Handle: RePEc:eee:renene:v:32:y:2007:i:15:p:2461-2478
    DOI: 10.1016/j.renene.2006.12.014
    as

    Download full text from publisher

    File URL: http://www.sciencedirect.com/science/article/pii/S0960148107000092
    Download Restriction: Full text for ScienceDirect subscribers only

    File URL: https://libkey.io/10.1016/j.renene.2006.12.014?utm_source=ideas
    LibKey link: if access is restricted and if your library uses this service, LibKey will redirect you to where you can use your library subscription to access this item
    ---><---

    As the access to this document is restricted, you may want to search for a different version of it.

    References listed on IDEAS

    as
    1. Roth, P. & Georgiev, A. & Busso, A. & Barraza, E., 2004. "First in situ determination of ground and borehole thermal properties in Latin America," Renewable Energy, Elsevier, vol. 29(12), pages 1947-1963.
    2. Bojic, M. & Trifunovic, N. & Papadakis, G. & Kyritsis, S., 1997. "Numerical simulation, technical and economic evaluation of air-to-earth heat exchanger coupled to a building," Energy, Elsevier, vol. 22(12), pages 1151-1158.
    3. Kujawa, Tomasz & Nowak, Wladyslaw & Stachel, Aleksander A., 2003. "Heat-flow characteristics of one-hole and two-hole systems for winning geothermal heat," Applied Energy, Elsevier, vol. 74(1-2), pages 21-31, January.
    Full references (including those not matched with items on IDEAS)

    Most related items

    These are the items that most often cite the same works as this one and are cited by the same works as this one.
    1. Paul Christodoulides & Ana Vieira & Stanislav Lenart & João Maranha & Gregor Vidmar & Rumen Popov & Aleksandar Georgiev & Lazaros Aresti & Georgios Florides, 2020. "Reviewing the Modeling Aspects and Practices of Shallow Geothermal Energy Systems," Energies, MDPI, vol. 13(16), pages 1-45, August.
    2. Badescu, Viorel, 2007. "Simple and accurate model for the ground heat exchanger of a passive house," Renewable Energy, Elsevier, vol. 32(5), pages 845-855.
    3. Choi, Wonjun & Kikumoto, Hideki & Choudhary, Ruchi & Ooka, Ryozo, 2018. "Bayesian inference for thermal response test parameter estimation and uncertainty assessment," Applied Energy, Elsevier, vol. 209(C), pages 306-321.
    4. Choi, Wonjun & Ooka, Ryozo, 2015. "Interpretation of disturbed data in thermal response tests using the infinite line source model and numerical parameter estimation method," Applied Energy, Elsevier, vol. 148(C), pages 476-488.
    5. Li, Min & Zhang, Liwen & Liu, Gang, 2020. "Step-wise algorithm for estimating multi-parameter of the ground and geothermal heat exchangers from thermal response tests," Renewable Energy, Elsevier, vol. 150(C), pages 435-442.
    6. Cunha, R.P. & Bourne-Webb, P.J., 2022. "A critical review on the current knowledge of geothermal energy piles to sustainably climatize buildings," Renewable and Sustainable Energy Reviews, Elsevier, vol. 158(C).
    7. Zanchini, Enzo & Lazzari, Stefano & Priarone, Antonella, 2012. "Long-term performance of large borehole heat exchanger fields with unbalanced seasonal loads and groundwater flow," Energy, Elsevier, vol. 38(1), pages 66-77.
    8. Choi, Wonjun & Ooka, Ryozo, 2016. "Effect of disturbance on thermal response test, part 1: Development of disturbance analytical model, parametric study, and sensitivity analysis," Renewable Energy, Elsevier, vol. 85(C), pages 306-318.
    9. Ozgener, Leyla, 2011. "A review on the experimental and analytical analysis of earth to air heat exchanger (EAHE) systems in Turkey," Renewable and Sustainable Energy Reviews, Elsevier, vol. 15(9), pages 4483-4490.
    10. Nian, Yong-Le & Wang, Xiang-Yang & Xie, Kun & Cheng, Wen-Long, 2020. "Estimation of ground thermal properties for coaxial BHE through distributed thermal response test," Renewable Energy, Elsevier, vol. 152(C), pages 1209-1219.
    11. Soni, Suresh Kumar & Pandey, Mukesh & Bartaria, Vishvendra Nath, 2015. "Ground coupled heat exchangers: A review and applications," Renewable and Sustainable Energy Reviews, Elsevier, vol. 47(C), pages 83-92.
    12. Mihalakakou, Giouli & Souliotis, Manolis & Papadaki, Maria & Halkos, George & Paravantis, John & Makridis, Sofoklis & Papaefthimiou, Spiros, 2022. "Applications of earth-to-air heat exchangers: A holistic review," Renewable and Sustainable Energy Reviews, Elsevier, vol. 155(C).
    13. Peretti, Clara & Zarrella, Angelo & De Carli, Michele & Zecchin, Roberto, 2013. "The design and environmental evaluation of earth-to-air heat exchangers (EAHE). A literature review," Renewable and Sustainable Energy Reviews, Elsevier, vol. 28(C), pages 107-116.
    14. Dehkordi, S. Emad & Schincariol, Robert A. & Reitsma, Stanley, 2015. "Thermal performance of a tight borehole heat exchanger," Renewable Energy, Elsevier, vol. 83(C), pages 698-704.
    15. Choi, Wonjun & Ooka, Ryozo, 2016. "Effect of natural convection on thermal response test conducted in saturated porous formation: Comparison of gravel-backfilled and cement-grouted borehole heat exchangers," Renewable Energy, Elsevier, vol. 96(PA), pages 891-903.
    16. Tittelein, Pierre & Achard, Gilbert & Wurtz, Etienne, 2009. "Modelling earth-to-air heat exchanger behaviour with the convolutive response factors method," Applied Energy, Elsevier, vol. 86(9), pages 1683-1691, September.
    17. Zanchini, E. & Lazzari, S. & Priarone, A., 2010. "Improving the thermal performance of coaxial borehole heat exchangers," Energy, Elsevier, vol. 35(2), pages 657-666.
    18. Choi, Wonjun & Ooka, Ryozo, 2016. "Effect of disturbance on thermal response test, part 2: Numerical study of applicability and limitation of infinite line source model for interpretation under disturbance from outdoor environment," Renewable Energy, Elsevier, vol. 85(C), pages 1090-1105.
    19. Bisoniya, Trilok Singh & Kumar, Anil & Baredar, Prashant, 2013. "Experimental and analytical studies of earth–air heat exchanger (EAHE) systems in India: A review," Renewable and Sustainable Energy Reviews, Elsevier, vol. 19(C), pages 238-246.
    20. Jun, Liu & Xu, Zhang & Jun, Gao & Jie, Yang, 2009. "Evaluation of heat exchange rate of GHE in geothermal heat pump systems," Renewable Energy, Elsevier, vol. 34(12), pages 2898-2904.

    Corrections

    All material on this site has been provided by the respective publishers and authors. You can help correct errors and omissions. When requesting a correction, please mention this item's handle: RePEc:eee:renene:v:32:y:2007:i:15:p:2461-2478. See general information about how to correct material in RePEc.

    If you have authored this item and are not yet registered with RePEc, we encourage you to do it here. This allows to link your profile to this item. It also allows you to accept potential citations to this item that we are uncertain about.

    If CitEc recognized a bibliographic reference but did not link an item in RePEc to it, you can help with this form .

    If you know of missing items citing this one, you can help us creating those links by adding the relevant references in the same way as above, for each refering item. If you are a registered author of this item, you may also want to check the "citations" tab in your RePEc Author Service profile, as there may be some citations waiting for confirmation.

    For technical questions regarding this item, or to correct its authors, title, abstract, bibliographic or download information, contact: Catherine Liu (email available below). General contact details of provider: http://www.journals.elsevier.com/renewable-energy .

    Please note that corrections may take a couple of weeks to filter through the various RePEc services.

    IDEAS is a RePEc service. RePEc uses bibliographic data supplied by the respective publishers.