IDEAS home Printed from https://ideas.repec.org/a/eee/energy/v27y2002i4p391-404.html
   My bibliography  Save this article

The effects of improper refrigerant charge on the performance of a heat pump with an electronic expansion valve and capillary tube

Author

Listed:
  • Choi, J.M
  • Kim, Y.C

Abstract

For inverter heat pumps and multi-type heat pumps, conventional expansion devices such as capillary tubes, short tube orifices, and thermostatic expansion valves (TXVs) are being gradually replaced with electronic expansion valves (EEVs) because of the increasing focus on comfort and energy conservation. In this study, the effects of off-design refrigerant charge on the performance of a water-to-water heat pump are investigated by varying refrigerant charge amount from −20% to +20% of full charge in a steady state, cooling mode operation with expansion devices of capillary tube and EEV. The characteristics of the heat pump with an EEV are compared with those with a capillary tube. The capillary tube system is more sensitive to off-design charge as compared with the EEV system. Cooling capacity and COP of the EEV system show little dependence on refrigerant charge, while those are strongly dependent on outdoor conditions. In general, for a wide range of operating conditions the EEV system shows much higher performance as compared with the capillary tube system. The performance of the EEV system can be optimized by adjusting the EEV opening to maintain a constant superheat at all test conditions.

Suggested Citation

  • Choi, J.M & Kim, Y.C, 2002. "The effects of improper refrigerant charge on the performance of a heat pump with an electronic expansion valve and capillary tube," Energy, Elsevier, vol. 27(4), pages 391-404.
  • Handle: RePEc:eee:energy:v:27:y:2002:i:4:p:391-404
    DOI: 10.1016/S0360-5442(01)00093-7
    as

    Download full text from publisher

    File URL: http://www.sciencedirect.com/science/article/pii/S0360544201000937
    Download Restriction: Full text for ScienceDirect subscribers only

    File URL: https://libkey.io/10.1016/S0360-5442(01)00093-7?utm_source=ideas
    LibKey link: if access is restricted and if your library uses this service, LibKey will redirect you to where you can use your library subscription to access this item
    ---><---

    As the access to this document is restricted, you may want to search for a different version of it.

    Citations

    Citations are extracted by the CitEc Project, subscribe to its RSS feed for this item.
    as


    Cited by:

    1. Jun Kwon Hwang & Patrick Nzivugira Duhirwe & Geun Young Yun & Sukho Lee & Hyeongjoon Seo & Inhan Kim & Mat Santamouris, 2020. "A Novel Hybrid Deep Neural Network Model to Predict the Refrigerant Charge Amount of Heat Pumps," Sustainability, MDPI, vol. 12(7), pages 1-23, April.
    2. Park, Young Sung & Jeong, Ji Hwan & Ahn, Byoung Ha, 2014. "Heat pump control method based on direct measurement of evaporation pressure to improve energy efficiency and indoor air temperature stability at a low cooling load condition," Applied Energy, Elsevier, vol. 132(C), pages 99-107.
    3. Bolaji, B.O., 2010. "Experimental study of R152a and R32 to replace R134a in a domestic refrigerator," Energy, Elsevier, vol. 35(9), pages 3793-3798.
    4. Ze Zhang & Xiaojun Dong & Zheng Ren & Tianwei Lai & Yu Hou, 2017. "Influence of Refrigerant Charge Amount and EEV Opening on the Performance of a Transcritical CO 2 Heat Pump Water Heater," Energies, MDPI, vol. 10(10), pages 1-14, October.
    5. Belman-Flores, J.M. & Barroso-Maldonado, J.M. & Rodríguez-Muñoz, A.P. & Camacho-Vázquez, G., 2015. "Enhancements in domestic refrigeration, approaching a sustainable refrigerator – A review," Renewable and Sustainable Energy Reviews, Elsevier, vol. 51(C), pages 955-968.
    6. Qu, Minglu & Xia, Liang & Deng, Shiming & Jiang, Yiqiang, 2012. "An experimental investigation on reverse-cycle defrosting performance for an air source heat pump using an electronic expansion valve," Applied Energy, Elsevier, vol. 97(C), pages 327-333.
    7. Chae, Jung-Hoon & Choi, Jong Min, 2015. "Evaluation of the impacts of high stage refrigerant charge on cascade heat pump performance," Renewable Energy, Elsevier, vol. 79(C), pages 66-71.
    8. Kang Li & Jun Yu & Mingkang Liu & Dan Xu & Lin Su & Yidong Fang, 2020. "A Study of Optimal Refrigerant Charge Amount Determination for Air-Conditioning Heat Pump System in Electric Vehicles," Energies, MDPI, vol. 13(3), pages 1-18, February.

    More about this item

    Statistics

    Access and download statistics

    Corrections

    All material on this site has been provided by the respective publishers and authors. You can help correct errors and omissions. When requesting a correction, please mention this item's handle: RePEc:eee:energy:v:27:y:2002:i:4:p:391-404. See general information about how to correct material in RePEc.

    If you have authored this item and are not yet registered with RePEc, we encourage you to do it here. This allows to link your profile to this item. It also allows you to accept potential citations to this item that we are uncertain about.

    We have no bibliographic references for this item. You can help adding them by using this form .

    If you know of missing items citing this one, you can help us creating those links by adding the relevant references in the same way as above, for each refering item. If you are a registered author of this item, you may also want to check the "citations" tab in your RePEc Author Service profile, as there may be some citations waiting for confirmation.

    For technical questions regarding this item, or to correct its authors, title, abstract, bibliographic or download information, contact: Catherine Liu (email available below). General contact details of provider: http://www.journals.elsevier.com/energy .

    Please note that corrections may take a couple of weeks to filter through the various RePEc services.

    IDEAS is a RePEc service. RePEc uses bibliographic data supplied by the respective publishers.