IDEAS home Printed from https://ideas.repec.org/a/eee/energy/v112y2016icp179-187.html
   My bibliography  Save this article

Performance comparison between R410A and R32 multi-heat pumps with a sub-cooler vapor injection in the heating and cooling modes

Author

Listed:
  • Cho, Il Yong
  • Seo, HyeongJoon
  • Kim, Dongwoo
  • Kim, Yongchan

Abstract

The cooling and heating performances of R410A and R32 multi-heat pumps with a sub-cooler vapor injection (SCVI) were measured and compared with variations in the outdoor temperature, compressor speed, and injection ratio. Optimum injection ratios were determined to obtain maximum cooling and heating performances at a given operating condition. In the cooling mode with the optimum injection ratios, the R410A and R32 multi-heat pumps with vapor injection showed 2.1%–6.3% higher cooling capacity than those without vapor injection. In the heating mode, the R410A and R32 multi-heat pumps with vapor injection showed 7.5%–13.9% higher heating capacity than those without vapor injection, while showing 2.6%–7.0% and 1.1%–4.7% higher COPs, respectively. In addition, the SCVI cycle was more effective for improving the cooling and heating performances under extremely hot and cold weather conditions, respectively.

Suggested Citation

  • Cho, Il Yong & Seo, HyeongJoon & Kim, Dongwoo & Kim, Yongchan, 2016. "Performance comparison between R410A and R32 multi-heat pumps with a sub-cooler vapor injection in the heating and cooling modes," Energy, Elsevier, vol. 112(C), pages 179-187.
  • Handle: RePEc:eee:energy:v:112:y:2016:i:c:p:179-187
    DOI: 10.1016/j.energy.2016.06.069
    as

    Download full text from publisher

    File URL: http://www.sciencedirect.com/science/article/pii/S036054421630843X
    Download Restriction: Full text for ScienceDirect subscribers only

    File URL: https://libkey.io/10.1016/j.energy.2016.06.069?utm_source=ideas
    LibKey link: if access is restricted and if your library uses this service, LibKey will redirect you to where you can use your library subscription to access this item
    ---><---

    As the access to this document is restricted, you may want to search for a different version of it.

    References listed on IDEAS

    as
    1. Yang, Zhao & Wu, Xi, 2013. "Retrofits and options for the alternatives to HCFC-22," Energy, Elsevier, vol. 59(C), pages 1-21.
    2. Baek, Changhyun & Heo, Jaehyeok & Jung, Jongho & Cho, Honghyun & Kim, Yongchan, 2014. "Performance characteristics of a two-stage CO2 heat pump water heater adopting a sub-cooler vapor injection cycle at various operating conditions," Energy, Elsevier, vol. 77(C), pages 570-578.
    Full references (including those not matched with items on IDEAS)

    Citations

    Citations are extracted by the CitEc Project, subscribe to its RSS feed for this item.
    as


    Cited by:

    1. Jung, Jongho & Jeon, Yongseok & Cho, Wonhee & Kim, Yongchan, 2020. "Effects of injection-port angle and internal heat exchanger length in vapor injection heat pumps for electric vehicles," Energy, Elsevier, vol. 193(C).
    2. Kim, Dongwoo & Myeong, Seongryeol & Cha, Dowon & Kim, Yongchan, 2019. "Novel optimized operating strategies of two-phase injection heat pumps for achieving best performance with safe compression," Energy, Elsevier, vol. 187(C).
    3. López-Belchí, Alejandro & Illán-Gómez, Fernando, 2017. "Evaluation of a condenser based on mini-channels technology working with R410A and R32. Experimental data and performance estimate," Applied Energy, Elsevier, vol. 202(C), pages 112-124.
    4. Han, Xinxin & Zou, Huiming & Wu, Jiang & Tian, Changqing & Tang, Mingsheng & Huang, Guangyan, 2020. "Investigation on the heating performance of the heat pump with waste heat recovery for the electric bus," Renewable Energy, Elsevier, vol. 152(C), pages 835-848.
    5. Jeon, Yongseok & Jung, Jongho & Kim, Dongwoo & Kim, Sunjae & Kim, Yongchan, 2017. "Effects of ejector geometries on performance of ejector-expansion R410A air conditioner considering cooling seasonal performance factor," Applied Energy, Elsevier, vol. 205(C), pages 761-768.
    6. Kim, Dongwoo & Song, Kang Sub & Lim, Junyub & Kim, Yongchan, 2018. "Analysis of two-phase injection heat pump using artificial neural network considering APF and LCCP under various weather conditions," Energy, Elsevier, vol. 155(C), pages 117-127.
    7. Song, Zhiying & Ji, Jie & Zhang, Yuzhe & Cai, Jingyong, 2023. "Numerical exploration and experimental validation of a tri-generation heat pump system in cooling mode," Energy, Elsevier, vol. 273(C).
    8. Maeng, Heegyu & Kim, Jinyoung & Kwon, Soonbum & Kim, Yongchan, 2023. "Energy and environmental performance of vapor injection heat pumps using R134a, R152a, and R1234yf under various injection conditions," Energy, Elsevier, vol. 280(C).
    9. Yuan, Zhipeng & Liu, Qi & Luo, Baojun & Li, Zhenming & Fu, Jianqin & Chen, Jingwei, 2018. "Thermodynamic analysis of different oil flooded compression enhanced vapor injection cycles," Energy, Elsevier, vol. 154(C), pages 553-560.
    10. Shuxue, Xu & Yueyue, Wang & Jianhui, Niu & Guoyuan, Ma, 2020. "‘Coal-to-electricity’ project is ongoing in north China," Energy, Elsevier, vol. 191(C).
    11. Chung, Hyun Joon & Baek, Changhyun & Kang, Hoon & Kim, Dongwoo & Kim, Yongchan, 2018. "Performance evaluation of a gas injection CO2 heat pump according to operating parameters in extreme heating and cooling conditions," Energy, Elsevier, vol. 154(C), pages 337-345.
    12. Settino, Jessica & Sant, Tonio & Micallef, Christopher & Farrugia, Mario & Spiteri Staines, Cyril & Licari, John & Micallef, Alexander, 2018. "Overview of solar technologies for electricity, heating and cooling production," Renewable and Sustainable Energy Reviews, Elsevier, vol. 90(C), pages 892-909.
    13. Fan, Yi & Zhao, Xudong & Li, Jing & Li, Guiqiang & Myers, Steve & Cheng, Yuanda & Badiei, Ali & Yu, Min & Golizadeh Akhlaghi, Yousef & Shittu, Samson & Ma, Xiaoli, 2020. "Economic and environmental analysis of a novel rural house heating and cooling system using a solar-assisted vapour injection heat pump," Applied Energy, Elsevier, vol. 275(C).
    14. Hongzhi Liu & Katsunori Nagano & Takao Katsura & Yue Han, 2020. "Experimental Investigation on a Vapor Injection Heat Pump System with a Single-Stage Compressor," Energies, MDPI, vol. 13(12), pages 1-19, June.
    15. Wen, Qiangyu & Zhi, Ruiping & Wu, Yuting & Lei, Biao & Liu, Shanwei & Shen, Lili, 2020. "Performance optimization of a heat pump integrated with a single-screw refrigeration compressor with liquid refrigerant injection," Energy, Elsevier, vol. 207(C).
    16. Kim, Dongwoo & Lee, DongChan & Lee, Minwoo & Chung, Hyun Joon & Kim, Yongchan, 2021. "Energy performance evaluation of two-phase injection heat pump employing low-GWP refrigerant R32 under various outdoor conditions," Energy, Elsevier, vol. 214(C).
    17. Wei, Wenzhe & Ni, Long & Li, Shuyi & Wang, Wei & Yao, Yang & Xu, Laifu & Yang, Yahua, 2020. "A new frosting map of variable-frequency air source heat pump in severe cold region considering the variation of heating load," Renewable Energy, Elsevier, vol. 161(C), pages 184-199.
    18. Kim, Dongwoo & Chung, Hyun Joon & Jeon, Yongseok & Jang, Dong Soo & Kim, Yongchan, 2017. "Optimization of the injection-port geometries of a vapor injection scroll compressor based on SCOP under various climatic conditions," Energy, Elsevier, vol. 135(C), pages 442-454.

    Most related items

    These are the items that most often cite the same works as this one and are cited by the same works as this one.
    1. Jung, Jongho & Jeon, Yongseok & Cho, Wonhee & Kim, Yongchan, 2020. "Effects of injection-port angle and internal heat exchanger length in vapor injection heat pumps for electric vehicles," Energy, Elsevier, vol. 193(C).
    2. Feng, Biao & Yang, Zhao & Zhai, Rui, 2017. "Experimental research on the concentration characteristics of R32 and R161′ combustion product HF," Energy, Elsevier, vol. 125(C), pages 671-680.
    3. Wu, Xi & Xu, Shiming & Jiang, Mengnan, 2018. "Development of bubble absorption refrigeration technology: A review," Renewable and Sustainable Energy Reviews, Elsevier, vol. 82(P3), pages 3468-3482.
    4. El-Morsi, Mohamed, 2015. "Energy and exergy analysis of LPG (liquefied petroleum gas) as a drop in replacement for R134a in domestic refrigerators," Energy, Elsevier, vol. 86(C), pages 344-353.
    5. Abas, Naeem & Kalair, Ali Raza & Khan, Nasrullah & Haider, Aun & Saleem, Zahid & Saleem, Muhammad Shoaib, 2018. "Natural and synthetic refrigerants, global warming: A review," Renewable and Sustainable Energy Reviews, Elsevier, vol. 90(C), pages 557-569.
    6. Chung, Hyun Joon & Baek, Changhyun & Kang, Hoon & Kim, Dongwoo & Kim, Yongchan, 2018. "Performance evaluation of a gas injection CO2 heat pump according to operating parameters in extreme heating and cooling conditions," Energy, Elsevier, vol. 154(C), pages 337-345.
    7. Mota-Babiloni, Adrián & Belman-Flores, J.M. & Makhnatch, Pavel & Navarro-Esbrí, Joaquín & Barroso-Maldonado, J.M., 2018. "Experimental exergy analysis of R513A to replace R134a in a small capacity refrigeration system," Energy, Elsevier, vol. 162(C), pages 99-110.
    8. Kim, Dongwoo & Chung, Hyun Joon & Jeon, Yongseok & Jang, Dong Soo & Kim, Yongchan, 2017. "Optimization of the injection-port geometries of a vapor injection scroll compressor based on SCOP under various climatic conditions," Energy, Elsevier, vol. 135(C), pages 442-454.
    9. Mendoza-Miranda, J.M. & Mota-Babiloni, A. & Ramírez-Minguela, J.J. & Muñoz-Carpio, V.D. & Carrera-Rodríguez, M. & Navarro-Esbrí, J. & Salazar-Hernández, C., 2016. "Comparative evaluation of R1234yf, R1234ze(E) and R450A as alternatives to R134a in a variable speed reciprocating compressor," Energy, Elsevier, vol. 114(C), pages 753-766.
    10. Mohanraj, M. & Belyayev, Ye. & Jayaraj, S. & Kaltayev, A., 2018. "Research and developments on solar assisted compression heat pump systems – A comprehensive review (Part A: Modeling and modifications)," Renewable and Sustainable Energy Reviews, Elsevier, vol. 83(C), pages 90-123.
    11. Mohapatra, Alok Ku & Sanjay,, 2014. "Thermodynamic assessment of impact of inlet air cooling techniques on gas turbine and combined cycle performance," Energy, Elsevier, vol. 68(C), pages 191-203.
    12. Yang, Zhao & Wu, Xi & Tian, Tian, 2015. "Flammability of Trans-1, 3, 3, 3-tetrafluoroprop-1-ene and its binary blends," Energy, Elsevier, vol. 91(C), pages 386-392.
    13. Yulong Song & Haidan Wang & Feng Cao, 2020. "Investigation of the Impact Factors on the Optimal Intermediate Temperature in a Dual Transcritical CO 2 System with a Dedicated Transcritical CO 2 Subcooler," Energies, MDPI, vol. 13(2), pages 1-23, January.
    14. Henchoz, Samuel & Weber, Céline & Maréchal, François & Favrat, Daniel, 2015. "Performance and profitability perspectives of a CO2 based district energy network in Geneva's City Centre," Energy, Elsevier, vol. 85(C), pages 221-235.
    15. Zeng, Min-Qiang & Zheng, Qiu-Yun & Zhang, Xue-Lai & Mo, Fan-Yang & Zhang, Xin-Rong, 2022. "Thermodynamic analysis of a novel multi-target temperature transcritical CO2 ejector-expansion refrigeration cycle with vapor-injection," Energy, Elsevier, vol. 259(C).
    16. Kim, Dongwoo & Myeong, Seongryeol & Cha, Dowon & Kim, Yongchan, 2019. "Novel optimized operating strategies of two-phase injection heat pumps for achieving best performance with safe compression," Energy, Elsevier, vol. 187(C).
    17. Ge, T.S. & Weng, Z.C. & Huang, R. & Hu, B. & Eikevik, Trygve Magne & Dai, Y.J., 2023. "High temperature transcritical CO2 heat pump with optimized tube-in-tube heat exchanger," Energy, Elsevier, vol. 283(C).
    18. Jia, Jie & Lee, W.L., 2015. "Experimental study of the application of intermittently operated SEHRAC (storage-enhanced heat recovery room air-conditioner) in residential buildings in Hong Kong," Energy, Elsevier, vol. 83(C), pages 628-637.

    More about this item

    Keywords

    Vapor injection; Multi-heat pump; Injection ratio; R410A; R32;
    All these keywords.

    JEL classification:

    • R32 - Urban, Rural, Regional, Real Estate, and Transportation Economics - - Real Estate Markets, Spatial Production Analysis, and Firm Location - - - Other Spatial Production and Pricing Analysis

    Statistics

    Access and download statistics

    Corrections

    All material on this site has been provided by the respective publishers and authors. You can help correct errors and omissions. When requesting a correction, please mention this item's handle: RePEc:eee:energy:v:112:y:2016:i:c:p:179-187. See general information about how to correct material in RePEc.

    If you have authored this item and are not yet registered with RePEc, we encourage you to do it here. This allows to link your profile to this item. It also allows you to accept potential citations to this item that we are uncertain about.

    If CitEc recognized a bibliographic reference but did not link an item in RePEc to it, you can help with this form .

    If you know of missing items citing this one, you can help us creating those links by adding the relevant references in the same way as above, for each refering item. If you are a registered author of this item, you may also want to check the "citations" tab in your RePEc Author Service profile, as there may be some citations waiting for confirmation.

    For technical questions regarding this item, or to correct its authors, title, abstract, bibliographic or download information, contact: Catherine Liu (email available below). General contact details of provider: http://www.journals.elsevier.com/energy .

    Please note that corrections may take a couple of weeks to filter through the various RePEc services.

    IDEAS is a RePEc service. RePEc uses bibliographic data supplied by the respective publishers.