IDEAS home Printed from https://ideas.repec.org/a/spr/ijsaem/v8y2017i2d10.1007_s13198-017-0679-4.html
   My bibliography  Save this article

Predictive model approach based direct power control for power quality conditioning

Author

Listed:
  • Houssam Eddine Medouce

    (Mentouri Brothers University)

  • Hocine Benalla

    (Mentouri Brothers University)

Abstract

This paper has presented improved control structure based direct power control (DPC) applied for shunt active power filtering. Basically, DPC control strategy employs instantaneous active and reactive power terms as controlled variables. This work introduces an integration concept of predictive control algorithm for shunt active power filter system application. Process of this latter adopts discrete model of PWM converter in the aim to predict future behaviour of the system. Switching vector selection principles for predictive control is very different compared to conventional method. For conventional DPC the selection is performed via heuristic switching table while predictive DPC algorithm takes on an optimized way based on cost function minimization depending to power errors, this latter evaluate the effects of each active voltage vector and the one reducing the cost function is chosen to be applied in the next sampling period. The application of optimal switching state leads to regulate the input active and reactive power which resulted in the cancellation of harmonic power component contained in the network. Simulation results are presented to verify the validity and effectiveness of the proposed predictive DPC in terms of dynamic and steady state performance for shunt active power filtering application.

Suggested Citation

  • Houssam Eddine Medouce & Hocine Benalla, 2017. "Predictive model approach based direct power control for power quality conditioning," International Journal of System Assurance Engineering and Management, Springer;The Society for Reliability, Engineering Quality and Operations Management (SREQOM),India, and Division of Operation and Maintenance, Lulea University of Technology, Sweden, vol. 8(2), pages 1832-1848, November.
  • Handle: RePEc:spr:ijsaem:v:8:y:2017:i:2:d:10.1007_s13198-017-0679-4
    DOI: 10.1007/s13198-017-0679-4
    as

    Download full text from publisher

    File URL: http://link.springer.com/10.1007/s13198-017-0679-4
    File Function: Abstract
    Download Restriction: Access to the full text of the articles in this series is restricted.

    File URL: https://libkey.io/10.1007/s13198-017-0679-4?utm_source=ideas
    LibKey link: if access is restricted and if your library uses this service, LibKey will redirect you to where you can use your library subscription to access this item
    ---><---

    As the access to this document is restricted, you may want to search for a different version of it.

    References listed on IDEAS

    as
    1. Kamel Djazia & Fateh Krim & Abdelmadjid Chaoui & Mustapha Sarra, 2015. "Active Power Filtering Using the ZDPC Method under Unbalanced and Distorted Grid Voltage Conditions," Energies, MDPI, vol. 8(3), pages 1-22, February.
    Full references (including those not matched with items on IDEAS)

    Citations

    Citations are extracted by the CitEc Project, subscribe to its RSS feed for this item.
    as


    Cited by:

    1. Garima Goswami & Pankaj Kumar Goswami, 2021. "A design analysis and implementation of PI, PID and fuzzy supervised shunt APF at nonlinear load application to improve power quality and system reliability," International Journal of System Assurance Engineering and Management, Springer;The Society for Reliability, Engineering Quality and Operations Management (SREQOM),India, and Division of Operation and Maintenance, Lulea University of Technology, Sweden, vol. 12(6), pages 1247-1261, December.

    Most related items

    These are the items that most often cite the same works as this one and are cited by the same works as this one.
    1. Nor Farahaida Abdul Rahman & Mohd Amran Mohd Radzi & Azura Che Soh & Norman Mariun & Nasrudin Abd Rahim, 2016. "Adaptive Hybrid Fuzzy-Proportional Plus Crisp-Integral Current Control Algorithm for Shunt Active Power Filter Operation," Energies, MDPI, vol. 9(9), pages 1-18, September.
    2. Yap Hoon & Mohd Amran Mohd Radzi & Mohd Khair Hassan & Nashiren Farzilah Mailah, 2017. "Control Algorithms of Shunt Active Power Filter for Harmonics Mitigation: A Review," Energies, MDPI, vol. 10(12), pages 1-29, December.
    3. Amirreza Naderipour & Zulkurnain Abdul-Malek & Mohammad Reza Miveh & Mohammad Jafar Hadidian Moghaddam & Akhtar Kalam & Foad. H. Gandoman, 2018. "A Harmonic Compensation Strategy in a Grid-Connected Photovoltaic System Using Zero-Sequence Control," Energies, MDPI, vol. 11(10), pages 1-18, October.
    4. Tanzim Meraj, Sheikh & Zaihar Yahaya, Nor & Hasan, Kamrul & Hossain Lipu, M.S. & Madurai Elavarasan, Rajvikram & Hussain, Aini & Hannan, M.A. & Muttaqi, Kashem M., 2022. "A filter less improved control scheme for active/reactive energy management in fuel cell integrated grid system with harmonic reduction ability," Applied Energy, Elsevier, vol. 312(C).
    5. Yap Hoon & Mohd Amran Mohd Radzi & Mohd Khair Hassan & Nashiren Farzilah Mailah, 2017. "A Self-Tuning Filter-Based Adaptive Linear Neuron Approach for Operation of Three-Level Inverter-Based Shunt Active Power Filters under Non-Ideal Source Voltage Conditions," Energies, MDPI, vol. 10(5), pages 1-28, May.
    6. Yap Hoon & Mohd Amran Mohd Radzi, 2018. "PLL-Less Three-Phase Four-Wire SAPF with STF- dq 0 Technique for Harmonics Mitigation under Distorted Supply Voltage and Unbalanced Load Conditions," Energies, MDPI, vol. 11(8), pages 1-27, August.
    7. Yap Hoon & Mohd Amran Mohd Radzi & Mohd Khair Hassan & Nashiren Farzilah Mailah, 2016. "DC-Link Capacitor Voltage Regulation for Three-Phase Three-Level Inverter-Based Shunt Active Power Filter with Inverted Error Deviation Control," Energies, MDPI, vol. 9(7), pages 1-25, July.
    8. Yap Hoon & Mohd Amran Mohd Radzi & Mohd Khair Hassan & Nashiren Farzilah Mailah, 2017. "A Refined Self-Tuning Filter-Based Instantaneous Power Theory Algorithm for Indirect Current Controlled Three-Level Inverter-Based Shunt Active Power Filters under Non-sinusoidal Source Voltage Condit," Energies, MDPI, vol. 10(3), pages 1-21, February.

    Corrections

    All material on this site has been provided by the respective publishers and authors. You can help correct errors and omissions. When requesting a correction, please mention this item's handle: RePEc:spr:ijsaem:v:8:y:2017:i:2:d:10.1007_s13198-017-0679-4. See general information about how to correct material in RePEc.

    If you have authored this item and are not yet registered with RePEc, we encourage you to do it here. This allows to link your profile to this item. It also allows you to accept potential citations to this item that we are uncertain about.

    If CitEc recognized a bibliographic reference but did not link an item in RePEc to it, you can help with this form .

    If you know of missing items citing this one, you can help us creating those links by adding the relevant references in the same way as above, for each refering item. If you are a registered author of this item, you may also want to check the "citations" tab in your RePEc Author Service profile, as there may be some citations waiting for confirmation.

    For technical questions regarding this item, or to correct its authors, title, abstract, bibliographic or download information, contact: Sonal Shukla or Springer Nature Abstracting and Indexing (email available below). General contact details of provider: http://www.springer.com .

    Please note that corrections may take a couple of weeks to filter through the various RePEc services.

    IDEAS is a RePEc service. RePEc uses bibliographic data supplied by the respective publishers.