Energy Performance Analysis and Study of an Office Building in an Extremely Hot and Cold Region

Author

Listed:
  • Yunbo Liu

    (College of Architectural and Civil Engineering, Xinjiang University, Urumqi 830017, China)

  • Wanjiang Wang

    (College of Architectural and Civil Engineering, Xinjiang University, Urumqi 830017, China)

  • Yumeng Huang

    (College of Architectural and Civil Engineering, Xinjiang University, Urumqi 830017, China)

  • Junkang Song

    (College of Architectural and Environment, Sichuan University, Chengdu 610000, China)

  • Zhenan Zhou

    (School of Control and Computer Engineering, North China Electric Power University, Baoding 071000, China)

Abstract

China is committed to reaching peak carbon by 2030 and carbon neutrality by 2060. The goals of reducing energy consumption and building a “beautiful China” are being urgently pursued in China. The building studied in this paper is located in the city of Turpan, where the problem of excessive energy use among buildings is significant due to the region’s hot summers and cold winters. Additionally, the fact that the office building studied in this paper has an east–west orientation is significant: the building’s main façade is oriented to the west, comprising a large area of single-layer glass curtain wall. Based on this, this paper proposes optimization strategies from two perspectives of renovation and new construction. Four design options are proposed at the retrofit level: glazed circular curtain wall; glazed enclosed curtain wall; west-facing double-glazed curtain wall circulation combined with south-facing light from the east; recycling of windows on the inside of the exterior glass curtain wall. These suggestions focus on retrofitting the glass curtain wall on the west elevation of the building. Two design options are proposed at the new-build level: west-facing south-oriented light and west-facing north-oriented light. These suggestions were primarily built around the idea of changing the orientation of the windows on the west elevation. The results show that the optimal solution is to implement the west-facing double-glazed curtain wall circulation combined with south-facing light from the east. This program shows a 64.14% reduction in heating energy consumption, a 77.12% reduction in cooling energy consumption, and a 69.67% reduction in total energy consumption. The above research has improved the deficiencies in the performance-based energy efficiency retrofit of office buildings in the region and provided new ideas and suggestions for policymakers and designers to build energy-efficiency retrofits in the early stages.

Suggested Citation

  • Yunbo Liu & Wanjiang Wang & Yumeng Huang & Junkang Song & Zhenan Zhou, 2024. "Energy Performance Analysis and Study of an Office Building in an Extremely Hot and Cold Region," Sustainability, MDPI, vol. 16(2), pages 1-29, January.
  • Handle: RePEc:gam:jsusta:v:16:y:2024:i:2:p:572-:d:1315816
    as

    Download full text from publisher

    File URL: https://www.mdpi.com/2071-1050/16/2/572/pdf
    Download Restriction: no

    File URL: https://www.mdpi.com/2071-1050/16/2/572/
    Download Restriction: no
    ---><---

    References listed on IDEAS

    as
    1. Xiaodong Yuan & Weiling Song, 2022. "Evaluating technology innovation capabilities of companies based on entropy- TOPSIS: the case of solar cell companies," Information Technology and Management, Springer, vol. 23(2), pages 65-76, June.
    2. Palmero-Marrero, Ana I. & Oliveira, Armando C., 2010. "Effect of louver shading devices on building energy requirements," Applied Energy, Elsevier, vol. 87(6), pages 2040-2049, June.
    3. Singh, Ramkishore & Lazarus, I.J. & Kishore, V.V.N., 2016. "Uncertainty and sensitivity analyses of energy and visual performances of office building with external venetian blind shading in hot-dry climate," Applied Energy, Elsevier, vol. 184(C), pages 155-170.
    Full references (including those not matched with items on IDEAS)

    Most related items

    These are the items that most often cite the same works as this one and are cited by the same works as this one.
    1. Wu, Yujie & Kämpf, Jérôme H. & Scartezzini, Jean-Louis, 2019. "Automated ‘Eye-sight’ Venetian blinds based on an embedded photometric device with real-time daylighting computing," Applied Energy, Elsevier, vol. 252(C), pages 1-1.
    2. Souayfane, Farah & Biwole, Pascal Henry & Fardoun, Farouk, 2018. "Thermal behavior of a translucent superinsulated latent heat energy storage wall in summertime," Applied Energy, Elsevier, vol. 217(C), pages 390-408.
    3. Dong Eun Jung & Chanuk Lee & Kwang Ho Lee & Minjae Shin & Sung Lok Do, 2021. "Evaluation of Building Energy Performance with Optimal Control of Movable Shading Device Integrated with PV System," Energies, MDPI, vol. 14(7), pages 1-21, March.
    4. Małgorzata Fedorczak-Cisak & Katarzyna Nowak & Marcin Furtak, 2019. "Analysis of the Effect of Using External Venetian Blinds on the Thermal Comfort of Users of Highly Glazed Office Rooms in a Transition Season of Temperate Climate—Case Study," Energies, MDPI, vol. 13(1), pages 1-18, December.
    5. Sara Brito-Coimbra & Daniel Aelenei & Maria Gloria Gomes & Antonio Moret Rodrigues, 2021. "Building Façade Retrofit with Solar Passive Technologies: A Literature Review," Energies, MDPI, vol. 14(6), pages 1-18, March.
    6. Kirimtat, Ayca & Koyunbaba, Basak Kundakci & Chatzikonstantinou, Ioannis & Sariyildiz, Sevil, 2016. "Review of simulation modeling for shading devices in buildings," Renewable and Sustainable Energy Reviews, Elsevier, vol. 53(C), pages 23-49.
    7. Taveres-Cachat, Ellika & Lobaccaro, Gabriele & Goia, Francesco & Chaudhary, Gaurav, 2019. "A methodology to improve the performance of PV integrated shading devices using multi-objective optimization," Applied Energy, Elsevier, vol. 247(C), pages 731-744.
    8. Sun, Yanyi & Liang, Runqi & Wu, Yupeng & Wilson, Robin & Rutherford, Peter, 2017. "Development of a comprehensive method to analyse glazing systems with Parallel Slat Transparent Insulation material (PS-TIM)," Applied Energy, Elsevier, vol. 205(C), pages 951-963.
    9. Liu, Mingzhe & Wittchen, Kim Bjarne & Heiselberg, Per Kvols, 2015. "Control strategies for intelligent glazed façade and their influence on energy and comfort performance of office buildings in Denmark," Applied Energy, Elsevier, vol. 145(C), pages 43-51.
    10. Liu, Zhongbing & Zhang, Yelin & Zhang, Ling & Luo, Yongqiang & Wu, Zhenghong & Wu, Jing & Yin, Yingde & Hou, Guoqing, 2018. "Modeling and simulation of a photovoltaic thermal-compound thermoelectric ventilator system," Applied Energy, Elsevier, vol. 228(C), pages 1887-1900.
    11. Abdo Abdullah Ahmed Gassar & Choongwan Koo & Tae Wan Kim & Seung Hyun Cha, 2021. "Performance Optimization Studies on Heating, Cooling and Lighting Energy Systems of Buildings during the Design Stage: A Review," Sustainability, MDPI, vol. 13(17), pages 1-47, September.
    12. Ángel Gómez-Moreno & Pedro José Casanova-Peláez & José Manuel Palomar-Carnicero & Fernando Cruz-Peragón, 2016. "Modeling and Experimental Validation of a Low-Cost Radiation Sensor Based on the Photovoltaic Effect for Building Applications," Energies, MDPI, vol. 9(11), pages 1-16, November.
    13. Wang, Ran & Lu, Shilei & Feng, Wei, 2020. "Impact of adjustment strategies on building design process in different climates oriented by multiple performance," Applied Energy, Elsevier, vol. 266(C).
    14. Byungyun Lee, 2019. "Heating, Cooling, and Lighting Energy Demand Simulation Analysis of Kinetic Shading Devices with Automatic Dimming Control for Asian Countries," Sustainability, MDPI, vol. 11(5), pages 1-20, February.
    15. Hu, Zhongting & He, Wei & Hu, Dengyun & Lv, Song & Wang, Liping & Ji, Jie & Chen, Hongbing & Ma, Jinwei, 2017. "Design, construction and performance testing of a PV blind-integrated Trombe wall module," Applied Energy, Elsevier, vol. 203(C), pages 643-656.
    16. Stevanović, Sanja, 2013. "Optimization of passive solar design strategies: A review," Renewable and Sustainable Energy Reviews, Elsevier, vol. 25(C), pages 177-196.
    17. Tian, Wei & Heo, Yeonsook & de Wilde, Pieter & Li, Zhanyong & Yan, Da & Park, Cheol Soo & Feng, Xiaohang & Augenbroe, Godfried, 2018. "A review of uncertainty analysis in building energy assessment," Renewable and Sustainable Energy Reviews, Elsevier, vol. 93(C), pages 285-301.
    18. Aiman Mohammed & Muhammad Atiq Ur Rehman Tariq & Anne Wai Man Ng & Zeeshan Zaheer & Safwan Sadeq & Mahmood Mohammed & Hooman Mehdizadeh-Rad, 2022. "Reducing the Cooling Loads of Buildings Using Shading Devices: A Case Study in Darwin," Sustainability, MDPI, vol. 14(7), pages 1-20, March.
    19. Gago, E.J. & Muneer, T. & Knez, M. & Köster, H., 2015. "Natural light controls and guides in buildings. Energy saving for electrical lighting, reduction of cooling load," Renewable and Sustainable Energy Reviews, Elsevier, vol. 41(C), pages 1-13.
    20. Ramkishore Singh & Dharam Buddhi & Samar Thapa & Chander Prakash & Rajesh Singh & Atul Sharma & Shane Sheoran & Kuldeep Kumar Saxena, 2022. "Sensitivity Analysis for Decisive Design Parameters for Energy and Indoor Visual Performances of a Glazed Façade Office Building," Sustainability, MDPI, vol. 14(21), pages 1-27, October.

    Corrections

    All material on this site has been provided by the respective publishers and authors. You can help correct errors and omissions. When requesting a correction, please mention this item's handle: RePEc:gam:jsusta:v:16:y:2024:i:2:p:572-:d:1315816. See general information about how to correct material in RePEc.

    If you have authored this item and are not yet registered with RePEc, we encourage you to do it here. This allows to link your profile to this item. It also allows you to accept potential citations to this item that we are uncertain about.

    If CitEc recognized a bibliographic reference but did not link an item in RePEc to it, you can help with this form .

    If you know of missing items citing this one, you can help us creating those links by adding the relevant references in the same way as above, for each refering item. If you are a registered author of this item, you may also want to check the "citations" tab in your RePEc Author Service profile, as there may be some citations waiting for confirmation.

    For technical questions regarding this item, or to correct its authors, title, abstract, bibliographic or download information, contact: MDPI Indexing Manager (email available below). General contact details of provider: https://www.mdpi.com .

    Please note that corrections may take a couple of weeks to filter through the various RePEc services.

    IDEAS is a RePEc service. RePEc uses bibliographic data supplied by the respective publishers.