IDEAS home Printed from https://ideas.repec.org/a/gam/jsusta/v14y2022i17p11095-d907256.html
   My bibliography  Save this article

Temporal Segmentation for the Estimation and Benchmarking of Heating and Cooling Energy in Commercial Buildings in Seoul, South Korea

Author

Listed:
  • Ki Uhn Ahn

    (Department of Building Research, Korea Institute of Civil Engineering and Building Technology, Goyang-si 10223, Korea)

  • Deuk-Woo Kim

    (Department of Building Energy Research, Korea Institute of Civil Engineering and Building Technology, Goyang-si 10223, Korea)

  • Seung-Eon Lee

    (Department of Building Energy Research, Korea Institute of Civil Engineering and Building Technology, Goyang-si 10223, Korea)

  • Chang-U Chae

    (Research Strategic Planning Department, Korea Institute of Civil Engineering and Building Technology, Goyang-si 10223, Korea)

  • Hyun Mi Cho

    (Department of Building Research, Korea Institute of Civil Engineering and Building Technology, Goyang-si 10223, Korea)

Abstract

The building sector is responsible for more than one-third of total global energy consumption; hence, increasingly efficient energy use in this sector will contribute to achieving carbon neutrality. Most existing building-energy-benchmarking methods evaluate building energy performance based on total energy use intensity; however, energy usage in buildings varies with the seasons, and as such, this approach renders the evaluation of cooling and heating energy difficult. In this study, an information gain-based temporal segmentation (IGTS) method was used to identify the seasonal transition times based on patterns of hourly weather and corresponding building energy use. Twelve commercial buildings were considered for the study and four seasons were identified using IGTS; base-load, cooling energy, and heating energy data were gathered. For the 12 buildings, the estimated and measured heating and cooling energy during the summer and winter periods showed a linear relationship (R 2 = 0.976), and the average of those differences was 9.07 kWh/m 2 . In addition, differences in the benchmarking results based on these energies were marginal. The results indicated that the IGTS approach can be effectively used for determining the actual heating and cooling energy consumption in buildings, as well as for energy benchmarking. This can, in turn, improve building energy use, with positive implications for achieving carbon neutrality.

Suggested Citation

  • Ki Uhn Ahn & Deuk-Woo Kim & Seung-Eon Lee & Chang-U Chae & Hyun Mi Cho, 2022. "Temporal Segmentation for the Estimation and Benchmarking of Heating and Cooling Energy in Commercial Buildings in Seoul, South Korea," Sustainability, MDPI, vol. 14(17), pages 1-14, September.
  • Handle: RePEc:gam:jsusta:v:14:y:2022:i:17:p:11095-:d:907256
    as

    Download full text from publisher

    File URL: https://www.mdpi.com/2071-1050/14/17/11095/pdf
    Download Restriction: no

    File URL: https://www.mdpi.com/2071-1050/14/17/11095/
    Download Restriction: no
    ---><---

    References listed on IDEAS

    as
    1. Chung, William, 2011. "Review of building energy-use performance benchmarking methodologies," Applied Energy, Elsevier, vol. 88(5), pages 1470-1479, May.
    2. Reifschneider, David & Stevenson, Rodney, 1991. "Systematic Departures from the Frontier: A Framework for the Analysis of Firm Inefficiency," International Economic Review, Department of Economics, University of Pennsylvania and Osaka University Institute of Social and Economic Research Association, vol. 32(3), pages 715-723, August.
    3. Seong-Hwan Yoon & Cheol-Soo Park, 2017. "Objective Building Energy Performance Benchmarking Using Data Envelopment Analysis and Monte Carlo Sampling," Sustainability, MDPI, vol. 9(5), pages 1-12, May.
    4. Chung, William & Hui, Y.V. & Lam, Y. Miu, 2006. "Benchmarking the energy efficiency of commercial buildings," Applied Energy, Elsevier, vol. 83(1), pages 1-14, January.
    5. Aigner, Dennis & Lovell, C. A. Knox & Schmidt, Peter, 1977. "Formulation and estimation of stochastic frontier production function models," Journal of Econometrics, Elsevier, vol. 6(1), pages 21-37, July.
    Full references (including those not matched with items on IDEAS)

    Most related items

    These are the items that most often cite the same works as this one and are cited by the same works as this one.
    1. Chung, William, 2011. "Review of building energy-use performance benchmarking methodologies," Applied Energy, Elsevier, vol. 88(5), pages 1470-1479, May.
    2. Chung, William & Yeung, Iris M.H., 2017. "Benchmarking by convex non-parametric least squares with application on the energy performance of office buildings," Applied Energy, Elsevier, vol. 203(C), pages 454-462.
    3. Noel Uri, 2003. "The Effect of Incentive Regulation in Telecommunications in the United States," Quality & Quantity: International Journal of Methodology, Springer, vol. 37(2), pages 169-191, May.
    4. Roy, Manish & Mazumder, Ritwik, 2016. "Technical Efficiency of Fish Catch in Traditional Fishing: A Study in Southern Assam," Journal of Regional Development and Planning, Rajarshi Majumder, vol. 5(1), pages 55-68.
    5. Simar, Leopold & Wilson, Paul W., 2007. "Estimation and inference in two-stage, semi-parametric models of production processes," Journal of Econometrics, Elsevier, vol. 136(1), pages 31-64, January.
    6. Edward Ebo ONUMAH & Bernhard BRÜMMER & Gabriele HÖRSTGEN-SCHWARK, 2010. "Productivity of the hired and family labour and determinants of technical inefficiency in Ghana's fish farms," Agricultural Economics, Czech Academy of Agricultural Sciences, vol. 56(2), pages 79-88.
    7. Muktar Geleto & Mohammed Essa, 2022. "Analysis of Red Pepper Production Risk Adjusted Technical Efficiency: The Case Of Lanfuro District In Siltie Zone, Southern Ethiopia," International Journal of Business and Management, International Institute of Social and Economic Sciences, vol. 10(1), pages 30-58, May.
    8. Coelli, Tim J. & Battese, George E., 1996. "Identification Of Factors Which Influence The Technical Inefficiency Of Indian Farmers," Australian Journal of Agricultural Economics, Australian Agricultural and Resource Economics Society, vol. 40(2), pages 1-26, August.
    9. Bottasso, Anna & Conti, Maurizio, 2003. "Cost Inefficiency in the English and Welsh Water Industry: An Heteroskedastic Stochastic Cost Frontier Approach," Economics Discussion Papers 8872, University of Essex, Department of Economics.
    10. Roberto Furesi & Fabio Madau & Pietro Pulina, 2013. "Technical efficiency in the sheep dairy industry: an application on the Sardinian (Italy) sector," Agricultural and Food Economics, Springer;Italian Society of Agricultural Economics (SIDEA), vol. 1(1), pages 1-11, December.
    11. Christopher F. Parmeter & Hung-Jen Wang & Subal C. Kumbhakar, 2017. "Nonparametric estimation of the determinants of inefficiency," Journal of Productivity Analysis, Springer, vol. 47(3), pages 205-221, June.
    12. Helvoigt, Ted L. & Adams, Darius M., 2009. "A stochastic frontier analysis of technical progress, efficiency change and productivity growth in the Pacific Northwest sawmill industry," Forest Policy and Economics, Elsevier, vol. 11(4), pages 280-287, July.
    13. Henderson, Benjamin B. & Kingwell, Ross S., 2001. "An Investigation of the Technical and Allocative Efficiency of Broadacre Farmers," 2002 Conference (46th), February 13-15, 2002, Canberra, Australia 125109, Australian Agricultural and Resource Economics Society.
    14. Federica VIGANO & Andrea SALUSTRI, 2015. "Matching profit and Non-profit Needs: How NPOs and Cooperative Contribute to Growth in Time of Crisis. A Quantitative Approach," Annals of Public and Cooperative Economics, Wiley Blackwell, vol. 86(1), pages 157-178, March.
    15. Amsler, Christine & Prokhorov, Artem & Schmidt, Peter, 2017. "Endogenous environmental variables in stochastic frontier models," Journal of Econometrics, Elsevier, vol. 199(2), pages 131-140.
    16. Zhou, Yuren & Lork, Clement & Li, Wen-Tai & Yuen, Chau & Keow, Yeong Ming, 2019. "Benchmarking air-conditioning energy performance of residential rooms based on regression and clustering techniques," Applied Energy, Elsevier, vol. 253(C), pages 1-1.
    17. Rita, Rui & Marques, Vitor & Bárbara, Diogo & Chaves, Inês & Macedo, Pedro & Moutinho, Victor & Pereira, Mariana, 2023. "Crossing non-parametric and parametric techniques for measuring the efficiency: Evidence from 65 European electricity Distribution System Operators," Energy, Elsevier, vol. 283(C).
    18. Deng, Yaguo, 2024. "A Bayesian semi-parametric approach to stochastic frontier models with inefficiency heterogeneity," DES - Working Papers. Statistics and Econometrics. WS 43837, Universidad Carlos III de Madrid. Departamento de Estadística.
    19. Tzouvelekas, Vangelis & Pantzios, Christos J. & Fotopoulos, Christos, 2001. "Technical efficiency of alternative farming systems: the case of Greek organic and conventional olive-growing farms," Food Policy, Elsevier, vol. 26(6), pages 549-569, December.
    20. Masood, Tariq & Ahmad, Mohd. Izhar, 2010. "Technical Efficiency of Microfinance Institutions in India- A Stochastic Frontier Approach," MPRA Paper 25454, University Library of Munich, Germany.

    Corrections

    All material on this site has been provided by the respective publishers and authors. You can help correct errors and omissions. When requesting a correction, please mention this item's handle: RePEc:gam:jsusta:v:14:y:2022:i:17:p:11095-:d:907256. See general information about how to correct material in RePEc.

    If you have authored this item and are not yet registered with RePEc, we encourage you to do it here. This allows to link your profile to this item. It also allows you to accept potential citations to this item that we are uncertain about.

    If CitEc recognized a bibliographic reference but did not link an item in RePEc to it, you can help with this form .

    If you know of missing items citing this one, you can help us creating those links by adding the relevant references in the same way as above, for each refering item. If you are a registered author of this item, you may also want to check the "citations" tab in your RePEc Author Service profile, as there may be some citations waiting for confirmation.

    For technical questions regarding this item, or to correct its authors, title, abstract, bibliographic or download information, contact: MDPI Indexing Manager (email available below). General contact details of provider: https://www.mdpi.com .

    Please note that corrections may take a couple of weeks to filter through the various RePEc services.

    IDEAS is a RePEc service. RePEc uses bibliographic data supplied by the respective publishers.