Experimental and Numerical Study on Air Cooling System Dedicated to Photovoltaic Panels

Author

Listed:
  • Maksymilian Homa

    (Department of Sustainable Energy Development, Faculty of Energy and Fuels, AGH University of Krakow, Mickiewicza Av. 30, 30-059 Krakow, Poland)

  • Krzysztof Sornek

    (Department of Sustainable Energy Development, Faculty of Energy and Fuels, AGH University of Krakow, Mickiewicza Av. 30, 30-059 Krakow, Poland)

  • Wojciech Goryl

    (Department of Sustainable Energy Development, Faculty of Energy and Fuels, AGH University of Krakow, Mickiewicza Av. 30, 30-059 Krakow, Poland)

Abstract

The efficiency of solar systems, in particular photovoltaic panels, is typically low. Various environmental parameters affect solar panels, including sunlight, the ambient and module surface temperatures, the wind speed, humidity, shading, dust, the installation height, etc. Among others, the key players are indeed solar irradiance and temperature. The higher the temperature is, the higher the short-circuit current is, and the lower the open-circuit voltage is. The negative effect of lowering the open-circuit voltage is dominant, consequently lowering the power of the photovoltaic panels. Passive or active cooling systems can be provided to avoid the negative effect of temperature. This paper presents a prototype of an active cooling system dedicated to photovoltaics. The prototype of such a system was developed at the AGH University of Kraków and tested under laboratory conditions. The proposed system is equipped with air fans mounted on a plate connected to the rear part of a 70 Wp photovoltaic panel. Different configurations of the system were tested, including different numbers of fans and different locations of the fans. The artificial light source generated a irradiation value of 770 W/m 2 . This value was present for every variant tested in the experiment. As observed, the maximum power generated in the photovoltaic panel under laboratory conditions was approx. 47.31 W. Due to the temperature increase, this power was reduced to 40.09 W (when the temperature of the uncooled panel surface reached 60 °C). On the other hand, the power generated in the photovoltaic panel equipped with the developed cooling system was approx. 44.37 W in the same conditions (i.e., it was higher by 10.7% compared to that of the uncooled one). A mathematical model was developed based on the results obtained, and simulations were carried out using the ANSYS Workbench software. After the validation procedure, several configurations of the air cooling system were developed and analyzed. The most prominent case was chosen for additional parametrical analysis. The optimum fan orientation was recognized: a vertical tilt of 7° and a horizontal tilt of 10°. For the tested module, this modification resulted in a cost-effective system (a net power increase of ~3.1%).

Suggested Citation

  • Maksymilian Homa & Krzysztof Sornek & Wojciech Goryl, 2024. "Experimental and Numerical Study on Air Cooling System Dedicated to Photovoltaic Panels," Energies, MDPI, vol. 17(16), pages 1-21, August.
  • Handle: RePEc:gam:jeners:v:17:y:2024:i:16:p:3949-:d:1453099
    as

    Download full text from publisher

    File URL: https://www.mdpi.com/1996-1073/17/16/3949/pdf
    Download Restriction: no

    File URL: https://www.mdpi.com/1996-1073/17/16/3949/
    Download Restriction: no
    ---><---

    References listed on IDEAS

    as
    1. Al-Amri, Fahad & Saeed, Farooq & Mujeebu, Muhammad Abdul, 2022. "Novel dual-function racking structure for passive cooling of solar PV panels –thermal performance analysis," Renewable Energy, Elsevier, vol. 198(C), pages 100-113.
    2. Duan, Juan, 2021. "The PCM-porous system used to cool the inclined PV panel," Renewable Energy, Elsevier, vol. 180(C), pages 1315-1332.
    Full references (including those not matched with items on IDEAS)

    Most related items

    These are the items that most often cite the same works as this one and are cited by the same works as this one.
    1. Sohani, Ali & Cornaro, Cristina & Shahverdian, Mohammad Hassan & Hoseinzadeh, Siamak & Moser, David & Nastasi, Benedetto & Sayyaadi, Hoseyn & Astiaso Garcia, Davide, 2023. "Thermography and machine learning combination for comprehensive analysis of transient response of a photovoltaic module to water cooling," Renewable Energy, Elsevier, vol. 210(C), pages 451-461.
    2. Kong, Xiangfei & Zhang, Lanlan & Li, Han & Wang, Yongzhen & Fan, Man, 2022. "Effect of solar energy concentrating and phase change cooling on energy and exergy performance improvement of photovoltaic/thermal systems," Renewable Energy, Elsevier, vol. 197(C), pages 1251-1263.
    3. Tarek Ibrahim & Mohamad Abou Akrouch & Farouk Hachem & Mohamad Ramadan & Haitham S. Ramadan & Mahmoud Khaled, 2024. "Cooling Techniques for Enhanced Efficiency of Photovoltaic Panels—Comparative Analysis with Environmental and Economic Insights," Energies, MDPI, vol. 17(3), pages 1-32, February.
    4. Gad, Ramadan & Mahmoud, Hatem & Hassan, Hamdy, 2023. "Performance evaluation of direct and indirect thermal regulation of low concentrated (via compound parabolic collector) solar panel using phase change material-flat heat pipe cooling system," Energy, Elsevier, vol. 274(C).
    5. Yildirim, Mehmet Ali & Cebula, Artur & Sułowicz, Maciej, 2022. "A cooling design for photovoltaic panels – Water-based PV/T system," Energy, Elsevier, vol. 256(C).
    6. Ke, Wei & Ji, Jie & Zhang, Chengyan & Song, Zhiying & Wang, Chuyao & Xie, Hao & Tian, Xinyi, 2024. "Performance analysis of a novel hybrid CdTe-PCM multi-layer ventilated window system for building application: An experimental and numerical study," Energy, Elsevier, vol. 293(C).
    7. Altegoer, D. & Hussong, J. & Lindken, R., 2022. "Efficiency increase of photovoltaic systems by means of evaporative cooling in a back-mounted chimney-like channel," Renewable Energy, Elsevier, vol. 191(C), pages 557-570.

    Corrections

    All material on this site has been provided by the respective publishers and authors. You can help correct errors and omissions. When requesting a correction, please mention this item's handle: RePEc:gam:jeners:v:17:y:2024:i:16:p:3949-:d:1453099. See general information about how to correct material in RePEc.

    If you have authored this item and are not yet registered with RePEc, we encourage you to do it here. This allows to link your profile to this item. It also allows you to accept potential citations to this item that we are uncertain about.

    If CitEc recognized a bibliographic reference but did not link an item in RePEc to it, you can help with this form .

    If you know of missing items citing this one, you can help us creating those links by adding the relevant references in the same way as above, for each refering item. If you are a registered author of this item, you may also want to check the "citations" tab in your RePEc Author Service profile, as there may be some citations waiting for confirmation.

    For technical questions regarding this item, or to correct its authors, title, abstract, bibliographic or download information, contact: MDPI Indexing Manager (email available below). General contact details of provider: https://www.mdpi.com .

    Please note that corrections may take a couple of weeks to filter through the various RePEc services.

    IDEAS is a RePEc service. RePEc uses bibliographic data supplied by the respective publishers.