IDEAS home Printed from https://ideas.repec.org/a/gam/jeners/v16y2023i12p4826-d1175296.html
   My bibliography  Save this article

Anti-Condensation Temperature Control Strategy of the Concrete Radiant Roof

Author

Listed:
  • Bobo Zhang

    (Guangzhou Institute of Energy Conversion, Chinese Academy of Sciences, Guangzhou 510640, China
    CAS Key Laboratory of Renewable Energy, Guangzhou 510640, China
    Guangdong Provincial Key Laboratory of New and Renewable Energy Research and Development, Guangzhou 510640, China)

  • Qin Sun

    (Guangzhou Institute of Energy Conversion, Chinese Academy of Sciences, Guangzhou 510640, China
    CAS Key Laboratory of Renewable Energy, Guangzhou 510640, China
    Guangdong Provincial Key Laboratory of New and Renewable Energy Research and Development, Guangzhou 510640, China)

  • Lin Su

    (Guangzhou Institute of Energy Conversion, Chinese Academy of Sciences, Guangzhou 510640, China
    CAS Key Laboratory of Renewable Energy, Guangzhou 510640, China
    Guangdong Provincial Key Laboratory of New and Renewable Energy Research and Development, Guangzhou 510640, China)

  • Kaijun Dong

    (Guangzhou Institute of Energy Conversion, Chinese Academy of Sciences, Guangzhou 510640, China
    CAS Key Laboratory of Renewable Energy, Guangzhou 510640, China
    Guangdong Provincial Key Laboratory of New and Renewable Energy Research and Development, Guangzhou 510640, China)

  • Weimin Luo

    (Guangzhou Institute of Energy Conversion, Chinese Academy of Sciences, Guangzhou 510640, China
    CAS Key Laboratory of Renewable Energy, Guangzhou 510640, China
    Guangdong Provincial Key Laboratory of New and Renewable Energy Research and Development, Guangzhou 510640, China)

  • Haifeng Guan

    (Guangzhou Institute of Energy Conversion, Chinese Academy of Sciences, Guangzhou 510640, China
    CAS Key Laboratory of Renewable Energy, Guangzhou 510640, China
    Guangdong Provincial Key Laboratory of New and Renewable Energy Research and Development, Guangzhou 510640, China)

  • Zhenhua Shao

    (Guangzhou Institute of Energy Conversion, Chinese Academy of Sciences, Guangzhou 510640, China
    CAS Key Laboratory of Renewable Energy, Guangzhou 510640, China
    Guangdong Provincial Key Laboratory of New and Renewable Energy Research and Development, Guangzhou 510640, China)

  • Wei Wu

    (School of Energy and Environment, City University of Hong Kong, Hong Kong, China)

Abstract

Radiation cooling, as a new terminal mode that has been gradually emerging in recent years, has attracted more and more attention. However, the problem of condensation has become a vital bottleneck restricting the broad application of radiation-cooling technology. This paper used the numerical simulation method of Ansys Fluent to study the effect of different water supply parameters on the concrete radiant roof’s heat transfer performance, temperature uniformity analysis, and anti-condensation temperature control strategy. The accuracy of the simulation model was verified by comparing the numerical simulation values and measured values of temperature monitoring points. In thermal performance research, the inlet temperature significantly impacted the cooling capacity and radiant surface temperature compared with the inlet flow velocity. In the uniformity study, the distance between the serpentine pipes area and the concrete edge was easily neglected, which was also an important factor affecting the distribution of temperature uniformity. Regarding anti-condensation and performance improvement research, first supplying water at low temperatures and then dynamically adjusting high-temperature water could effectively avoid condensation and improve the radiant roof’s heat transfer performance. The research results could provide technical references for the practical application of radiation roof anti-condensation temperature control technology.

Suggested Citation

  • Bobo Zhang & Qin Sun & Lin Su & Kaijun Dong & Weimin Luo & Haifeng Guan & Zhenhua Shao & Wei Wu, 2023. "Anti-Condensation Temperature Control Strategy of the Concrete Radiant Roof," Energies, MDPI, vol. 16(12), pages 1-14, June.
  • Handle: RePEc:gam:jeners:v:16:y:2023:i:12:p:4826-:d:1175296
    as

    Download full text from publisher

    File URL: https://www.mdpi.com/1996-1073/16/12/4826/pdf
    Download Restriction: no

    File URL: https://www.mdpi.com/1996-1073/16/12/4826/
    Download Restriction: no
    ---><---

    References listed on IDEAS

    as
    1. Zhang, L.Z., 2006. "Energy performance of independent air dehumidification systems with energy recovery measures," Energy, Elsevier, vol. 31(8), pages 1228-1242.
    2. Hout, Mohamad & Ghaddar, Nesreen & Ghali, Kamel & Ismail, Nagham & Simonetti, Marco & Fracastoro, Gian Vincenzo & Virgone, Joseph & Zoughaib, Assaad, 2017. "Displacement ventilation with cooled liquid desiccant dehumidification membrane at ceiling; modeling and design charts," Energy, Elsevier, vol. 139(C), pages 1003-1015.
    Full references (including those not matched with items on IDEAS)

    Most related items

    These are the items that most often cite the same works as this one and are cited by the same works as this one.
    1. Lu, Hao & Lu, Lin & Luo, Yimo & Qi, Ronghui, 2016. "Investigation on the dynamic characteristics of the counter-current flow for liquid desiccant dehumidification," Energy, Elsevier, vol. 101(C), pages 229-238.
    2. De Antonellis, Stefano & Joppolo, Cesare Maria & Molinaroli, Luca & Pasini, Alberto, 2012. "Simulation and energy efficiency analysis of desiccant wheel systems for drying processes," Energy, Elsevier, vol. 37(1), pages 336-345.
    3. Zhang, Tao & Liu, Xiaohua & Jiang, Yi, 2014. "Development of temperature and humidity independent control (THIC) air-conditioning systems in China—A review," Renewable and Sustainable Energy Reviews, Elsevier, vol. 29(C), pages 793-803.
    4. Liu, Hongdou & Yang, Hongquan & Qi, Ronghui, 2020. "A review of electrically driven dehumidification technology for air-conditioning systems," Applied Energy, Elsevier, vol. 279(C).
    5. Duan, Zhiyin & Zhan, Changhong & Zhang, Xingxing & Mustafa, Mahmud & Zhao, Xudong & Alimohammadisagvand, Behrang & Hasan, Ala, 2012. "Indirect evaporative cooling: Past, present and future potentials," Renewable and Sustainable Energy Reviews, Elsevier, vol. 16(9), pages 6823-6850.
    6. Xu, Peng & Ma, Xiaoli & Zhao, Xudong & Fancey, Kevin, 2017. "Experimental investigation of a super performance dew point air cooler," Applied Energy, Elsevier, vol. 203(C), pages 761-777.
    7. Ruivo, Celestino R. & Goldsworthy, Mark & Intini, Manuel, 2014. "Interpolation methods to predict the influence of inlet airflow states on desiccant wheel performance at low regeneration temperature," Energy, Elsevier, vol. 68(C), pages 765-772.
    8. Açıkkalp, Emin & Caliskan, Hakan & Hong, Hiki & Piao, Hongjie & Seung, Dohyun, 2022. "Extended exergy analysis of a photovoltaic-thermal (PVT) module based desiccant air cooling system for buildings," Applied Energy, Elsevier, vol. 323(C).
    9. Yang, C.M. & Chen, C.C. & Chen, S.L., 2013. "Energy-efficient air conditioning system with combination of radiant cooling and periodic total heat exchanger," Energy, Elsevier, vol. 59(C), pages 467-477.
    10. Li, Guo-Pei & Zhang, Li-Zhi, 2016. "Investigation of a solar energy driven and hollow fiber membrane-based humidification–dehumidification desalination system," Applied Energy, Elsevier, vol. 177(C), pages 393-408.
    11. Ge, Gaoming & Xiao, Fu & Xu, Xinhua, 2011. "Model-based optimal control of a dedicated outdoor air-chilled ceiling system using liquid desiccant and membrane-based total heat recovery," Applied Energy, Elsevier, vol. 88(11), pages 4180-4190.
    12. Ge, T.S. & Dai, Y.J. & Wang, R.Z. & Li, Y., 2008. "Experimental investigation on a one-rotor two-stage rotary desiccant cooling system," Energy, Elsevier, vol. 33(12), pages 1807-1815.
    13. Liu, Di & Zhao, Fu-Yun & Tang, Guang-Fa, 2010. "Active low-grade energy recovery potential for building energy conservation," Renewable and Sustainable Energy Reviews, Elsevier, vol. 14(9), pages 2736-2747, December.
    14. Cuce, Pinar Mert & Riffat, Saffa, 2015. "A comprehensive review of heat recovery systems for building applications," Renewable and Sustainable Energy Reviews, Elsevier, vol. 47(C), pages 665-682.
    15. Singh, Ashutosh & Kumar, Sunil & Dev, Rahul, 2019. "Studies on cocopeat, sawdust and dried cow dung as desiccant for evaporative cooling system," Renewable Energy, Elsevier, vol. 142(C), pages 295-303.
    16. Mardiana, A. & Riffat, S.B., 2013. "Review on physical and performance parameters of heat recovery systems for building applications," Renewable and Sustainable Energy Reviews, Elsevier, vol. 28(C), pages 174-190.
    17. Mardiana-Idayu, A. & Riffat, S.B., 2012. "Review on heat recovery technologies for building applications," Renewable and Sustainable Energy Reviews, Elsevier, vol. 16(2), pages 1241-1255.
    18. Liu, Yuting & Li, Jun Ming & Yang, Xu & Zhao, Xudong, 2019. "Two-dimensional numerical study of a heat and mass exchanger for a dew-point evaporative cooler," Energy, Elsevier, vol. 168(C), pages 975-988.
    19. Xiao, Fu & Ge, Gaoming & Niu, Xiaofeng, 2011. "Control performance of a dedicated outdoor air system adopting liquid desiccant dehumidification," Applied Energy, Elsevier, vol. 88(1), pages 143-149, January.
    20. Chen, Wanhe & Yin, Yonggao & Zhao, Xingwang & Fan, Fangsu & Cao, Bowen & Ji, Qiang & Xu, Guoying, 2023. "Sepiolite based humidity-control coating specially for alleviate the condensation problem of radiant cooling panel," Energy, Elsevier, vol. 272(C).

    Corrections

    All material on this site has been provided by the respective publishers and authors. You can help correct errors and omissions. When requesting a correction, please mention this item's handle: RePEc:gam:jeners:v:16:y:2023:i:12:p:4826-:d:1175296. See general information about how to correct material in RePEc.

    If you have authored this item and are not yet registered with RePEc, we encourage you to do it here. This allows to link your profile to this item. It also allows you to accept potential citations to this item that we are uncertain about.

    If CitEc recognized a bibliographic reference but did not link an item in RePEc to it, you can help with this form .

    If you know of missing items citing this one, you can help us creating those links by adding the relevant references in the same way as above, for each refering item. If you are a registered author of this item, you may also want to check the "citations" tab in your RePEc Author Service profile, as there may be some citations waiting for confirmation.

    For technical questions regarding this item, or to correct its authors, title, abstract, bibliographic or download information, contact: MDPI Indexing Manager (email available below). General contact details of provider: https://www.mdpi.com .

    Please note that corrections may take a couple of weeks to filter through the various RePEc services.

    IDEAS is a RePEc service. RePEc uses bibliographic data supplied by the respective publishers.