IDEAS home Printed from https://ideas.repec.org/a/eee/renene/v16y1999i1p700-703.html
   My bibliography  Save this article

Analysis and experimental verification of an improved cooling radiator

Author

Listed:
  • Erell, E.
  • Etzion, Y.

Abstract

Roof ponds cooled by nocturnal long wave radiation have often been proposed as a cheap and effective means of providing thermal comfort in buildings in hot-arid locations. Many of the schemes incorporate flat-plate radiators through which the water is circulated at night to be cooled. This paper analyzes the parameters affecting the performance of such a radiator, specifically designed for nocturnal radiative cooling. A cheap, simple and flexible design for a cooling radiator was suggested as a result of the analysis, and tested at the experimental facilities of the Center for Desert Architecture at Sede-Boqer, Israel. The mean nightly cooling output of the radiator - due to the combined effect of radiation and convection - was over 90 watts/m2 under typical desert meteorological conditions. The analytical model adapted for this application allows accurate calculation of the fluid temperature at the outlet of the radiator, as a function of the properties of the radiator, the meteorological conditions and the operating parameters of the cooling system.

Suggested Citation

  • Erell, E. & Etzion, Y., 1999. "Analysis and experimental verification of an improved cooling radiator," Renewable Energy, Elsevier, vol. 16(1), pages 700-703.
  • Handle: RePEc:eee:renene:v:16:y:1999:i:1:p:700-703
    DOI: 10.1016/S0960-1481(98)00255-9
    as

    Download full text from publisher

    File URL: http://www.sciencedirect.com/science/article/pii/S0960148198002559
    Download Restriction: Full text for ScienceDirect subscribers only

    File URL: https://libkey.io/10.1016/S0960-1481(98)00255-9?utm_source=ideas
    LibKey link: if access is restricted and if your library uses this service, LibKey will redirect you to where you can use your library subscription to access this item
    ---><---

    As the access to this document is restricted, you may want to search for a different version of it.

    Citations

    Citations are extracted by the CitEc Project, subscribe to its RSS feed for this item.
    as


    Cited by:

    1. Amir, A. & van Hout, R., 2019. "A transient model for optimizing a hybrid nocturnal sky radiation cooling system," Renewable Energy, Elsevier, vol. 132(C), pages 370-380.
    2. Karl-Villem Võsa & Andrea Ferrantelli & Jarek Kurnitski, 2022. "Cooling Thermal Comfort and Efficiency Parameters of Ceiling Panels, Underfloor Cooling, Fan-Assisted Radiators, and Fan Coil," Energies, MDPI, vol. 15(11), pages 1-19, June.
    3. Gopalakrishna Gangisetty & Ron Zevenhoven, 2023. "A Review of Nanoparticle Material Coatings in Passive Radiative Cooling Systems Including Skylights," Energies, MDPI, vol. 16(4), pages 1-59, February.
    4. Rachana Vidhi, 2018. "A Review of Underground Soil and Night Sky as Passive Heat Sink: Design Configurations and Models," Energies, MDPI, vol. 11(11), pages 1-24, October.
    5. Vall, Sergi & Castell, Albert, 2017. "Radiative cooling as low-grade energy source: A literature review," Renewable and Sustainable Energy Reviews, Elsevier, vol. 77(C), pages 803-820.
    6. Lu, Xing & Xu, Peng & Wang, Huilong & Yang, Tao & Hou, Jin, 2016. "Cooling potential and applications prospects of passive radiative cooling in buildings: The current state-of-the-art," Renewable and Sustainable Energy Reviews, Elsevier, vol. 65(C), pages 1079-1097.
    7. Cui, Yong & Wang, Yiping & Huang, Qunwu & Wei, Shichao, 2016. "Effect of radiation and convection heat transfer on cooling performance of radiative panel," Renewable Energy, Elsevier, vol. 99(C), pages 10-17.
    8. Ahmad, Irshad, 2010. "Performance of antisolar insulated roof system," Renewable Energy, Elsevier, vol. 35(1), pages 36-41.
    9. Man, Yi & Yang, Hongxing & Spitler, Jeffrey D. & Fang, Zhaohong, 2011. "Feasibility study on novel hybrid ground coupled heat pump system with nocturnal cooling radiator for cooling load dominated buildings," Applied Energy, Elsevier, vol. 88(11), pages 4160-4171.

    Corrections

    All material on this site has been provided by the respective publishers and authors. You can help correct errors and omissions. When requesting a correction, please mention this item's handle: RePEc:eee:renene:v:16:y:1999:i:1:p:700-703. See general information about how to correct material in RePEc.

    If you have authored this item and are not yet registered with RePEc, we encourage you to do it here. This allows to link your profile to this item. It also allows you to accept potential citations to this item that we are uncertain about.

    We have no bibliographic references for this item. You can help adding them by using this form .

    If you know of missing items citing this one, you can help us creating those links by adding the relevant references in the same way as above, for each refering item. If you are a registered author of this item, you may also want to check the "citations" tab in your RePEc Author Service profile, as there may be some citations waiting for confirmation.

    For technical questions regarding this item, or to correct its authors, title, abstract, bibliographic or download information, contact: Catherine Liu (email available below). General contact details of provider: http://www.journals.elsevier.com/renewable-energy .

    Please note that corrections may take a couple of weeks to filter through the various RePEc services.

    IDEAS is a RePEc service. RePEc uses bibliographic data supplied by the respective publishers.