IDEAS home Printed from https://ideas.repec.org/a/eee/renene/v10y1997i2p403-408.html
   My bibliography  Save this article

Direct heat utilization of geothermal resources

Author

Listed:
  • Lund, John W.

Abstract

Direct utilization of geothermal energy consists of various forms for heating and cooling instead of converting the energy for electric power generation. The major areas of direct utilization are (1) swimming, bathing and balneology, (2) space heating and cooling including district heating, (3) agriculture applications, (4) aquaculture applications, (5) industrial processes, and (6) heat pumps. Major direct utilization projects exploiting geothermal energy exist in about 38 countries, and the estimated installed thermal power is almost 9,000 MWt utilizing 37,000 kg/s of fluid. The world-wide thermal energy used is estimated to be at least 108,100 TJ/yr (30,000 GWh/yr) - saving 3.65 million TOE/yr. The majority of this energy use is for space heating (33%), and swimming and bathing (19%). In the USA the installed thermal power is 1874 MWt, and the annual energy use is 13,890 TJ (3,860 GWh). The majority of the use (59 %) is for heat pumps (both ground coupled and water source), with space heating, bathing and swimming, and fish and animal farming each supplying about 10%.

Suggested Citation

  • Lund, John W., 1997. "Direct heat utilization of geothermal resources," Renewable Energy, Elsevier, vol. 10(2), pages 403-408.
  • Handle: RePEc:eee:renene:v:10:y:1997:i:2:p:403-408
    DOI: 10.1016/0960-1481(96)00097-3
    as

    Download full text from publisher

    File URL: http://www.sciencedirect.com/science/article/pii/0960148196000973
    Download Restriction: Full text for ScienceDirect subscribers only

    File URL: https://libkey.io/10.1016/0960-1481(96)00097-3?utm_source=ideas
    LibKey link: if access is restricted and if your library uses this service, LibKey will redirect you to where you can use your library subscription to access this item
    ---><---

    As the access to this document is restricted, you may want to search for a different version of it.

    Citations

    Citations are extracted by the CitEc Project, subscribe to its RSS feed for this item.
    as


    Cited by:

    1. Blum, Philipp & Campillo, Gisela & Münch, Wolfram & Kölbel, Thomas, 2010. "CO2 savings of ground source heat pump systems – A regional analysis," Renewable Energy, Elsevier, vol. 35(1), pages 122-127.
    2. Jana Lippelt & Johannes Pfeiffer & Michael Kunz, 2010. "Kurz zum Klima: Rettung aus der Tiefe?," ifo Schnelldienst, ifo Institute - Leibniz Institute for Economic Research at the University of Munich, vol. 63(17), pages 30-33, September.
    3. Nakomcic-Smaragdakis, Branka & Dvornic, Tijana & Cepic, Zoran & Dragutinovic, Natasa, 2016. "Analysis and possible geothermal energy utilization in a municipality of Panonian Basin of Serbia," Renewable and Sustainable Energy Reviews, Elsevier, vol. 59(C), pages 940-951.
    4. Choi, Jung Chan & Park, Joonsang & Lee, Seung Rae, 2013. "Numerical evaluation of the effects of groundwater flow on borehole heat exchanger arrays," Renewable Energy, Elsevier, vol. 52(C), pages 230-240.
    5. Chao Yu & Tian Tian & Chengyu Hui & Haochen Huang & Yiqun Zhang, 2022. "Study on Unblocking and Permeability Enhancement Technology with Rotary Water Jet for Low Recharge Efficiency Wells in Sandstone Geothermal Reservoirs," Energies, MDPI, vol. 15(24), pages 1-21, December.
    6. Karytsas, Spyridon & Choropanitis, Ioannis, 2017. "Barriers against and actions towards renewable energy technologies diffusion: A Principal Component Analysis for residential ground source heat pump (GSHP) systems," Renewable and Sustainable Energy Reviews, Elsevier, vol. 78(C), pages 252-271.
    7. Javier F. Urchueguía & Lenin-Guillermo Lemus-Zúñiga & Jose-Vicente Oliver-Villanueva & Borja Badenes & Miguel A. Mateo Pla & José Manuel Cuevas, 2018. "How Reliable Are Standard Thermal Response Tests? An Assessment Based on Long-Term Thermal Response Tests Under Different Operational Conditions," Energies, MDPI, vol. 11(12), pages 1-24, November.

    Corrections

    All material on this site has been provided by the respective publishers and authors. You can help correct errors and omissions. When requesting a correction, please mention this item's handle: RePEc:eee:renene:v:10:y:1997:i:2:p:403-408. See general information about how to correct material in RePEc.

    If you have authored this item and are not yet registered with RePEc, we encourage you to do it here. This allows to link your profile to this item. It also allows you to accept potential citations to this item that we are uncertain about.

    We have no bibliographic references for this item. You can help adding them by using this form .

    If you know of missing items citing this one, you can help us creating those links by adding the relevant references in the same way as above, for each refering item. If you are a registered author of this item, you may also want to check the "citations" tab in your RePEc Author Service profile, as there may be some citations waiting for confirmation.

    For technical questions regarding this item, or to correct its authors, title, abstract, bibliographic or download information, contact: Catherine Liu (email available below). General contact details of provider: http://www.journals.elsevier.com/renewable-energy .

    Please note that corrections may take a couple of weeks to filter through the various RePEc services.

    IDEAS is a RePEc service. RePEc uses bibliographic data supplied by the respective publishers.