IDEAS home Printed from https://ideas.repec.org/a/eee/energy/v156y2018icp725-749.html
   My bibliography  Save this article

A comprehensive review of the Maisotsenko-cycle based air conditioning systems

Author

Listed:
  • Sadighi Dizaji, Hamed
  • Hu, Eric Jing
  • Chen, Lei

Abstract

Maisotsenko cycle (M-cycle) is a promising air cooling technique which can reduce the temperature of air flow until dew point which was not possible either in direct contact techniques or former indirect evaporative methods. M-cycle systems have been employed previously on gas turbines, air conditioning systems, cooling towers, electronic cooling etc. Simultaneous consideration of all of them prevents detailed presentation. For that reason and because of the wide application of air conditioning systems, this paper focuses only on the use of M-cycle on air conditioning systems. Moreover, former types of indirect evaporative air coolers which do not work based on Maisotsenko cycle are not considered in the present study. Researchers have evaluated the M-cycle characteristics via different methods including analytical solution, numerical simulation, statistical design methods and experimental-techniques all of which is divided into several categories as well. All said methods are organizedly discussed and compared in this paper. It has been tried to provide an evolutionary viewpoint for analytical solutions of M-cycle. Thus, analytical solutions were reorganized with unique abbreviations in order to become more understandable and comparable with each other. All M-cycle parameters (which have been analyzed via numerical or experimental ways) are coherently systematized and then a comprehensive-compact view of obtained results is presented. Finally, the current status of M-cycle industry is summarized and the future research direction on M-cycle is proposed.

Suggested Citation

  • Sadighi Dizaji, Hamed & Hu, Eric Jing & Chen, Lei, 2018. "A comprehensive review of the Maisotsenko-cycle based air conditioning systems," Energy, Elsevier, vol. 156(C), pages 725-749.
  • Handle: RePEc:eee:energy:v:156:y:2018:i:c:p:725-749
    DOI: 10.1016/j.energy.2018.05.086
    as

    Download full text from publisher

    File URL: http://www.sciencedirect.com/science/article/pii/S036054421830906X
    Download Restriction: Full text for ScienceDirect subscribers only

    File URL: https://libkey.io/10.1016/j.energy.2018.05.086?utm_source=ideas
    LibKey link: if access is restricted and if your library uses this service, LibKey will redirect you to where you can use your library subscription to access this item
    ---><---

    As the access to this document is restricted, you may want to search for a different version of it.

    Citations

    Citations are extracted by the CitEc Project, subscribe to its RSS feed for this item.
    as


    Cited by:

    1. Shahzad, Muhammad Wakil & Burhan, Muhammad & Ybyraiymkul, Doskhan & Oh, Seung Jin & Ng, Kim Choon, 2019. "An improved indirect evaporative cooler experimental investigation," Applied Energy, Elsevier, vol. 256(C).
    2. Zanchini, Enzo & Naldi, Claudia, 2019. "Energy saving obtainable by applying a commercially available M-cycle evaporative cooling system to the air conditioning of an office building in North Italy," Energy, Elsevier, vol. 179(C), pages 975-988.
    3. Yan, Weichao & Cui, Xin & Meng, Xiangzhao & Yang, Chuanjun & Liu, Yilin & An, Hui & Jin, Liwen, 2023. "Effect of random fiber distribution on the performance of counter-flow hollow fiber membrane-based direct evaporative coolers," Energy, Elsevier, vol. 282(C).
    4. Cui, Xin & Yan, Weichao & Liu, Yilin & Zhao, Min & Jin, Liwen, 2020. "Performance analysis of a hollow fiber membrane-based heat and mass exchanger for evaporative cooling," Applied Energy, Elsevier, vol. 271(C).
    5. Xin Cui & Le Sun & Sicong Zhang & Liwen Jin, 2019. "On the Study of a Hybrid Indirect Evaporative Pre-Cooling System for Various Climates," Energies, MDPI, vol. 12(23), pages 1-16, November.
    6. Sadighi Dizaji, Hamed & Hu, Eric Jing & Chen, Lei & Pourhedayat, Samira, 2018. "Development and validation of an analytical model for perforated (multi-stage) regenerative M-cycle air cooler," Applied Energy, Elsevier, vol. 228(C), pages 2176-2194.
    7. Zhu, Guangya & Wen, Tao & Wang, Qunwei & Xu, Xiaoyu, 2022. "A review of dew-point evaporative cooling: Recent advances and future development," Applied Energy, Elsevier, vol. 312(C).
    8. Tariq, Rasikh & Sheikh, Nadeem Ahmed & Livas-García, A. & Xamán, J. & Bassam, A. & Maisotsenko, Valeriy, 2021. "Projecting global water footprints diminution of a dew-point cooling system: Sustainability approach assisted with energetic and economic assessment," Renewable and Sustainable Energy Reviews, Elsevier, vol. 140(C).
    9. Pourhedayat, Samira & Hu, Eric & Chen, Lei, 2022. "Simulation of innovative hybridizing M-cycle cooler and absorption-refrigeration for pre-cooling of gas turbine intake air: Including a case study for Siemens SGT-750 gas turbine," Energy, Elsevier, vol. 247(C).
    10. Sadighi Dizaji, Hamed & Hu, Eric Jing & Chen, Lei & Pourhedayat, Samira, 2020. "Analytical/experimental sensitivity study of key design and operational parameters of perforated Maisotsenko cooler based on novel wet-surface theory," Applied Energy, Elsevier, vol. 262(C).
    11. Lanbo Lai & Xiaolin Wang & Gholamreza Kefayati & Eric Hu, 2021. "Evaporative Cooling Integrated with Solid Desiccant Systems: A Review," Energies, MDPI, vol. 14(18), pages 1-23, September.
    12. De Paepe, Ward & Pappa, Alessio & Montero Carrero, Marina & Bricteux, Laurent & Contino, Francesco, 2020. "Reducing waste heat to the minimum: Thermodynamic assessment of the M-power cycle concept applied to micro Gas Turbines," Applied Energy, Elsevier, vol. 279(C).
    13. Xiao, Xin & Liu, Jinjin, 2024. "A state-of-art review of dew point evaporative cooling technology and integrated applications," Renewable and Sustainable Energy Reviews, Elsevier, vol. 191(C).
    14. Jing Lv & Bo Zhou & Mengya Zhu & Wenhao Xi & Eric Hu, 2022. "Experimental Study on the Performance of a Dew-Point Evaporative Cooling System with a Nanoporous Membrane," Energies, MDPI, vol. 15(7), pages 1-17, April.
    15. Pandelidis, Demis & Cichoń, Aleksandra & Pacak, Anna & Anisimov, Sergey & Drąg, Paweł, 2018. "Counter-flow indirect evaporative cooler for heat recovery in the temperate climate," Energy, Elsevier, vol. 165(PA), pages 877-894.

    Corrections

    All material on this site has been provided by the respective publishers and authors. You can help correct errors and omissions. When requesting a correction, please mention this item's handle: RePEc:eee:energy:v:156:y:2018:i:c:p:725-749. See general information about how to correct material in RePEc.

    If you have authored this item and are not yet registered with RePEc, we encourage you to do it here. This allows to link your profile to this item. It also allows you to accept potential citations to this item that we are uncertain about.

    We have no bibliographic references for this item. You can help adding them by using this form .

    If you know of missing items citing this one, you can help us creating those links by adding the relevant references in the same way as above, for each refering item. If you are a registered author of this item, you may also want to check the "citations" tab in your RePEc Author Service profile, as there may be some citations waiting for confirmation.

    For technical questions regarding this item, or to correct its authors, title, abstract, bibliographic or download information, contact: Catherine Liu (email available below). General contact details of provider: http://www.journals.elsevier.com/energy .

    Please note that corrections may take a couple of weeks to filter through the various RePEc services.

    IDEAS is a RePEc service. RePEc uses bibliographic data supplied by the respective publishers.