IDEAS home Printed from https://ideas.repec.org/a/eee/appene/v203y2017icp57-71.html
   My bibliography  Save this article

Modelling of AQI related to building space heating energy demand based on big data analytics

Author

Listed:
  • Li, Han
  • You, Shijun
  • Zhang, Huan
  • Zheng, Wandong
  • Zheng, Xuejing
  • Jia, Jie
  • Ye, Tianzhen
  • Zou, Lanjun

Abstract

According to the annual air quality report released by the Ministry of Environmental Protection of China, the cities that requiring heating reported an average of 168.3days that could not reach the air quality standard, which was 59.8% higher than warm cities that did not require heating in 2014. Coal-fired energy conversion for building space heating can generate a large amount of haze pollutions during the winter. More seriously, the year-by-year data of district heating capacity increases with an average growth rate of 5.59% published in the China Statistical Yearbook, which means more and more heating associated pollutants will emit into the atmosphere and result in the worse and worse environment quality predictability in the further without taking any effective measure. In this context, considering the factors of energy, environment and human health simultaneously, this paper aimed to develop an air quality index (AQI) associated with energy conversion for building space heating model to guide the energy-saving measures on heating. Principal component analysis and grey relation projection evaluation theory approaches were used to preprocess the historical AQI data. Moreover, a simplified two-dimensionality heating capacity model based on EnergyPlus simulation results was introduced to expand the application range of the AQI-Heating (A-H) model. The A-H model included three components, which were the direct pollutant emission, regenerated pollutant emission and urban self-purifying capacity. Four pollutants related input coefficients including the direct emission factor A, the urban maximum purifying capacity a, the attenuation coefficient b and the regenerated coefficient ξ were solved by homemade code based on Matlab software according to a 10-year observed data (2003–2015). The performance of A-H model was compared with the actual values (data from 2015 to 2016) and the results of conventional linear and nonlinear regression techniques, in terms of the index of mean absolute error (MAE), mean absolute percentage error (MAPE), root-mean-squared error (RMSE) and index of agreement (IA). All performance metrics proved that the A-H model was accurate enough (e.g. IA=0.983) to analyze the relationship between the AQI and the energy conversion for building space heating.

Suggested Citation

  • Li, Han & You, Shijun & Zhang, Huan & Zheng, Wandong & Zheng, Xuejing & Jia, Jie & Ye, Tianzhen & Zou, Lanjun, 2017. "Modelling of AQI related to building space heating energy demand based on big data analytics," Applied Energy, Elsevier, vol. 203(C), pages 57-71.
  • Handle: RePEc:eee:appene:v:203:y:2017:i:c:p:57-71
    DOI: 10.1016/j.apenergy.2017.06.002
    as

    Download full text from publisher

    File URL: http://www.sciencedirect.com/science/article/pii/S0306261917307523
    Download Restriction: Full text for ScienceDirect subscribers only

    File URL: https://libkey.io/10.1016/j.apenergy.2017.06.002?utm_source=ideas
    LibKey link: if access is restricted and if your library uses this service, LibKey will redirect you to where you can use your library subscription to access this item
    ---><---

    As the access to this document is restricted, you may want to search for a different version of it.

    References listed on IDEAS

    as
    1. Bianchini, Gianni & Casini, Marco & Vicino, Antonio & Zarrilli, Donato, 2016. "Demand-response in building heating systems: A Model Predictive Control approach," Applied Energy, Elsevier, vol. 168(C), pages 159-170.
    2. Meng, Fanyi & Su, Bin & Thomson, Elspeth & Zhou, Dequn & Zhou, P., 2016. "Measuring China’s regional energy and carbon emission efficiency with DEA models: A survey," Applied Energy, Elsevier, vol. 183(C), pages 1-21.
    3. Tong, Zheming & Chen, Yujiao & Malkawi, Ali & Liu, Zhu & Freeman, Richard B., 2016. "Energy saving potential of natural ventilation in China: The impact of ambient air pollution," Applied Energy, Elsevier, vol. 179(C), pages 660-668.
    4. Chen, Yujiao & Malkawi, Ali & Liu, Zhu & Freeman, Richard Barry & Tong, Zheming, 2016. "Energy Saving Potential of Natural Ventilation in China: The Impact of Ambient Air Pollution," Scholarly Articles 27733689, Harvard University Department of Economics.
    5. Elagib, N.a. & Alvi, S.H. & Mansell, M.G., 1999. "Correlationships between clearness index and relative sunshine duration for Sudan," Renewable Energy, Elsevier, vol. 17(4), pages 473-498.
    6. Dong, Huijuan & Dai, Hancheng & Dong, Liang & Fujita, Tsuyoshi & Geng, Yong & Klimont, Zbigniew & Inoue, Tsuyoshi & Bunya, Shintaro & Fujii, Minoru & Masui, Toshihiko, 2015. "Pursuing air pollutant co-benefits of CO2 mitigation in China: A provincial leveled analysis," Applied Energy, Elsevier, vol. 144(C), pages 165-174.
    7. Zheng, Guozhong & Jing, Youyin & Huang, Hongxia & Gao, Yuefen, 2010. "Application of improved grey relational projection method to evaluate sustainable building envelope performance," Applied Energy, Elsevier, vol. 87(2), pages 710-720, February.
    Full references (including those not matched with items on IDEAS)

    Citations

    Citations are extracted by the CitEc Project, subscribe to its RSS feed for this item.
    as


    Cited by:

    1. Krzysztof Nowak & Sławomir Rabczak, 2020. "Technical and Economic Analysis of the External Surface Heating System on the Example of a Car Park," Energies, MDPI, vol. 13(24), pages 1-15, December.
    2. Van-Hai Bui & Akhtar Hussain & Hak-Man Kim & Yong-Hoon Im, 2018. "Optimal Energy Management of Building Microgrid Networks in Islanded Mode Considering Adjustable Power and Component Outages," Energies, MDPI, vol. 11(9), pages 1-22, September.
    3. Li, Han & Li, Jinchao & Kong, Xiangfei & Long, Hao & Yang, Hua & Yao, Chengqiang, 2020. "A novel solar thermal system combining with active phase-change material heat storage wall (STS-APHSW): Dynamic model, validation and thermal performance," Energy, Elsevier, vol. 201(C).
    4. Liu, Jia-Bao & Zheng, Ya-Qian & Lee, Chien-Chiang, 2024. "Statistical analysis of the regional air quality index of Yangtze River Delta based on complex network theory," Applied Energy, Elsevier, vol. 357(C).
    5. Sorrentino, Marco & Bruno, Marco & Trifirò, Alena & Rizzo, Gianfranco, 2019. "An innovative energy efficiency metric for data analytics and diagnostics in telecommunication applications," Applied Energy, Elsevier, vol. 242(C), pages 1539-1548.
    6. Xuan Yang & Yue Wang & Di Chen & Xue Tan & Xue Tian & Lei Shi, 2021. "Does the “Blue Sky Defense War Policy” Paint the Sky Blue?—A Case Study of Beijing–Tianjin–Hebei Region, China," IJERPH, MDPI, vol. 18(23), pages 1-25, November.
    7. Yani Bao & Wai Ling Lee & Jie Jia, 2018. "Exergy Analyses and Modelling of a Novel Extra-Low Temperature Dedicated Outdoor Air System," Energies, MDPI, vol. 11(5), pages 1-25, May.
    8. Fan, Man & Liang, Hongbo & You, Shijun & Zhang, Huan & Yin, Baoquan & Wu, Xiaoting, 2018. "Applicability analysis of the solar heating system with parabolic trough solar collectors in different regions of China," Applied Energy, Elsevier, vol. 221(C), pages 100-111.
    9. Natasha Frilingou & Demetri Bouris, 2020. "Effects of Building Energy Efficiency Measures on Air Quality at the Neighborhood Level in Athens, Greece," Energies, MDPI, vol. 13(21), pages 1-23, October.
    10. Ning Xu & Fan Zhang & Xin Xuan, 2021. "Impacts of Industrial Restructuring and Technological Progress on PM 2.5 Pollution: Evidence from Prefecture-Level Cities in China," IJERPH, MDPI, vol. 18(10), pages 1-17, May.
    11. Yuan, Meng & Vad Mathiesen, Brian & Schneider, Noémi & Xia, Jianjun & Zheng, Wen & Sorknæs, Peter & Lund, Henrik & Zhang, Lipeng, 2024. "Renewable energy and waste heat recovery in district heating systems in China: A systematic review," Energy, Elsevier, vol. 294(C).
    12. Li, Yang & Wang, Jinlong & Zhao, Dongbo & Li, Guoqing & Chen, Chen, 2018. "A two-stage approach for combined heat and power economic emission dispatch: Combining multi-objective optimization with integrated decision making," Energy, Elsevier, vol. 162(C), pages 237-254.
    13. Qingchen Liu & Xinyi Li & Tao Liu & Xiaojun Zhao, 2020. "Spatio-Temporal Correlation Analysis of Air Quality in China: Evidence from Provincial Capitals Data," Sustainability, MDPI, vol. 12(6), pages 1-21, March.
    14. Li, Han & Fu, Zheng & Xi, Chang & Li, Nana & Li, Wei & Kong, Xiangfei, 2022. "Study on the impact of parallel jet spacing on the performance of multi-jet stratum ventilation," Applied Energy, Elsevier, vol. 306(PB).
    15. Wang, Lu & Yuan, JianJuan & Qiao, Xu & Kong, Xiangfei, 2023. "Optimal rule based double predictive control for the management of thermal energy in a distributed clean heating system," Renewable Energy, Elsevier, vol. 215(C).
    16. Chen, Jing & Zhou, Chunshan & Wang, Shaojian & Li, Shijie, 2018. "Impacts of energy consumption structure, energy intensity, economic growth, urbanization on PM2.5 concentrations in countries globally," Applied Energy, Elsevier, vol. 230(C), pages 94-105.

    Most related items

    These are the items that most often cite the same works as this one and are cited by the same works as this one.
    1. Zhang, Shaohui & Guo, Qinxin & Smyth, Russell & Yao, Yao, 2022. "Extreme temperatures and residential electricity consumption: Evidence from Chinese households," Energy Economics, Elsevier, vol. 107(C).
    2. Liwei Wen & Kyosuke Hiyama, 2018. "Target Air Change Rate and Natural Ventilation Potential Maps for Assisting with Natural Ventilation Design During Early Design Stage in China," Sustainability, MDPI, vol. 10(5), pages 1-16, May.
    3. Wei Xue & Qingming Zhan & Qi Zhang & Zhonghua Wu, 2019. "Spatiotemporal Variations of Particulate and Gaseous Pollutants and Their Relations to Meteorological Parameters: The Case of Xiangyang, China," IJERPH, MDPI, vol. 17(1), pages 1-23, December.
    4. Martins, Nuno R. & Carrilho da Graça, Guilherme, 2017. "Impact of outdoor PM2.5 on natural ventilation usability in California’s nondomestic buildings," Applied Energy, Elsevier, vol. 189(C), pages 711-724.
    5. Payam Nejat & Fatemeh Jomehzadeh & Hasanen Mohammed Hussen & John Kaiser Calautit & Muhd Zaimi Abd Majid, 2018. "Application of Wind as a Renewable Energy Source for Passive Cooling through Windcatchers Integrated with Wing Walls," Energies, MDPI, vol. 11(10), pages 1-23, September.
    6. Qing He & Haiyang Zhao & Lin Shen & Liuqun Dong & Ye Cheng & Ke Xu, 2019. "Factors Influencing Residents’ Intention toward Green Retrofitting of Existing Residential Buildings," Sustainability, MDPI, vol. 11(15), pages 1-23, August.
    7. Ádám László Katona & Huang Xuan & Sara Elhadad & István Kistelegdi & István Háber, 2020. "High-Resolution CFD and In-Situ Monitoring Based Validation of an Industrial Passive Air Conduction System (PACS)," Energies, MDPI, vol. 13(12), pages 1-23, June.
    8. Alberto Meiss & Miguel A. Padilla-Marcos & Jesús Feijó-Muñoz, 2017. "Methodology Applied to the Evaluation of Natural Ventilation in Residential Building Retrofits: A Case Study," Energies, MDPI, vol. 10(4), pages 1-19, April.
    9. Chen, Yujiao & Tong, Zheming & Wu, Wentao & Samuelson, Holly & Malkawi, Ali & Norford, Leslie, 2019. "Achieving natural ventilation potential in practice: Control schemes and levels of automation," Applied Energy, Elsevier, vol. 235(C), pages 1141-1152.
    10. Fan, Yuling & Xia, Xiaohua, 2018. "Building retrofit optimization models using notch test data considering energy performance certificate compliance," Applied Energy, Elsevier, vol. 228(C), pages 2140-2152.
    11. Jian Sun & Jianguo Li & Yuanli Liu & Zhijie Huang & Jinghui Cai, 2021. "A Novel Oil-free Dual Piston Compressor Driven by a Moving Coil Linear Motor with Capacity Regulation Using R134a," Sustainability, MDPI, vol. 13(9), pages 1-21, April.
    12. Elaouzy, Y. & El Fadar, A., 2022. "Energy, economic and environmental benefits of integrating passive design strategies into buildings: A review," Renewable and Sustainable Energy Reviews, Elsevier, vol. 167(C).
    13. Yun-Yi Zhang & Kai Kang & Jia-Rui Lin & Jian-Ping Zhang & Yi Zhang, 2020. "Building information modeling–based cyber-physical platform for building performance monitoring," International Journal of Distributed Sensor Networks, , vol. 16(2), pages 15501477209, February.
    14. Tong, Zheming & Chen, Yujiao & Malkawi, Ali, 2017. "Estimating natural ventilation potential for high-rise buildings considering boundary layer meteorology," Applied Energy, Elsevier, vol. 193(C), pages 276-286.
    15. Yu, Bendong & Yang, Jichun & He, Wei & Qin, Minghui & Zhao, Xudong & Chen, Hongbing, 2019. "The performance analysis of a novel hybrid solar gradient utilization photocatalytic-thermal-catalytic-Trombe wall system," Energy, Elsevier, vol. 174(C), pages 420-435.
    16. Song, Zhe & Liu, Jia & Yang, Hongxing, 2021. "Air pollution and soiling implications for solar photovoltaic power generation: A comprehensive review," Applied Energy, Elsevier, vol. 298(C).
    17. Xiaoyun Zhang & Yu Wang & Jie Bao & Tengda Wei & Shiwei Xu, 2022. "A Research on the Evaluation of China’s Food Security under the Perspective of Sustainable Development—Based on an Entropy Weight TOPSIS Model," Agriculture, MDPI, vol. 12(11), pages 1-19, November.
    18. Zhang, Chaobo & Xue, Xue & Zhao, Yang & Zhang, Xuejun & Li, Tingting, 2019. "An improved association rule mining-based method for revealing operational problems of building heating, ventilation and air conditioning (HVAC) systems," Applied Energy, Elsevier, vol. 253(C), pages 1-1.
    19. Sulfiah Dwi Astarini & Christiono Utomo, 2020. "Performance-Based Building Design of High-Rise Residential Buildings in Indonesia," Sustainability, MDPI, vol. 12(17), pages 1-17, August.
    20. Yu, Bendong & He, Wei & Li, Niansi & Wang, Liping & Cai, Jingyong & Chen, Hongbing & Ji, Jie & Xu, Gang, 2017. "Experimental and numerical performance analysis of a TC-Trombe wall," Applied Energy, Elsevier, vol. 206(C), pages 70-82.

    Corrections

    All material on this site has been provided by the respective publishers and authors. You can help correct errors and omissions. When requesting a correction, please mention this item's handle: RePEc:eee:appene:v:203:y:2017:i:c:p:57-71. See general information about how to correct material in RePEc.

    If you have authored this item and are not yet registered with RePEc, we encourage you to do it here. This allows to link your profile to this item. It also allows you to accept potential citations to this item that we are uncertain about.

    If CitEc recognized a bibliographic reference but did not link an item in RePEc to it, you can help with this form .

    If you know of missing items citing this one, you can help us creating those links by adding the relevant references in the same way as above, for each refering item. If you are a registered author of this item, you may also want to check the "citations" tab in your RePEc Author Service profile, as there may be some citations waiting for confirmation.

    For technical questions regarding this item, or to correct its authors, title, abstract, bibliographic or download information, contact: Catherine Liu (email available below). General contact details of provider: http://www.elsevier.com/wps/find/journaldescription.cws_home/405891/description#description .

    Please note that corrections may take a couple of weeks to filter through the various RePEc services.

    IDEAS is a RePEc service. RePEc uses bibliographic data supplied by the respective publishers.