IDEAS home Printed from https://ideas.repec.org/a/eee/appene/v185y2017ip2p1585-1594.html
   My bibliography  Save this article

Experimental performance evaluation of solid concrete and dry insulation materials for passive buildings in hot and humid climatic conditions

Author

Listed:
  • Rehman, Hassam Ur

Abstract

It is known that enhancement of building energy efficiency can help in reducing energy consumption. The use of the solar insulating materials are the most efficient and cost effective passive methods for reducing the cooling requirements of the buildings. Apart from theoretical studies, no detailed experimental studies were performed in the UAE on energy savings by using solar insulation materials on buildings. Four (3m×3m×3m) solar calorimeters were built in RAK, UAE in order to perform an open air outdoor test for energy savings obtained with solar insulating materials. The design is aimed to determine the heat flux reduction and the energy savings achieved with and without different solar insulating materials, mounted at the south wall of solar calorimeters with similar indoor and ambient conditions. Experimental results are discussed to evaluate the thermal performance during high temperature conditions in summer’s period when cooling demand of the building is at its peak and also in winters when there is no cooling demand. The test is from 2012 to 2014. The controlled-temperature experimental study at a set point of 24°C showed that if the standard building material, i.e. solid concrete, is retrofitted with polyisocyanurate (PIR) and reflective coatings or completely replaced with energy-efficient dry insulation material walls such as exterior insulation finishing system (EIFS), energy savings up to an average of 7.6–25.3% can be achieved. This is due to the reduction of heat flux by an average of 22–75% at south wall during summer. Similarly, free floating analysis was done during winter and the measurements showed the behaviour of the heat flux flow and the variations in room temperature due to the variation of thermal mass caused by the difference in heat capacities of the façade with and without insulation. Heat flux and temperature variations were minimal in cases of insulated buildings when compared against a reference building in the winter free flow tests. The temperature variation is limited to 2°C in case of insulated buildings compared to 6°C in the reference case caused by high thermal inertia. Thus, insulation is essential in summer as well as in winter for the buildings in Middle East and North Africa (MENA). Overall, this paper provides a novel view on the most significant contributors to the thermal behaviour of the structure, and presents a methodology on the outdoor tests with various materials, that can significantly improve the thermal behaviour of the buildings in the extremely hot climate.

Suggested Citation

  • Rehman, Hassam Ur, 2017. "Experimental performance evaluation of solid concrete and dry insulation materials for passive buildings in hot and humid climatic conditions," Applied Energy, Elsevier, vol. 185(P2), pages 1585-1594.
  • Handle: RePEc:eee:appene:v:185:y:2017:i:p2:p:1585-1594
    DOI: 10.1016/j.apenergy.2016.01.026
    as

    Download full text from publisher

    File URL: http://www.sciencedirect.com/science/article/pii/S030626191630006X
    Download Restriction: Full text for ScienceDirect subscribers only

    File URL: https://libkey.io/10.1016/j.apenergy.2016.01.026?utm_source=ideas
    LibKey link: if access is restricted and if your library uses this service, LibKey will redirect you to where you can use your library subscription to access this item
    ---><---

    As the access to this document is restricted, you may want to search for a different version of it.

    References listed on IDEAS

    as
    1. Ascione, Fabrizio & Bianco, Nicola & De Masi, Rosa Francesca & de’ Rossi, Filippo & Vanoli, Giuseppe Peter, 2014. "Energy refurbishment of existing buildings through the use of phase change materials: Energy savings and indoor comfort in the cooling season," Applied Energy, Elsevier, vol. 113(C), pages 990-1007.
    2. Nussbaumer, T. & Wakili, K. Ghazi & Tanner, Ch., 2006. "Experimental and numerical investigation of the thermal performance of a protected vacuum-insulation system applied to a concrete wall," Applied Energy, Elsevier, vol. 83(8), pages 841-855, August.
    3. Al-Iriani, Mahmoud A., 2005. "Climate-related electricity demand-side management in oil-exporting countries--the case of the United Arab Emirates," Energy Policy, Elsevier, vol. 33(18), pages 2350-2360, December.
    4. Kazim, Ayoub M., 2007. "Assessments of primary energy consumption and its environmental consequences in the United Arab Emirates," Renewable and Sustainable Energy Reviews, Elsevier, vol. 11(3), pages 426-446, April.
    5. Radhi, Hassan & Eltrapolsi, Ali & Sharples, Stephen, 2009. "Will energy regulations in the Gulf States make buildings more comfortable - A scoping study of residential buildings," Applied Energy, Elsevier, vol. 86(12), pages 2531-2539, December.
    6. Al-Ajlan, S.A. & Al-Ibrahim, A.M. & Abdulkhaleq, M. & Alghamdi, F., 2006. "Developing sustainable energy policies for electrical energy conservation in Saudi Arabia," Energy Policy, Elsevier, vol. 34(13), pages 1556-1565, September.
    7. Al-Sanea, Sami A. & Zedan, M.F. & Al-Hussain, S.N., 2013. "Effect of masonry material and surface absorptivity on critical thermal mass in insulated building walls," Applied Energy, Elsevier, vol. 102(C), pages 1063-1070.
    8. Ihara, Takeshi & Gustavsen, Arild & Jelle, Bjørn Petter, 2015. "Effect of facade components on energy efficiency in office buildings," Applied Energy, Elsevier, vol. 158(C), pages 422-432.
    9. Meissner, José W. & Abadie, Marc O. & Moura, Luís M. & Mendonça, Kátia C. & Mendes, Nathan, 2014. "Performance curves of room air conditioners for building energy simulation tools," Applied Energy, Elsevier, vol. 129(C), pages 243-252.
    10. Bond, Danielle E.M. & Clark, William W. & Kimber, Mark, 2013. "Configuring wall layers for improved insulation performance," Applied Energy, Elsevier, vol. 112(C), pages 235-245.
    11. Lundström, Lukas & Wallin, Fredrik, 2016. "Heat demand profiles of energy conservation measures in buildings and their impact on a district heating system," Applied Energy, Elsevier, vol. 161(C), pages 290-299.
    12. Ucar, Aynur & Balo, Figen, 2009. "Effect of fuel type on the optimum thickness of selected insulation materials for the four different climatic regions of Turkey," Applied Energy, Elsevier, vol. 86(5), pages 730-736, May.
    13. Radhi, H., 2009. "Can envelope codes reduce electricity and CO2 emissions in different types of buildings in the hot climate of Bahrain?," Energy, Elsevier, vol. 34(2), pages 205-215.
    14. Lee, Kyoung Ok & Medina, Mario A. & Raith, Erik & Sun, Xiaoqin, 2015. "Assessing the integration of a thin phase change material (PCM) layer in a residential building wall for heat transfer reduction and management," Applied Energy, Elsevier, vol. 137(C), pages 699-706.
    15. Gruber, Mattias & Trüschel, Anders & Dalenbäck, Jan-Olof, 2015. "Energy efficient climate control in office buildings without giving up implementability," Applied Energy, Elsevier, vol. 154(C), pages 934-943.
    16. Al-Sanea, Sami A. & Zedan, M.F. & Al-Ajlan, Saleh A., 2005. "Effect of electricity tariff on the optimum insulation-thickness in building walls as determined by a dynamic heat-transfer model," Applied Energy, Elsevier, vol. 82(4), pages 313-330, December.
    17. Al-Sanea, Sami A. & Zedan, M.F., 2011. "Improving thermal performance of building walls by optimizing insulation layer distribution and thickness for same thermal mass," Applied Energy, Elsevier, vol. 88(9), pages 3113-3124.
    Full references (including those not matched with items on IDEAS)

    Most related items

    These are the items that most often cite the same works as this one and are cited by the same works as this one.
    1. Abdul Mujeebu, Muhammad & Alshamrani, Othman Subhi, 2016. "Prospects of energy conservation and management in buildings – The Saudi Arabian scenario versus global trends," Renewable and Sustainable Energy Reviews, Elsevier, vol. 58(C), pages 1647-1663.
    2. Mazzeo, D. & Oliveti, G. & Arcuri, N., 2016. "Influence of internal and external boundary conditions on the decrement factor and time lag heat flux of building walls in steady periodic regime," Applied Energy, Elsevier, vol. 164(C), pages 509-531.
    3. Leccese, Francesco & Salvadori, Giacomo & Asdrubali, Francesco & Gori, Paola, 2018. "Passive thermal behaviour of buildings: Performance of external multi-layered walls and influence of internal walls," Applied Energy, Elsevier, vol. 225(C), pages 1078-1089.
    4. Berger, Julien & Mendes, Nathan, 2017. "An innovative method for the design of high energy performance building envelopes," Applied Energy, Elsevier, vol. 190(C), pages 266-277.
    5. Corrado, Vincenzo & Paduos, Simona, 2016. "New equivalent parameters for thermal characterization of opaque building envelope components under dynamic conditions," Applied Energy, Elsevier, vol. 163(C), pages 313-322.
    6. Kontoleon, Karolos J. & Saboor, Shaik & Mazzeo, Domenico & Ahmad, Jawad & Cuce, Erdem, 2023. "Thermal sensitivity and potential cooling-related energy saving of masonry walls through the lens of solar heat-rejecting paints at varying orientations," Applied Energy, Elsevier, vol. 329(C).
    7. Radhi, H., 2010. "On the optimal selection of wall cladding system to reduce direct and indirect CO2 emissions," Energy, Elsevier, vol. 35(3), pages 1412-1424.
    8. Al-Sanea, Sami A. & Zedan, M.F., 2011. "Improving thermal performance of building walls by optimizing insulation layer distribution and thickness for same thermal mass," Applied Energy, Elsevier, vol. 88(9), pages 3113-3124.
    9. Yang, Jianming & Lin, Zhongqi & Wu, Huijun & Chen, Qingchun & Xu, Xinhua & Huang, Gongsheng & Fan, Liseng & Shen, Xujun & Gan, Keming, 2020. "Inverse optimization of building thermal resistance and capacitance for minimizing air conditioning loads," Renewable Energy, Elsevier, vol. 148(C), pages 975-986.
    10. Cui, Hongzhi & Tang, Waiching & Qin, Qinghua & Xing, Feng & Liao, Wenyu & Wen, Haibo, 2017. "Development of structural-functional integrated energy storage concrete with innovative macro-encapsulated PCM by hollow steel ball," Applied Energy, Elsevier, vol. 185(P1), pages 107-118.
    11. Daouas, Naouel, 2011. "A study on optimum insulation thickness in walls and energy savings in Tunisian buildings based on analytical calculation of cooling and heating transmission loads," Applied Energy, Elsevier, vol. 88(1), pages 156-164, January.
    12. Mohan, Gowtham & Kumar, Uday & Pokhrel, Manoj Kumar & Martin, Andrew, 2016. "A novel solar thermal polygeneration system for sustainable production of cooling, clean water and domestic hot water in United Arab Emirates: Dynamic simulation and economic evaluation," Applied Energy, Elsevier, vol. 167(C), pages 173-188.
    13. Zhang, L.Y. & Jin, L.W. & Wang, Z.N. & Zhang, J.Y. & Liu, X. & Zhang, L.H., 2017. "Effects of wall configuration on building energy performance subject to different climatic zones of China," Applied Energy, Elsevier, vol. 185(P2), pages 1565-1573.
    14. Kontoleon, K.J. & Theodosiou, Th.G. & Tsikaloudaki, K.G., 2013. "The influence of concrete density and conductivity on walls’ thermal inertia parameters under a variety of masonry and insulation placements," Applied Energy, Elsevier, vol. 112(C), pages 325-337.
    15. Ahn, Jonghoon & Cho, Soolyeon & Chung, Dae Hun, 2017. "Analysis of energy and control efficiencies of fuzzy logic and artificial neural network technologies in the heating energy supply system responding to the changes of user demands," Applied Energy, Elsevier, vol. 190(C), pages 222-231.
    16. Rodrigues, Eugénio & Gaspar, Adélio Rodrigues & Gomes, Álvaro, 2014. "Improving thermal performance of automatically generated floor plans using a geometric variable sequential optimization procedure," Applied Energy, Elsevier, vol. 132(C), pages 200-215.
    17. Akeiber, Hussein & Nejat, Payam & Majid, Muhd Zaimi Abd. & Wahid, Mazlan A. & Jomehzadeh, Fatemeh & Zeynali Famileh, Iman & Calautit, John Kaiser & Hughes, Ben Richard & Zaki, Sheikh Ahmad, 2016. "A review on phase change material (PCM) for sustainable passive cooling in building envelopes," Renewable and Sustainable Energy Reviews, Elsevier, vol. 60(C), pages 1470-1497.
    18. Krarti, Moncef & Dubey, Kankana & Howarth, Nicholas, 2017. "Evaluation of building energy efficiency investment options for the Kingdom of Saudi Arabia," Energy, Elsevier, vol. 134(C), pages 595-610.
    19. Abdul Mujeebu, Muhammad & Ashraf, Noman & Alsuwayigh, Abdulkarim H., 2016. "Effect of nano vacuum insulation panel and nanogel glazing on the energy performance of office building," Applied Energy, Elsevier, vol. 173(C), pages 141-151.
    20. Nematchoua, Modeste Kameni & Raminosoa, Chrysostôme R.R. & Mamiharijaona, Ramaroson & René, Tchinda & Orosa, José A. & Elvis, Watis & Meukam, Pierre, 2015. "Study of the economical and optimum thermal insulation thickness for buildings in a wet and hot tropical climate: Case of Cameroon," Renewable and Sustainable Energy Reviews, Elsevier, vol. 50(C), pages 1192-1202.

    Corrections

    All material on this site has been provided by the respective publishers and authors. You can help correct errors and omissions. When requesting a correction, please mention this item's handle: RePEc:eee:appene:v:185:y:2017:i:p2:p:1585-1594. See general information about how to correct material in RePEc.

    If you have authored this item and are not yet registered with RePEc, we encourage you to do it here. This allows to link your profile to this item. It also allows you to accept potential citations to this item that we are uncertain about.

    If CitEc recognized a bibliographic reference but did not link an item in RePEc to it, you can help with this form .

    If you know of missing items citing this one, you can help us creating those links by adding the relevant references in the same way as above, for each refering item. If you are a registered author of this item, you may also want to check the "citations" tab in your RePEc Author Service profile, as there may be some citations waiting for confirmation.

    For technical questions regarding this item, or to correct its authors, title, abstract, bibliographic or download information, contact: Catherine Liu (email available below). General contact details of provider: http://www.elsevier.com/wps/find/journaldescription.cws_home/405891/description#description .

    Please note that corrections may take a couple of weeks to filter through the various RePEc services.

    IDEAS is a RePEc service. RePEc uses bibliographic data supplied by the respective publishers.