Author
Listed:
- Tae Hyun Kim
(Seoul National University
Seoul National University)
- Junwon Kang
(Seoul National University
Seoul National University)
- Haewook Jang
(Seoul National University)
- Hyelyn Joo
(Seoul National University)
- Gi Yoon Lee
(Seoul National University)
- Hamin Kim
(Seoul National University)
- Untack Cho
(QuantaMatrix Inc.)
- Hyeeun Bang
(QuantaMatrix Inc.)
- Jisung Jang
(QuantaMatrix Inc.)
- Sangkwon Han
(QuantaMatrix Inc.)
- Dong Young Kim
(QuantaMatrix Inc.)
- Chan Mi Lee
(Seoul National University College of Medicine)
- Chang Kyung Kang
(Seoul National University College of Medicine)
- Pyoeng Gyun Choe
(Seoul National University College of Medicine)
- Nam Joong Kim
(Seoul National University College of Medicine)
- Myoung-don Oh
(Seoul National University College of Medicine)
- Taek Soo Kim
(Seoul National University College of Medicine)
- Inho Kim
(Seoul National University College of Medicine)
- Wan Beom Park
(Seoul National University College of Medicine)
- Sunghoon Kwon
(Seoul National University
Seoul National University
Seoul National University
QuantaMatrix Inc.)
Abstract
Treatment assessment and patient outcome for sepsis depend predominantly on the timely administration of appropriate antibiotics1–3. However, the clinical protocols used to stratify and select patient-specific optimal therapy are extremely slow4. In particular, the major hurdle in performing rapid antimicrobial susceptibility testing (AST) remains in the lengthy blood culture procedure, which has long been considered unavoidable due to the limited number of pathogens present in the patient’s blood. Here we describe an ultra-rapid AST method that bypasses the need for traditional blood culture, thereby demonstrating potential to reduce the turnaround time of reporting drug susceptibility profiles by more than 40–60 h compared with hospital AST workflows. Introducing a synthetic beta-2-glycoprotein I peptide, a broad range of microbial pathogens are selectively recovered from whole blood, subjected to species identification or instantly proliferated and phenotypically evaluated for various drug conditions using a low-inoculum AST chip. The platform was clinically evaluated by the enrolment of 190 hospitalized patients suspected of having infection, achieving 100% match in species identification. Among the eight positive cases, six clinical isolates were retrospectively tested for AST showing an overall categorical agreement of 94.90% with an average theoretical turnaround time of 13 ± 2.53 h starting from initial blood processing.
Suggested Citation
Tae Hyun Kim & Junwon Kang & Haewook Jang & Hyelyn Joo & Gi Yoon Lee & Hamin Kim & Untack Cho & Hyeeun Bang & Jisung Jang & Sangkwon Han & Dong Young Kim & Chan Mi Lee & Chang Kyung Kang & Pyoeng Gyun, 2024.
"Blood culture-free ultra-rapid antimicrobial susceptibility testing,"
Nature, Nature, vol. 632(8026), pages 893-902, August.
Handle:
RePEc:nat:nature:v:632:y:2024:i:8026:d:10.1038_s41586-024-07725-1
DOI: 10.1038/s41586-024-07725-1
Download full text from publisher
As the access to this document is restricted, you may want to search for a different version of it.
Corrections
All material on this site has been provided by the respective publishers and authors. You can help correct errors and omissions. When requesting a correction, please mention this item's handle: RePEc:nat:nature:v:632:y:2024:i:8026:d:10.1038_s41586-024-07725-1. See general information about how to correct material in RePEc.
If you have authored this item and are not yet registered with RePEc, we encourage you to do it here. This allows to link your profile to this item. It also allows you to accept potential citations to this item that we are uncertain about.
We have no bibliographic references for this item. You can help adding them by using this form .
If you know of missing items citing this one, you can help us creating those links by adding the relevant references in the same way as above, for each refering item. If you are a registered author of this item, you may also want to check the "citations" tab in your RePEc Author Service profile, as there may be some citations waiting for confirmation.
For technical questions regarding this item, or to correct its authors, title, abstract, bibliographic or download information, contact: Sonal Shukla or Springer Nature Abstracting and Indexing (email available below). General contact details of provider: http://www.nature.com .
Please note that corrections may take a couple of weeks to filter through
the various RePEc services.