IDEAS home Printed from https://ideas.repec.org/a/gam/jsusta/v12y2020i18p7826-d417358.html
   My bibliography  Save this article

Utilisation of Mass and Night Ventilation in Decreasing Cooling Load Demand

Author

Listed:
  • Michael Darmanis

    (Faculty of Mechanical Engineering, Istanbul Technical University, Beyoğlu, Istanbul 34437, Turkey
    Laboratory of Fluid Mechanics, Department of Mechanical Engineering, University of West Attica, GR12244 Athens, Greece)

  • Murat Çakan

    (Faculty of Mechanical Engineering, Istanbul Technical University, Beyoğlu, Istanbul 34437, Turkey)

  • Konstantinos P. Moustris

    (Laboratory of Fluid Mechanics, Department of Mechanical Engineering, University of West Attica, GR12244 Athens, Greece)

  • Kosmas A. Kavadias

    (Laboratory of Soft Energy Applications & Environmental Protection, Department of Mechanical Engineering, University of West Attica, GR12244 Athens, Greece)

  • Konstantinos-Stefanos P. Nikas

    (Laboratory of Fluid Mechanics, Department of Mechanical Engineering, University of West Attica, GR12244 Athens, Greece
    Laboratory of Heat Transfer, Department of Mechanical Engineering, University of West Attica, GR12244 Athens, Greece)

Abstract

The building sector consumes 36% of the world’s energy and produces around 40% of energy-related carbon emissions. While the building industry moves towards a zero net greenhouse-gas emission policy, ventilation is, and will be, a necessity for the preservation of air quality—especially in climates defined by unsavoury conditions. Therefore, a “mixing mode” cooling system was employed to lower the required energy consumption at an earthen building situated in the premises of Istanbul Technical University. A room of the high-mass earthen building was monitored under different ventilation and shading conditions. Night ventilation was conducted using two modes, 3.2 and 2.3 air changes per hour, and the air conditioning unit, operating from 08:00 to 17:00, had a set temperature of 23 ∘ C . Night ventilation was somewhat impactful, reducing the average expected cooling energy demand up to 27%. Furthermore, the earthen building proved to be extremely effective on moderating extremes of temperature under non-ventilated conditions. During a rather hot day, with an outdoor maximum temperature of 35 ∘ C , the indoor maximum temperature of the high-mass building was only 25 ∘ C , namely within thermal comfort levels. The diurnal temperature proved to be key in the effective application of night ventilation.

Suggested Citation

  • Michael Darmanis & Murat Çakan & Konstantinos P. Moustris & Kosmas A. Kavadias & Konstantinos-Stefanos P. Nikas, 2020. "Utilisation of Mass and Night Ventilation in Decreasing Cooling Load Demand," Sustainability, MDPI, vol. 12(18), pages 1-11, September.
  • Handle: RePEc:gam:jsusta:v:12:y:2020:i:18:p:7826-:d:417358
    as

    Download full text from publisher

    File URL: https://www.mdpi.com/2071-1050/12/18/7826/pdf
    Download Restriction: no

    File URL: https://www.mdpi.com/2071-1050/12/18/7826/
    Download Restriction: no
    ---><---

    Citations

    Citations are extracted by the CitEc Project, subscribe to its RSS feed for this item.
    as


    Cited by:

    1. Mamdooh Alwetaishi & Ashraf Balabel & Ahmed Abdelhafiz & Usama Issa & Ibrahim Sharaky & Amal Shamseldin & Mohammed Al-Surf & Mosleh Al-Harthi & Mohamed Gadi, 2020. "User Thermal Comfort in Historic Buildings: Evaluation of the Potential of Thermal Mass, Orientation, Evaporative Cooling and Ventilation," Sustainability, MDPI, vol. 12(22), pages 1-23, November.
    2. Robert C. Vella & Charles Yousif & Francisco Javier Rey Martinez & Javier María Rey Hernandez, 2022. "Prioritising Passive Measures over Air Conditioning to Achieve Thermal Comfort in Mediterranean Baroque Churches," Sustainability, MDPI, vol. 14(14), pages 1-23, July.

    Corrections

    All material on this site has been provided by the respective publishers and authors. You can help correct errors and omissions. When requesting a correction, please mention this item's handle: RePEc:gam:jsusta:v:12:y:2020:i:18:p:7826-:d:417358. See general information about how to correct material in RePEc.

    If you have authored this item and are not yet registered with RePEc, we encourage you to do it here. This allows to link your profile to this item. It also allows you to accept potential citations to this item that we are uncertain about.

    We have no bibliographic references for this item. You can help adding them by using this form .

    If you know of missing items citing this one, you can help us creating those links by adding the relevant references in the same way as above, for each refering item. If you are a registered author of this item, you may also want to check the "citations" tab in your RePEc Author Service profile, as there may be some citations waiting for confirmation.

    For technical questions regarding this item, or to correct its authors, title, abstract, bibliographic or download information, contact: MDPI Indexing Manager (email available below). General contact details of provider: https://www.mdpi.com .

    Please note that corrections may take a couple of weeks to filter through the various RePEc services.

    IDEAS is a RePEc service. RePEc uses bibliographic data supplied by the respective publishers.