IDEAS home Printed from https://ideas.repec.org/a/gam/jijerp/v17y2020i23p8988-d455249.html
   My bibliography  Save this article

Influence of Connection Type and Platform Diameter on Titanium Dental Implants Fatigue: Non-Axial Loading Cyclic Test Analysis

Author

Listed:
  • Ana I. Nicolas-Silvente

    (Periodontal and Implant Surgery, CEIR Campus Mare Nostrum, School of Dentistry, University of Murcia, 30008 Murcia, Spain)

  • Eugenio Velasco-Ortega

    (Comprehensive Dentistry for Adults and Gerodontology, Faculty of Dentistry, University of Seville, 41009 Seville, Spain)

  • Ivan Ortiz-Garcia

    (Comprehensive Dentistry for Adults and Gerodontology, Faculty of Dentistry, University of Seville, 41009 Seville, Spain)

  • Alvaro Jimenez-Guerra

    (Comprehensive Dentistry for Adults and Gerodontology, Faculty of Dentistry, University of Seville, 41009 Seville, Spain)

  • Loreto Monsalve-Guil

    (Comprehensive Dentistry for Adults and Gerodontology, Faculty of Dentistry, University of Seville, 41009 Seville, Spain)

  • Raul Ayuso-Montero

    (Faculty of Dentistry, University of Barcelona, 08007 Barcelona, Spain)

  • Javier Gil

    (Chairman of Bioengineering Institute of Technology, Universitat Internacional de Catalunya, 08017 Barcelona, Spain)

  • Jose Lopez-Lopez

    (Faculty of Dentistry, Service of the Medical-Surgical Area of Dentistry Hospital, University of Barcelona, 08007 Barcelona, Spain)

Abstract

Two-pieces dental implants must provide stability of the implant-abutment-interface. The connection type and platform diameter could influence the biomechanical resistance and stress distribution. This study aims to evaluate the fatigue for different types of connections, external and internal, and different platform diameters. Three implant designs with the same length were used: (a) external hexagon/narrow platform; (b) internal double hexagon/narrow platform; (c) internal octagon/regular platform. A fatigue test was developed to establish the number of cycles needed before fracture. A 30º oblique load with a sinusoidal function of fatigue at a frequency of 15 Hz and 10% stress variation was applied to each system. The fatigue load limit (FLL) for design (a) was 190 N, being the nominal-curvature-moment (NCM) = 1.045; FLL = 150 N, with a NCM = 0.825 for (b), and FLL = 325 N, with a NCM = 1.788 for (c). The platform diameter affects the FLL, obtaining lower FLL on a narrow platform. The connection type interferes with the implant walls’ width, especially in narrow implants, making internal connections more unstable at this level. Long-term clinical studies to assess the restoration’s success rate and survival are mandatory.

Suggested Citation

  • Ana I. Nicolas-Silvente & Eugenio Velasco-Ortega & Ivan Ortiz-Garcia & Alvaro Jimenez-Guerra & Loreto Monsalve-Guil & Raul Ayuso-Montero & Javier Gil & Jose Lopez-Lopez, 2020. "Influence of Connection Type and Platform Diameter on Titanium Dental Implants Fatigue: Non-Axial Loading Cyclic Test Analysis," IJERPH, MDPI, vol. 17(23), pages 1-12, December.
  • Handle: RePEc:gam:jijerp:v:17:y:2020:i:23:p:8988-:d:455249
    as

    Download full text from publisher

    File URL: https://www.mdpi.com/1660-4601/17/23/8988/pdf
    Download Restriction: no

    File URL: https://www.mdpi.com/1660-4601/17/23/8988/
    Download Restriction: no
    ---><---

    References listed on IDEAS

    as
    1. Hélder Oliveira & Aritza Brizuela Velasco & José-Vicente Ríos-Santos & Fernando Sánchez Lasheras & Bernardo Ferreira Lemos & Francisco Javier Gil & Alexandrine Carvalho & Mariano Herrero-Climent, 2020. "Effect of Different Implant Designs on Strain and Stress Distribution under Non-Axial Loading: A Three-Dimensional Finite Element Analysis," IJERPH, MDPI, vol. 17(13), pages 1-17, July.
    Full references (including those not matched with items on IDEAS)

    Most related items

    These are the items that most often cite the same works as this one and are cited by the same works as this one.
    1. Seokho Ahn & Jaesung Kim & Seok Chan Jeong & Myungil Kim & Cheolyoung Kim & Dongki Park, 2022. "Stress Distribution Analysis of Threaded Implants for Digital Dentistry," IJERPH, MDPI, vol. 19(19), pages 1-14, October.
    2. José Vicente Ríos-Santos & Gregorio Tello-González & Pedro Lázaro-Calvo & Francisco Javier Gil Mur & Blanca Ríos-Carrasco & Ana Fernández-Palacín & Mariano Herrero-Climent, 2020. "One Abutment One Time: A Multicenter, Prospective, Controlled, Randomized Study," IJERPH, MDPI, vol. 17(24), pages 1-17, December.

    Corrections

    All material on this site has been provided by the respective publishers and authors. You can help correct errors and omissions. When requesting a correction, please mention this item's handle: RePEc:gam:jijerp:v:17:y:2020:i:23:p:8988-:d:455249. See general information about how to correct material in RePEc.

    If you have authored this item and are not yet registered with RePEc, we encourage you to do it here. This allows to link your profile to this item. It also allows you to accept potential citations to this item that we are uncertain about.

    If CitEc recognized a bibliographic reference but did not link an item in RePEc to it, you can help with this form .

    If you know of missing items citing this one, you can help us creating those links by adding the relevant references in the same way as above, for each refering item. If you are a registered author of this item, you may also want to check the "citations" tab in your RePEc Author Service profile, as there may be some citations waiting for confirmation.

    For technical questions regarding this item, or to correct its authors, title, abstract, bibliographic or download information, contact: MDPI Indexing Manager (email available below). General contact details of provider: https://www.mdpi.com .

    Please note that corrections may take a couple of weeks to filter through the various RePEc services.

    IDEAS is a RePEc service. RePEc uses bibliographic data supplied by the respective publishers.