IDEAS home Printed from https://ideas.repec.org/a/gam/jijerp/v17y2020i19p7316-d424583.html
   My bibliography  Save this article

Indoor Air Design Parameters of Air Conditioners for Mold-Prevention and Antibacterial in Island Residential Buildings

Author

Listed:
  • Xueyan Zhang

    (School of Civil Engineering, Dalian University of Technology, Dalian 116024, China)

  • Jingyi Liang

    (School of Civil Engineering, Dalian University of Technology, Dalian 116024, China)

  • Beibei Wang

    (School of Civil Engineering, Dalian University of Technology, Dalian 116024, China)

  • Yang Lv

    (School of Civil Engineering, Dalian University of Technology, Dalian 116024, China)

  • Jingchao Xie

    (School of Construction Engineering, Beijing University of Technology, Beijing 100000, China)

Abstract

The climate characteristics of the islands in the Nansha Islands of China are a typical marine climate including high temperature, high relative humidity, high salt content, strong solar radiation, and long sunshine. These can provide suitable conditions for mold reproduction on the surface of the wall in a building. Therefore, mildew pollution on the wall for a long time can easily damage the building’s structure. It does not only directly affect the appearance of the building, but also indirectly affects the indoor environment and human health. In this paper, dominant fungi in the residential buildings on thee Nansha Islands of China are Aspergillus , Penicillium, and Cladosporium . Critical lines of temperature and relative humidity for mould growth on the interior surfaces of island residential building envelopes have been given and discussed. The results show that the risk of mould growth on the wall with different materials, from low to high, is reinforced concrete, aerated concrete block, coral aggregate, brick, and wood. Furthermore, in order to prevent the room regulated by air conditioner from being contaminated by mould, indoor air temperature should be set variable and controlled between 26 °C and 28 °C, the relative humidity should be changed between 50% and 80%.

Suggested Citation

  • Xueyan Zhang & Jingyi Liang & Beibei Wang & Yang Lv & Jingchao Xie, 2020. "Indoor Air Design Parameters of Air Conditioners for Mold-Prevention and Antibacterial in Island Residential Buildings," IJERPH, MDPI, vol. 17(19), pages 1-16, October.
  • Handle: RePEc:gam:jijerp:v:17:y:2020:i:19:p:7316-:d:424583
    as

    Download full text from publisher

    File URL: https://www.mdpi.com/1660-4601/17/19/7316/pdf
    Download Restriction: no

    File URL: https://www.mdpi.com/1660-4601/17/19/7316/
    Download Restriction: no
    ---><---

    References listed on IDEAS

    as
    1. Brambilla, Arianna & Sangiorgio, Alberto, 2020. "Mould growth in energy efficient buildings: Causes, health implications and strategies to mitigate the risk," Renewable and Sustainable Energy Reviews, Elsevier, vol. 132(C).
    Full references (including those not matched with items on IDEAS)

    Most related items

    These are the items that most often cite the same works as this one and are cited by the same works as this one.
    1. Eleonora Laurini & Mariangela De Vita & Pierluigi De Berardinis, 2021. "Monitoring the Indoor Air Quality: A Case Study of Passive Cooling from Historical Hypogeal Rooms," Energies, MDPI, vol. 14(9), pages 1-15, April.
    2. Lisa Coulburn & Wendy Miller, 2022. "Prevalence, Risk Factors and Impacts Related to Mould-Affected Housing: An Australian Integrative Review," IJERPH, MDPI, vol. 19(3), pages 1-26, February.
    3. Hélène Niculita-Hirzel, 2022. "Latest Trends in Pollutant Accumulations at Threatening Levels in Energy-Efficient Residential Buildings with and without Mechanical Ventilation: A Review," IJERPH, MDPI, vol. 19(6), pages 1-12, March.
    4. Alexander Rieser & Rainer Pfluger & Alexandra Troi & Daniel Herrera-Avellanosa & Kirsten Engelund Thomsen & Jørgen Rose & Zeynep Durmuş Arsan & Gulden Gokcen Akkurt & Gerhard Kopeinig & Gaëlle Guyot &, 2021. "Integration of Energy-Efficient Ventilation Systems in Historic Buildings—Review and Proposal of a Systematic Intervention Approach," Sustainability, MDPI, vol. 13(4), pages 1-21, February.

    Corrections

    All material on this site has been provided by the respective publishers and authors. You can help correct errors and omissions. When requesting a correction, please mention this item's handle: RePEc:gam:jijerp:v:17:y:2020:i:19:p:7316-:d:424583. See general information about how to correct material in RePEc.

    If you have authored this item and are not yet registered with RePEc, we encourage you to do it here. This allows to link your profile to this item. It also allows you to accept potential citations to this item that we are uncertain about.

    If CitEc recognized a bibliographic reference but did not link an item in RePEc to it, you can help with this form .

    If you know of missing items citing this one, you can help us creating those links by adding the relevant references in the same way as above, for each refering item. If you are a registered author of this item, you may also want to check the "citations" tab in your RePEc Author Service profile, as there may be some citations waiting for confirmation.

    For technical questions regarding this item, or to correct its authors, title, abstract, bibliographic or download information, contact: MDPI Indexing Manager (email available below). General contact details of provider: https://www.mdpi.com .

    Please note that corrections may take a couple of weeks to filter through the various RePEc services.

    IDEAS is a RePEc service. RePEc uses bibliographic data supplied by the respective publishers.