IDEAS home Printed from https://ideas.repec.org/a/gam/jijerp/v17y2020i18p6733-d414146.html
   My bibliography  Save this article

Reliability of the Resonance Frequency Analysis Values in New Prototype Transepithelial Abutments: A Prospective Clinical Study

Author

Listed:
  • María Guerrero-González

    (Periodontics, Faculty of Health and Sport Sciences, Universidad de Zaragoza, C/Velódromo S/N, 22006 Huesca, Spain)

  • Francesca Monticelli

    (Periodontics, Faculty of Health and Sport Sciences, Universidad de Zaragoza, C/Velódromo S/N, 22006 Huesca, Spain)

  • David Saura García-Martín

    (Periodontics, Faculty of Health and Sport Sciences, Universidad de Zaragoza, C/Velódromo S/N, 22006 Huesca, Spain)

  • Mariano Herrero-Climent

    (Porto Dental Institute, 4150-518 Porto, Portugal)

  • Blanca Ríos-Carrasco

    (Advanced Periodontics, School of Dentistry, Universidad de Sevilla, C/Avicena S/N, 41009 Sevilla, Spain)

  • José-Vicente Ríos-Santos

    (Advanced Periodontics, School of Dentistry, Universidad de Sevilla, C/Avicena S/N, 41009 Sevilla, Spain)

  • Ana Fernández-Palacín

    (Department of Social and Health Sciences, Universidad de Sevilla, 41009 Sevilla, Spain)

Abstract

Resonance frequency analysis (RFA) requires abutment disconnection to monitor implant stability. To overcome this limitation, an experimental transepithelial abutment was designed to allow a SmartPeg to be screwed onto it, in order to determine the prototype abutments repeatability and reproducibility using Osstell ISQ and to assess whether implant length and diameter have an influence on the reliability of these measurements. RFA was conducted with a SmartPeg screwed directly into the implant and onto experimental abutments of different heights of 2, 3.5 and 5 mm. A total of 32 patients (116 implants) were tested. RFA measurements were taken twice for each group from mesial, distal, buccal and palatal/lingual surfaces. Mean values and SD were calculated and Intraclass Correlation Coefficients (ICC) ( p < 0.05, IC 95%). The implant stability quotient (ISQ) mean values were 72.581 measured directly to implant and 72.899 (2 mm), 72.391 (3.5 mm) and 71.458 (5 mm) measured from the prototypes. ICC between measurements made directly to implant and through 2-, 3.5- and 5-mm abutments were 0.908, 0.919 and 0.939, respectively. RFA values registered through the experimental transepithelial abutments achieved a high reliability. Neither the implant length nor the diameter had any influence on the measurements’ reliability.

Suggested Citation

  • María Guerrero-González & Francesca Monticelli & David Saura García-Martín & Mariano Herrero-Climent & Blanca Ríos-Carrasco & José-Vicente Ríos-Santos & Ana Fernández-Palacín, 2020. "Reliability of the Resonance Frequency Analysis Values in New Prototype Transepithelial Abutments: A Prospective Clinical Study," IJERPH, MDPI, vol. 17(18), pages 1-13, September.
  • Handle: RePEc:gam:jijerp:v:17:y:2020:i:18:p:6733-:d:414146
    as

    Download full text from publisher

    File URL: https://www.mdpi.com/1660-4601/17/18/6733/pdf
    Download Restriction: no

    File URL: https://www.mdpi.com/1660-4601/17/18/6733/
    Download Restriction: no
    ---><---

    References listed on IDEAS

    as
    1. Adrián Maximiano Millán & Rocío Bravo Álvarez & Miguel Plana Montori & María Guerrero González & David Saura García-Martín & Blanca Ríos-Carrasco & Francesca Monticelli & José Vicente Ríos-Santos & An, 2020. "Assessment of the Simultaneous Use of Biomaterials in Transalveolar Sinus Floor Elevation: Prospective Randomized Clinical Trial in Humans," IJERPH, MDPI, vol. 17(6), pages 1-11, March.
    Full references (including those not matched with items on IDEAS)

    Most related items

    These are the items that most often cite the same works as this one and are cited by the same works as this one.
    1. Eugenio Velasco-Ortega & Angela Sierra-Baztan & Alvaro Jiménez-Guerra & Antonio España-López & Iván Ortiz-Garcia & Enrique Núñez-Márquez & Jesús Moreno-Muñoz & José Luis Rondón-Romero & José López-Lóp, 2021. "Long-Term Clinical Study of Implants Placed in Maxillary Sinus Floor Augmentation Using Beta-Tricalcium Phosphate," IJERPH, MDPI, vol. 18(19), pages 1-14, September.
    2. Rodrigo Andrés-García & José Vicente Ríos-Santos & Mariano Herrero-Climent & Pedro Bullón & Javier Fernández-Farhall & Alberto Gómez-Menchero & Ana Fernández-Palacín & Blanca Ríos-Carrasco, 2021. "Sinus Floor Elevation via an Osteotome Technique without Biomaterials," IJERPH, MDPI, vol. 18(3), pages 1-13, January.

    Corrections

    All material on this site has been provided by the respective publishers and authors. You can help correct errors and omissions. When requesting a correction, please mention this item's handle: RePEc:gam:jijerp:v:17:y:2020:i:18:p:6733-:d:414146. See general information about how to correct material in RePEc.

    If you have authored this item and are not yet registered with RePEc, we encourage you to do it here. This allows to link your profile to this item. It also allows you to accept potential citations to this item that we are uncertain about.

    If CitEc recognized a bibliographic reference but did not link an item in RePEc to it, you can help with this form .

    If you know of missing items citing this one, you can help us creating those links by adding the relevant references in the same way as above, for each refering item. If you are a registered author of this item, you may also want to check the "citations" tab in your RePEc Author Service profile, as there may be some citations waiting for confirmation.

    For technical questions regarding this item, or to correct its authors, title, abstract, bibliographic or download information, contact: MDPI Indexing Manager (email available below). General contact details of provider: https://www.mdpi.com .

    Please note that corrections may take a couple of weeks to filter through the various RePEc services.

    IDEAS is a RePEc service. RePEc uses bibliographic data supplied by the respective publishers.