Author
Listed:
- Sergio Arrieta Meza
(Diram, Calle Libertad 325 Ote, Casco Urbano, San Pedro Garza García 66200, N.L., Mexico)
- Fernando Salinas Salinas
(Universidad Autónoma de Nuevo León (UANL), Facultad de Ingeniería Mecánica y Eléctrica (FIME), Avenida Universidad S/N Ciudad Universitaria, San Nicolás de los Garza 66455, N.L., Mexico)
- Luis Alonso Trujillo Guajardo
(Universidad Autónoma de Nuevo León (UANL), Facultad de Ingeniería Mecánica y Eléctrica (FIME), Avenida Universidad S/N Ciudad Universitaria, San Nicolás de los Garza 66455, N.L., Mexico)
- Luis Humberto Rodríguez Alfaro
(Universidad Autónoma de Nuevo León (UANL), Facultad de Ingeniería Mecánica y Eléctrica (FIME), Avenida Universidad S/N Ciudad Universitaria, San Nicolás de los Garza 66455, N.L., Mexico)
- Mario Alberto González Vázquez
(Universidad Autónoma de Nuevo León (UANL), Facultad de Ingeniería Mecánica y Eléctrica (FIME), Avenida Universidad S/N Ciudad Universitaria, San Nicolás de los Garza 66455, N.L., Mexico)
- Johnny Rodríguez Maldonado
(Universidad Autónoma de Nuevo León (UANL), Facultad de Ingeniería Mecánica y Eléctrica (FIME), Avenida Universidad S/N Ciudad Universitaria, San Nicolás de los Garza 66455, N.L., Mexico)
- Miguel Angel Platas-Garza
(Universidad Autónoma de Nuevo León (UANL), Facultad de Ingeniería Mecánica y Eléctrica (FIME), Avenida Universidad S/N Ciudad Universitaria, San Nicolás de los Garza 66455, N.L., Mexico)
Abstract
This paper presents a methodology to calculate the neutral unbalanced current in C-type filters with an ungrounded double Wye topology; this equipment is widely used in the steel sector to mitigate the harmonic content in electrical installations caused by electric furnaces used in metal smelting processes. A common failure in these filters is the current unbalance caused by the degradation of the capacitor and inductor modules, leading to dangerous surges that affect these components, possible harmonic resonances, and deficient filtering by the equipment. Currently, there are no documented strategies for calculating the neutral current that allow for the proper adjustment of neutral protection in this type of equipment, resulting in catastrophic failures, costly unscheduled shutdowns, and potential harm to plant personnel. In this paper, we propose a methodology for calculating the unbalanced current in double Wye C-type harmonic filters, considering the natural degradation of capacitor and inductor modules and based on on-site measurements of the impedances for each element of the equipment. This allows for the predictive maintenance of these devices and the precise adjustment of neutral overcurrent protection. First, we review the operating principle of C-type harmonic filters and the neutral protection scheme. Then, the calculation methodology is proposed and validated in two practical case studies. In the first case, a 45 Mvar C-type second harmonic filter connected to a 34.5 kV bus is analyzed. In the second case, an 18.5 Mvar C-type second harmonic filter, part of a ±80 Mvar STATCOM system, connected to a 34.5 kV bus is examined. In both cases, these filters reduce the harmonic content in two steel plants: the first connected to a 400 kV bus and the second to a 230 kV bus. The results obtained with the proposed methodology were implemented in the protection device for a neutral current imbalance, considering different degradation values of the capacitors, and compared with the manufacturer’s suggested settings. The discussion highlights the good performance of the proposed methodology, particularly in terms of the protection device’s response speed to a risky unbalanced current.
Suggested Citation
Sergio Arrieta Meza & Fernando Salinas Salinas & Luis Alonso Trujillo Guajardo & Luis Humberto Rodríguez Alfaro & Mario Alberto González Vázquez & Johnny Rodríguez Maldonado & Miguel Angel Platas-Garz, 2024.
"Method for Calculating the Unbalanced Current in Ungrounded Double Wye C-Type Harmonic Filters,"
Energies, MDPI, vol. 17(22), pages 1-16, November.
Handle:
RePEc:gam:jeners:v:17:y:2024:i:22:p:5547-:d:1515318
Download full text from publisher
Most related items
These are the items that most often cite the same works as this one and are cited by the same works as this one.
- Jacek Kozyra & Andriy Lozynskyy & Zbigniew Łukasik & Aldona Kuśmińska-Fijałkowska & Andriy Kutsyk & Grzegorz Podskarbi & Yaroslav Paranchuk & Lidiia Kasha, 2022.
"Combined Control System for the Coordinates of the Electric Mode in the Electrotechnological Complex “Arc Steel Furnace-Power-Supply Network”,"
Energies, MDPI, vol. 15(14), pages 1-21, July.
- Zbigniew Olczykowski, 2022.
"Arc Furnace Power-Susceptibility Coefficients,"
Energies, MDPI, vol. 15(15), pages 1-21, July.
- Pegah Hamedani & Cristian Garcia & Jose Rodriguez, 2023.
"A Comprehensive Evaluation of Different Power Quantities in DC Electric Arc Furnace Power Supplies,"
Energies, MDPI, vol. 16(9), pages 1-24, May.
- Yaroslav Paranchuk & Daniel Jancarczyk & Pawel Falat, 2023.
"Study and Analysis of Dynamics and Energy Efficiency of Arc Steelmaking Furnace Electrical Mode with a Fuzzy Control Algorithm,"
Energies, MDPI, vol. 16(8), pages 1-19, April.
Corrections
All material on this site has been provided by the respective publishers and authors. You can help correct errors and omissions. When requesting a correction, please mention this item's handle: RePEc:gam:jeners:v:17:y:2024:i:22:p:5547-:d:1515318. See general information about how to correct material in RePEc.
If you have authored this item and are not yet registered with RePEc, we encourage you to do it here. This allows to link your profile to this item. It also allows you to accept potential citations to this item that we are uncertain about.
If CitEc recognized a bibliographic reference but did not link an item in RePEc to it, you can help with this form .
If you know of missing items citing this one, you can help us creating those links by adding the relevant references in the same way as above, for each refering item. If you are a registered author of this item, you may also want to check the "citations" tab in your RePEc Author Service profile, as there may be some citations waiting for confirmation.
For technical questions regarding this item, or to correct its authors, title, abstract, bibliographic or download information, contact: MDPI Indexing Manager (email available below). General contact details of provider: https://www.mdpi.com .
Please note that corrections may take a couple of weeks to filter through
the various RePEc services.