Abstract
Electrical resistance is among the characteristics that fastening systems must meet to ensure the proper functioning of signaling systems in railway infrastructure. The EN 13146-5:2012 standard specifies a laboratory testing method for determining the electrical resistance under wet conditions between running rails provided by a fastening system on steel or concrete sleepers. In urban railway tracks, the electrical resistance of fastening systems affects the stray current; however, there is no standardized electrical resistance measuring method. There is also no definition for the minimum value that the electrical resistance of fastening systems must satisfy to prevent stray currents. For this reason, this paper analysis the possibility of using the standard EN 13146-5:2012 for the measurement and analysis of the electrical resistance of fastening systems in urban railway tracks. In this study, the electrical resistance of different fastening systems used in urban railway tracks was measured. Based on the tests results, the modifications needed in the EN 13146-5 standard for it to be suitable for urban railway tracks were identified. The proposed modifications include the use of a DC current source. The test should be performed on a rail sample fastened to the concrete base, and the current circuit should be closed by the reference electrode installed in the base. Spraying water from nozzles is not applicable for this measurement. The test should be performed under dry conditions and at different water levels (water on the top of the concrete base and on the top of the levelling layer). Different water levels were used to simulate the most common conditions in urban railway tracks built as part of the road surface, where the track-drying process is very slow. The test should not be performed when the rails are immersed in water, because the current flows directly from the rail into the water in such case, and the fastening system has no influence on the measured electrical resistance value. In addition to describing the proposed changes, the calculation of the minimum electrical resistance value that fastening systems in urban railway tracks must satisfy is also presented.
Suggested Citation
Katarina Vranešić & Ivo Haladin & Stjepan Lakušić & Krešimir Burnać, 2023.
"Convenient Procedure for Measuring the Electrical Resistance of Fastening Systems in Urban Railway Tracks,"
Energies, MDPI, vol. 16(4), pages 1-16, February.
Handle:
RePEc:gam:jeners:v:16:y:2023:i:4:p:1990-:d:1071561
Download full text from publisher
Corrections
All material on this site has been provided by the respective publishers and authors. You can help correct errors and omissions. When requesting a correction, please mention this item's handle: RePEc:gam:jeners:v:16:y:2023:i:4:p:1990-:d:1071561. See general information about how to correct material in RePEc.
If you have authored this item and are not yet registered with RePEc, we encourage you to do it here. This allows to link your profile to this item. It also allows you to accept potential citations to this item that we are uncertain about.
We have no bibliographic references for this item. You can help adding them by using this form .
If you know of missing items citing this one, you can help us creating those links by adding the relevant references in the same way as above, for each refering item. If you are a registered author of this item, you may also want to check the "citations" tab in your RePEc Author Service profile, as there may be some citations waiting for confirmation.
For technical questions regarding this item, or to correct its authors, title, abstract, bibliographic or download information, contact: MDPI Indexing Manager (email available below). General contact details of provider: https://www.mdpi.com .
Please note that corrections may take a couple of weeks to filter through
the various RePEc services.