IDEAS home Printed from https://ideas.repec.org/a/gam/jeners/v16y2023i15p5738-d1208095.html
   My bibliography  Save this article

Analysis of Natural Pollution Accumulation Characteristics of Insulators for Railroads in High-Altitude Environment

Author

Listed:
  • Zhijin Zhang

    (Xuefeng Mountain Energy Equipment Safety National Observation and Research Station, Chongqing University, Chongqing 400044, China)

  • Siyi Chen

    (Xuefeng Mountain Energy Equipment Safety National Observation and Research Station, Chongqing University, Chongqing 400044, China)

  • Xingliang Jiang

    (Xuefeng Mountain Energy Equipment Safety National Observation and Research Station, Chongqing University, Chongqing 400044, China)

  • Jianlin Hu

    (Xuefeng Mountain Energy Equipment Safety National Observation and Research Station, Chongqing University, Chongqing 400044, China)

  • Qin Hu

    (Xuefeng Mountain Energy Equipment Safety National Observation and Research Station, Chongqing University, Chongqing 400044, China)

Abstract

Railway system insulators are affected by pollution, altitude, and other environmental situations during operation, which causes reduced electrical performance or even flashover accidents. These factors threaten the safety of railway operations in high-altitude areas. However, the natural contamination characteristics of a railroad in a plateau area is still unclear. In this study, a natural pollution accumulation test for railway insulators in a high-altitude area was carried out, and the distribution rules of nonsoluble deposit density ( NSDD ), equivalent salt deposit density ( ESDD ), NSDD/ESDD ratio, and nonuniformity ( T/B ) of the pollution distribution of the tested insulators were calculated. Meanwhile, the chemical compositions of the pollution from different test sites were analyzed. The differences of pollution accumulation between railway insulators and suspended insulators of a power system and the influencing factors were compared and analyzed by combining with a numerical simulation. The results show that the pollution level of railroad insulators is mainly distributed in level b and above. A pollution sample is mainly composed of sodium chloride, while the NSDD/ESDD ratio of pollution is mostly distributed from 0 to 5, with T/B value ranges from 1/0.62 to 1/1.76. The amount of insulator contamination is influenced by the location inside and outside the tunnel. Additionally, the pollution amount is influenced by the structure and type of insulators. Finally, this paper studies the creepage distance and structural height required by railway insulators in a plateau area according to the natural pollution accumulation characteristics of railway insulators, which can provide a reference for a railway electrical external insulation configuration in a high-altitude area.

Suggested Citation

  • Zhijin Zhang & Siyi Chen & Xingliang Jiang & Jianlin Hu & Qin Hu, 2023. "Analysis of Natural Pollution Accumulation Characteristics of Insulators for Railroads in High-Altitude Environment," Energies, MDPI, vol. 16(15), pages 1-14, August.
  • Handle: RePEc:gam:jeners:v:16:y:2023:i:15:p:5738-:d:1208095
    as

    Download full text from publisher

    File URL: https://www.mdpi.com/1996-1073/16/15/5738/pdf
    Download Restriction: no

    File URL: https://www.mdpi.com/1996-1073/16/15/5738/
    Download Restriction: no
    ---><---

    References listed on IDEAS

    as
    1. Shanpeng Zhao & Chenrui Zhang & Youpeng Zhang & Sihua Wang, 2019. "Influence of Partial Arc on Electric Field Distribution of Insulator Strings for Electrified Railway Catenary," Energies, MDPI, vol. 12(17), pages 1-16, August.
    Full references (including those not matched with items on IDEAS)

    Most related items

    These are the items that most often cite the same works as this one and are cited by the same works as this one.
    1. Yinping Li & Tianxu Jin & Li Liu & Kun Yuan, 2020. "Dynamic Performance Simulation and Stable Current Collection Analysis of a Pantograph Catenary System for Trolley Wire Overhead Electrically Actuated LHD," Energies, MDPI, vol. 13(5), pages 1-17, February.

    Corrections

    All material on this site has been provided by the respective publishers and authors. You can help correct errors and omissions. When requesting a correction, please mention this item's handle: RePEc:gam:jeners:v:16:y:2023:i:15:p:5738-:d:1208095. See general information about how to correct material in RePEc.

    If you have authored this item and are not yet registered with RePEc, we encourage you to do it here. This allows to link your profile to this item. It also allows you to accept potential citations to this item that we are uncertain about.

    If CitEc recognized a bibliographic reference but did not link an item in RePEc to it, you can help with this form .

    If you know of missing items citing this one, you can help us creating those links by adding the relevant references in the same way as above, for each refering item. If you are a registered author of this item, you may also want to check the "citations" tab in your RePEc Author Service profile, as there may be some citations waiting for confirmation.

    For technical questions regarding this item, or to correct its authors, title, abstract, bibliographic or download information, contact: MDPI Indexing Manager (email available below). General contact details of provider: https://www.mdpi.com .

    Please note that corrections may take a couple of weeks to filter through the various RePEc services.

    IDEAS is a RePEc service. RePEc uses bibliographic data supplied by the respective publishers.