IDEAS home Printed from https://ideas.repec.org/a/gam/jeners/v15y2022i9p3350-d808442.html
   My bibliography  Save this article

Possibilities of Adapting a Free-Cooling System in an Existing Commercial Building

Author

Listed:
  • Sławomir Rabczak

    (The Faculty of Civil and Environmental Engineering and Architecture, Rzeszow University of Technology, 35-959 Rzeszow, Poland)

  • Krzysztof Nowak

    (The Faculty of Civil and Environmental Engineering and Architecture, Rzeszow University of Technology, 35-959 Rzeszow, Poland)

Abstract

Increasingly, the exploitation of buildings involves the need for comprehensive management of all systems operating within it, their continuous monitoring, both for the safety of users and to mainly optimize the operating parameters of systems that are largely dependent on each other, interact with each other. This is mainly associated with the need for the most energy-efficient management of energy consumption, which has the largest share of operating costs. The main cost for the facilities is the cooling aspect, which is significant, and for this reason, it is necessary to analyze the possibility of its minimization. One of the possible systems to consider in order to reduce the consumption of cooling energy in the facility is the application of free-cooling technology, which is based on the use of the natural cooling capacity of the outside air for cooling rooms with high heat gains. The application of the free cooling system for facilities with a relatively stable cooling load, with significant heat gains from equipment is justified due to the possibility of maintaining low room temperatures, below the comfort value for people, for a long period of time. The problem arises when a large proportion of the heat gains are from people. In such a situation, cooling of rooms is possible but requires a large amount of ventilation air, which is already a serious limitation on the one hand because of the existing air conditioning equipment, lack of possibility to increase the ventilation air stream; on the other hand, the low heat capacity of the air itself, compared to, e.g., water systems used for cooling of the facility or multisplit systems. These limitations put a question mark over the possibility of adapting the technology of free cooling for the existing facilities, where the majority of heat gains come from people. It is not possible in such objects to lower the room temperature below the limit values for the sake of thermal comfort, which in itself limits the possibilities of using air as a natural cooling agent in such objects. Based on the measurement data obtained from the object, it was decided to check the possibilities of applying free-cooling technology in a large shopping facility and obtaining an answer as to what extent it is possible to reduce the power of cooling units with the application of free-cooling exchangers.

Suggested Citation

  • Sławomir Rabczak & Krzysztof Nowak, 2022. "Possibilities of Adapting a Free-Cooling System in an Existing Commercial Building," Energies, MDPI, vol. 15(9), pages 1-10, May.
  • Handle: RePEc:gam:jeners:v:15:y:2022:i:9:p:3350-:d:808442
    as

    Download full text from publisher

    File URL: https://www.mdpi.com/1996-1073/15/9/3350/pdf
    Download Restriction: no

    File URL: https://www.mdpi.com/1996-1073/15/9/3350/
    Download Restriction: no
    ---><---

    References listed on IDEAS

    as
    1. Muñoz, J. & Martínez-Val, J.M. & Abbas, R. & Abánades, A., 2012. "Dry cooling with night cool storage to enhance solar power plants performance in extreme conditions areas," Applied Energy, Elsevier, vol. 92(C), pages 429-436.
    Full references (including those not matched with items on IDEAS)

    Most related items

    These are the items that most often cite the same works as this one and are cited by the same works as this one.
    1. Boukelia, T.E. & Bouraoui, A. & Laouafi, A. & Djimli, S. & Kabar, Y., 2020. "3E (Energy-Exergy-Economic) comparative study of integrating wet and dry cooling systems in solar tower power plants," Energy, Elsevier, vol. 200(C).
    2. Dyreson, Ana & Miller, Franklin, 2016. "Night sky cooling for concentrating solar power plants," Applied Energy, Elsevier, vol. 180(C), pages 276-286.
    3. Sait, Hani H. & Martinez-Val, Jose M. & Abbas, Ruben & Munoz-Anton, Javier, 2015. "Fresnel-based modular solar fields for performance/cost optimization in solar thermal power plants: A comparison with parabolic trough collectors," Applied Energy, Elsevier, vol. 141(C), pages 175-189.
    4. Tarun Kumar Aseri & Chandan Sharma & Tara C. Kandpal, 2022. "Condenser cooling technologies for concentrating solar power plants: a review," Environment, Development and Sustainability: A Multidisciplinary Approach to the Theory and Practice of Sustainable Development, Springer, vol. 24(4), pages 4511-4565, April.
    5. Chiu, Justin N.W. & Gravoille, Pauline & Martin, Viktoria, 2013. "Active free cooling optimization with thermal energy storage in Stockholm," Applied Energy, Elsevier, vol. 109(C), pages 523-529.
    6. Wu, Yunna & Geng, Shuai & Zhang, Haobo & Gao, Min, 2014. "Decision framework of solar thermal power plant site selection based on linguistic Choquet operator," Applied Energy, Elsevier, vol. 136(C), pages 303-311.

    Corrections

    All material on this site has been provided by the respective publishers and authors. You can help correct errors and omissions. When requesting a correction, please mention this item's handle: RePEc:gam:jeners:v:15:y:2022:i:9:p:3350-:d:808442. See general information about how to correct material in RePEc.

    If you have authored this item and are not yet registered with RePEc, we encourage you to do it here. This allows to link your profile to this item. It also allows you to accept potential citations to this item that we are uncertain about.

    If CitEc recognized a bibliographic reference but did not link an item in RePEc to it, you can help with this form .

    If you know of missing items citing this one, you can help us creating those links by adding the relevant references in the same way as above, for each refering item. If you are a registered author of this item, you may also want to check the "citations" tab in your RePEc Author Service profile, as there may be some citations waiting for confirmation.

    For technical questions regarding this item, or to correct its authors, title, abstract, bibliographic or download information, contact: MDPI Indexing Manager (email available below). General contact details of provider: https://www.mdpi.com .

    Please note that corrections may take a couple of weeks to filter through the various RePEc services.

    IDEAS is a RePEc service. RePEc uses bibliographic data supplied by the respective publishers.