IDEAS home Printed from https://ideas.repec.org/a/gam/jeners/v15y2022i4p1297-d746626.html
   My bibliography  Save this article

Flashover Voltage Prediction Models under Agricultural and Biological Contaminant Conditions on Insulators

Author

Listed:
  • Shabana Khatoon

    (Department of Electrical Engineering, Zakir Husain College of Engineering and Technology, Aligarh Muslim University, Aligarh 202002, India)

  • Asfar Ali Khan

    (Department of Electrical Engineering, Zakir Husain College of Engineering and Technology, Aligarh Muslim University, Aligarh 202002, India)

  • Mohd Tariq

    (Department of Electrical Engineering, Zakir Husain College of Engineering and Technology, Aligarh Muslim University, Aligarh 202002, India)

  • Basem Alamri

    (Department of Electrical Engineering, College of Engineering, Taif University, Taif 21944, Saudi Arabia)

  • Lucian Mihet-Popa

    (Faculty of Information Technology, Engineering and Economics, Oestfold University College, 1757 Halden, Norway)

Abstract

The flashover performance of contaminated insulators highly depends on the type of pollutant and its present concentration. In this paper, important agricultural salts (NaCl, K 2 SO 4 , NaHCO 3 , CaSO 4 , KHCO 3 , MgSO 4 , NH 4 ), 2Fe(SO 4 ) 2 , and 6H 2 O (ferrous ammonium sulphate, dust, and urea) at different concentrations, and biological contaminants, such as algae and fungi, were taken as pollutants, and the AC flashover behavior of a porcelain-cap-and-pin-type insulator polluted with these two different pollutants was investigated. The experiment was carried out by a semi-natural method, wherein the insulator was first polluted artificially; thereafter, natural fog was applied to measure the wet flashover voltage. Test results indicated that the flashover voltages were affected by both soluble salts and non-soluble components deposited on the insulator surface. In the case of the thickly contaminated layers, non-soluble deposits greatly reduced the flashover voltage. Moreover, by using regression analysis, four empirical models based on different variables were developed. The empirical models developed in the present work represented a good degree of relation in predicting the flashover voltage of naturally contaminated insulators.

Suggested Citation

  • Shabana Khatoon & Asfar Ali Khan & Mohd Tariq & Basem Alamri & Lucian Mihet-Popa, 2022. "Flashover Voltage Prediction Models under Agricultural and Biological Contaminant Conditions on Insulators," Energies, MDPI, vol. 15(4), pages 1-14, February.
  • Handle: RePEc:gam:jeners:v:15:y:2022:i:4:p:1297-:d:746626
    as

    Download full text from publisher

    File URL: https://www.mdpi.com/1996-1073/15/4/1297/pdf
    Download Restriction: no

    File URL: https://www.mdpi.com/1996-1073/15/4/1297/
    Download Restriction: no
    ---><---

    References listed on IDEAS

    as
    1. Ang Ren & Hongshun Liu & Jianchun Wei & Qingquan Li, 2017. "Natural Contamination and Surface Flashover on Silicone Rubber Surface under Hazeā€“Fog Environment," Energies, MDPI, vol. 10(10), pages 1-18, October.
    Full references (including those not matched with items on IDEAS)

    Citations

    Citations are extracted by the CitEc Project, subscribe to its RSS feed for this item.
    as


    Cited by:

    1. Oussama Ghermoul & Hani Benguesmia & Loutfi Benyettou, 2022. "Development of a Flashover Voltage Prediction Model with the Pollution and Conductivity as Factors Using the Response Surface Methodology," Energies, MDPI, vol. 15(19), pages 1-11, September.

    Most related items

    These are the items that most often cite the same works as this one and are cited by the same works as this one.
    1. Jiazheng Lu & Pengkang Xie & Zhenglong Jiang & Zhen Fang & Wei Wu, 2018. "Voltage Distribution and Flashover Performance of 220 kV Composite Insulators under Different Icing Conditions," Energies, MDPI, vol. 11(3), pages 1-13, March.

    Corrections

    All material on this site has been provided by the respective publishers and authors. You can help correct errors and omissions. When requesting a correction, please mention this item's handle: RePEc:gam:jeners:v:15:y:2022:i:4:p:1297-:d:746626. See general information about how to correct material in RePEc.

    If you have authored this item and are not yet registered with RePEc, we encourage you to do it here. This allows to link your profile to this item. It also allows you to accept potential citations to this item that we are uncertain about.

    If CitEc recognized a bibliographic reference but did not link an item in RePEc to it, you can help with this form .

    If you know of missing items citing this one, you can help us creating those links by adding the relevant references in the same way as above, for each refering item. If you are a registered author of this item, you may also want to check the "citations" tab in your RePEc Author Service profile, as there may be some citations waiting for confirmation.

    For technical questions regarding this item, or to correct its authors, title, abstract, bibliographic or download information, contact: MDPI Indexing Manager (email available below). General contact details of provider: https://www.mdpi.com .

    Please note that corrections may take a couple of weeks to filter through the various RePEc services.

    IDEAS is a RePEc service. RePEc uses bibliographic data supplied by the respective publishers.